Clinical Trial Summary

The investigators will perform a clinical observational study of patients undergoing abdominal surgery. The study will be performed at Sykehuset Telemark, Skien. The aims of the study are to compare suprasternal and transoesophageal Doppler (reference method) to measure blood flow in the proximal descending aorta and to explore the variability of hemodynamic variables during surgery.


Clinical Trial Description

Background and aim: The best validated method to estimate cardiac output with ultrasound requires measuring the Doppler velocity time integral (VTI) in the left ventricular outflow tract measured from the apical (lateral chest) window/ projection. However, this projection is often out of reach for anaesthesiologists during many surgical procedures (e.g. abdominal surgery) due to draping, and is often difficult to perform if the patient cannot be placed in the left lateral decubitus position. Alternatively, VTI in the proximal descending aorta may be measured via the suprasternal view, which is one of the standard projections in transthoracic echocardiography. This view is often available for anaesthesiologists during surgery on a patient in supine position. Assuming that changes in cardiac output are associated with changes in VTI in proximal descending aorta, this may provide the anaesthesiologist with a non-invasive measure of the response to a fluid challenge. The first aim of this study is to evaluate the ability of suprasternal Doppler to measure blood flow in the proximal descending aorta, and its agreement with the reference method oesophageal Doppler, during ongoing abdominal surgery. Fluid challenges are typically given when stroke volume is reduced by 10-15%, which is considered a significant reduction. This is however dependent on the precision of the measurements, which is estimated during hemodynamic stability. During surgery, on the other hand, the variability may be larger, leading to erroneously concluding that stroke volume is reduced due to volume loss, when in fact this may be due to other stimuli related to surgery (mechanical, e.g. compression of large veins or the thoracic cavity, or stimuli affecting the autonomic nervous system, e.g. pain). The proportion of potentially falsely measured reduction may be calculated by performing repeated measurements during ongoing surgery. Thus, an other aim with this study is to explore the variability of measurements of stroke volume during surgery. Study design: Clinical observational study. Data collection: 30 patients scheduled to undergo laparoscopic or open abdominal surgical procedures (gastrointestinal or gynecological) of at least 1.5 hrs estimated duration. The patients should be of American Society of Anesthesiologists physical status 1-3 and have no contraindications to the use of oesophageal ultrasound. Hemodynamic data will be downloaded to a PC continuously from the clinical monitoring equipment (Philips Intellivue) using the VSCapture software (https://github.com/xeonfusion/VSCaptureMP) in VisualStudio (Microsoft). "Landmarks" in the procedure (e.g. surgical incision, manipulation in the surgical field and hemorrhage) will be recorded manually to relate the hemodynamic data to the different steps in the procedure. Blood flow velocity in the descending aorta will be measured using ultrasound machines in ordinary clinical use (GE Venue R 2.5; GE Healthcare). The Doppler recordings will be analyzed using commercially available software (EchoPAC; General Electric) after blinding. Data analyzes: - Considerations regarding sample size for agreement analyzes: The investigators will focus on within-subject variability, and the main outcome will be the corresponding within-subject limits of agreement. If both methods have a precision of 2.9%, limits of agreement will be 8.3%. Given 18 measurements per subject (one measurement every 5 min over 1.5 hrs), 25 subjects will give an 80% power for an upper confidence interval of the limits of agreement of 18%. By including 30 patients, the investigators allow for some unsuccessful measurements due to e.g. poor echogenicity. - Considerations regarding sample size for variability analyzes: Given that the SD of oesophageal Doppler is 2.9%, the precision is 2.9%×1.96=5.7%. The probability of each evaluation of showing a false reduction is 0.8%. If surgery lasts 1.5 hrs with one evaluation every 5 min, the probability of at least one false reduction is 12%. If the precision is reduced with a doubled SD, the probability of at least one false reduction is 88%. Assuming a true SD of 2.9%; studying 25 subjects gives a power of 0.8 to detect a SD <3.0%. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05227729
Study type Observational [Patient Registry]
Source Sykehuset Telemark
Contact
Status Completed
Phase
Start date October 18, 2022
Completion date January 29, 2024

See also
  Status Clinical Trial Phase
Completed NCT03653910 - Effect-site Concentration of Remifentanil for Double-lumen Tubes Intubation: Airtraq VS Macintosh Laryngoscope N/A
Completed NCT06000098 - Consol Time and Acute Kidney Injury in Robotic-assisted Prostatectomy
Recruiting NCT02565251 - Volemic Resuscitation in Sepsis and Septic Shock N/A
Terminated NCT02365688 - Hemodynamic Response During Goal Directed Fluid Therapy in the OR N/A
Completed NCT01559675 - Trial Comparing Low Dose and High Dose Steroids in Patients Undergoing Colorectal Surgery N/A
Completed NCT01605279 - Dobutamine Versus Placebo for Low Superior Vena Cava Flow in Newborns Phase 2
Recruiting NCT04010058 - Postoperative Continuous Non-invasive Haemodynamic Monitoring on the Ward N/A
Completed NCT06268275 - Comparison of Effects of Scalp Block and Intravenous Esmolol on Hemodynamic Response Following the Skull Pins Application for Elective Supratentorial Craniotomy N/A
Recruiting NCT04926220 - Dynamic Estimation of Cardiac Output in the Operating Room
Not yet recruiting NCT05003011 - Correlation of Hemodynamics Via Pulmonary Artery Catherization and the Cardiospire
Completed NCT03599440 - Effect of Extended Infusion Lines on Pulse Contour-based Measurements
Completed NCT05035485 - Maternal Cardiac Output Response to Rescue Norepinephrine and Phenylephrine Boluses in Patients With Severe Preeclampsia N/A
Not yet recruiting NCT04227821 - Hemodynamic Optimalization in Pediatric Patients
Completed NCT06158165 - Evaluating The Cardiovascular Effects of Tourniquet Application
Completed NCT05481047 - Prevention or Treatment of Arterial Hypotension and Oxygen Cerebral Saturation During Major Abdominal Surgery N/A
Not yet recruiting NCT04076709 - Cardiovascular Effects of Muscle Relaxation During Laparoscopic Surgery Phase 4
Not yet recruiting NCT03828032 - Multi-parameters'Change Process During Dehydration Therapy on Brain Edema Patients. N/A
Completed NCT04089098 - VOLume and Vasopressor Therapy in Patients With Hemodynamic instAbility
Recruiting NCT05570682 - Manually Controlled Infusion vs Target Controlled Infusion for StrokeThrombectomy N/A
Completed NCT04574908 - A Pilot Trial of Continuous Portable Postoperative Hemodynamic And Saturation Monitoring On Hospital Wards N/A