Clinical Trials Logo

Clinical Trial Summary

Evaluate the feasibility and quality of automated anesthesia, analgesia and fluid management based on a combination of several physiological variables (bispectral index [BIS], stroke volume [SV], and stroke volume variation [SVV]) using 2 independent physiologic closed-loop systems (PCLS) in patients undergoing high risk vascular surgery


Clinical Trial Description

Evaluate the feasibility and quality of automated anesthesia, analgesia and fluid management based on a combination of several physiological variables (bispectral index [BIS], stroke volume [SV], and stroke volume variation [SVV]) using 2 independent physiologic closed-loop systems (PCLS) in patients undergoing high risk vascular surgery.

All patients will receive total intravenous anesthesia in target controlled infusion mode using the population pharmacokinetic sets of Schnider for propofol and Minto for remifentanil to target the effect-site concentration. Infusion Toolbox 95 version 4.11 software (Free University of Brussels, Brussels, Belgium) implemented in a personal computer serving as a platform for: calculating effect-site concentrations of propofol and remifentanil; displaying effect-site concentration estimates in real time; providing a user interface that permits entry of patients' demographic data (sex, age, weight, and height) and modifications to target concentrations; controlling the propofol and remifentanil infusion pumps (Alaris Medical, Hampshire, United Kingdom); and recording calculated effect-site drug concentrations.

All patients will receive a baseline crystalloid infusion (PlasmaLyte, Baxter, Belgium) delivered by a pump at a rate of 3 mL/ kg/h (Fresenius Kabi, Belgium). Additional fluid was given using a goal-directed fluid therapy protocol guided by the cardiac output monitor (EV-1000; Edwards Lifesciences) and consisted of 100 mL boluses (Voluven, Fresenius Kabi, Germany) delivered by our PCLS (Learning Intravenous Resuscitator [LIR]). For fluid output, a Q-Core Sapphire Multi-Therapy Infusion Pump (Q-Core, Israel) was controlled by the LIR using software provided by Q-Core via a serial connection (Commands Server R.01). If hypotension occurred (defined as mean arterial pressure <20% of baseline blood pressure) and no fluid is delivered by the LIR, it will be treated by the anesthesiologist using a vasopressor drug.

In this pilot study, each closed loop also will operate independently, guided only by its own respective inputs (BIS for the propofol; SV and SVV for the fluid boluses).

The investigators will also measure analgesia using the PhysioDoloris monitoring device (MDoloris Medical Systems, Lille, France). ;


Study Design

Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT02886806
Study type Interventional
Source Erasme University Hospital
Contact
Status Completed
Phase Phase 1
Start date October 2016
Completion date January 2017

See also
  Status Clinical Trial Phase
Completed NCT03653910 - Effect-site Concentration of Remifentanil for Double-lumen Tubes Intubation: Airtraq VS Macintosh Laryngoscope N/A
Completed NCT06000098 - Consol Time and Acute Kidney Injury in Robotic-assisted Prostatectomy
Recruiting NCT02565251 - Volemic Resuscitation in Sepsis and Septic Shock N/A
Terminated NCT02365688 - Hemodynamic Response During Goal Directed Fluid Therapy in the OR N/A
Completed NCT01559675 - Trial Comparing Low Dose and High Dose Steroids in Patients Undergoing Colorectal Surgery N/A
Completed NCT01605279 - Dobutamine Versus Placebo for Low Superior Vena Cava Flow in Newborns Phase 2
Recruiting NCT04010058 - Postoperative Continuous Non-invasive Haemodynamic Monitoring on the Ward N/A
Completed NCT06268275 - Comparison of Effects of Scalp Block and Intravenous Esmolol on Hemodynamic Response Following the Skull Pins Application for Elective Supratentorial Craniotomy N/A
Recruiting NCT04926220 - Dynamic Estimation of Cardiac Output in the Operating Room
Not yet recruiting NCT05003011 - Correlation of Hemodynamics Via Pulmonary Artery Catherization and the Cardiospire
Completed NCT03599440 - Effect of Extended Infusion Lines on Pulse Contour-based Measurements
Completed NCT05035485 - Maternal Cardiac Output Response to Rescue Norepinephrine and Phenylephrine Boluses in Patients With Severe Preeclampsia N/A
Not yet recruiting NCT04227821 - Hemodynamic Optimalization in Pediatric Patients
Completed NCT05481047 - Prevention or Treatment of Arterial Hypotension and Oxygen Cerebral Saturation During Major Abdominal Surgery N/A
Completed NCT06158165 - Evaluating The Cardiovascular Effects of Tourniquet Application
Not yet recruiting NCT04076709 - Cardiovascular Effects of Muscle Relaxation During Laparoscopic Surgery Phase 4
Not yet recruiting NCT03828032 - Multi-parameters'Change Process During Dehydration Therapy on Brain Edema Patients. N/A
Completed NCT04089098 - VOLume and Vasopressor Therapy in Patients With Hemodynamic instAbility
Recruiting NCT05570682 - Manually Controlled Infusion vs Target Controlled Infusion for StrokeThrombectomy N/A
Completed NCT04574908 - A Pilot Trial of Continuous Portable Postoperative Hemodynamic And Saturation Monitoring On Hospital Wards N/A