End Stage Renal Disease Clinical Trial
Official title:
Outcomes of the Use of Sodium Bicarbonate (8.4%) Solution as a Catheter Lock Solution as a Catheter Lock Solution to Prevent Hemodialysis Catheter Loss Due to Lumen Clot Formation
Prospective, randomized, comparative clinical and open-label trial comparing sodium bicarbonate catheter lock solution (SBCLS) to normal saline catheter lock solution (NSCLS) use in HD patients with central venous catheters (CVC).
A randomized, comparative clinical, open-label trial at Coney Island Hospital, in Brooklyn,
NY. The study period was between October 1, 2016 and March 30, 2018, a total of 546 days. All
patients provided written informed consent before enrollment. The trial protocol was approved
by Maimonides Medical Center Investigational Review Board: Study #2015-06-25-CIH. Patients
presenting over the age of 18 requiring hemodialysis via CVCs were eligible. One patient was
excluded due to having a poor venous system with inadequate blood flow for appropriate HD. No
other patient was excluded from the study.
A total of 451 patients undergoing HD with CVCs were included in the study. Patients had
tunneled internal jugular vein (IJV) catheters, non-tunneled IJV catheters, and non-tunneled
femoral vein catheters. All patients were randomly assigned based on simple sequential order
into one of two groups: NSCLS (n = 226) and SBCLS (n = 225). NSCLS patients were assigned
between October 1, 2016 and June 30, 2017. SBCLS patients were assigned between July 1 2017
and March 30, 2018. Recruitment ended based on the similar number of enrolled participants
between groups. A primary or co-investigator enrolled the participant into the trial and
assigned the participant to the intervention at the time of presentation. Both groups
received heparin-free HD treatment. Before each HD treatment, catheters and connections were
inspected for leaks, evidence of damage, exit-site infection and tunnel infection.
Intraluminal SBCLS or NSCLS lock solution was removed before connecting the HD catheter to a
dialysis machine prior to any treatment.
During each treatment, patients were monitored for complications and standard care was
provided to every patient. After each treatment, blood was rinsed from dialysis lines with NS
solution back to the patient. Upon the conclusion of treatment, all catheters were flushed
and locked with 10 mL of NSCLS or SBCLS, respective of their groups. Approximately 2 mL of
the injected solution remained locked within the catheter. Catheter exit site dressing
changes occurred after each HD treatment.
For patients that had clotted catheters, thrombolytic therapy was not instituted. Risk
assessment performed by our hospital's risk management department determined that the net
risk of thrombolytic use in their opinion was greater than the risk of catheter replacement
by our qualified operators.
CVCs used in the study varied according to the patient's needs and consisted of Mahurkar
non-tunneled catheters and Palindrome tunneled catheters. All CVCs were inserted by an expert
operator under strict aseptic protocol. Catheter care was performed by trained dialysis staff
according to our hospital's Administrative Policy and Procedure Manual. At the end of
dialysis, all catheters were flushed and locked with one of two solutions. SBCLS contained
7.5% or 8.4% SB at a pH of 7.0-8.5, and was used to lock SBCLS-group catheters. NSCLS
contained 0.9% sodium chloride at a pH 4.5-7.0, and was used to lock NSCLS-group patient
catheters. Both are sterile non-pyrogenic solutions.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04076488 -
Feasibility of an Interactive Tablet-based Exercise Program for People With Chronical Diseases
|
N/A | |
Completed |
NCT03289650 -
Extended Release Tacrolimus vs. Twice-Daily Tacrolimus
|
Phase 3 | |
Completed |
NCT04042324 -
A Study to Investigate the Effect of Triferic Plus Heparin Infusion Compared to Heparin Alone on Coagulation Parameters in Hemodialysis Patients
|
Phase 1/Phase 2 | |
Completed |
NCT01242904 -
Use of a Bimodal Solution for Peritoneal Dialysis
|
Phase 2 | |
Active, not recruiting |
NCT03183245 -
Comparison of the Human Acellular Vessel (HAV) With Fistulas as Conduits for Hemodialysis
|
Phase 3 | |
Completed |
NCT03257410 -
Theranova 400 Dialyzer In End Stage Renal Disease (ESRD) Patients
|
N/A | |
Completed |
NCT03627299 -
Renal Transplants in Hepatitis C Negative Recipients With Nucleic Acid Positive Donors
|
Phase 4 | |
Recruiting |
NCT05917795 -
Endoscopic Sleeve Gastroplasty With Endomina® for the Treatment of Obesity in Kidney Transplant Candidates
|
N/A | |
Terminated |
NCT03539861 -
Immunomodulatory Biomimetic Device to Treat Myocardial Stunning in End-stage Renal Disease Patients
|
N/A | |
Withdrawn |
NCT02130817 -
Belatacept in Kidney Transplantation of Moderately Sensitized Patients
|
Phase 4 | |
Completed |
NCT05540457 -
Evaluation of Non-Invasive Continuous vs Intermittent BloodPressure Monitors in Maintenance Dialysis (BP Dialysis)
|
N/A | |
Not yet recruiting |
NCT04900610 -
The Effect of Vitamin K2 Supplementation on Arterial Stifness and Cardiovascular Events in PEritonial DIAlysis
|
N/A | |
Recruiting |
NCT02176434 -
Pilot Feasibility Study of Combined Kidney and Hematopoietic Stem Cell Transplantation to Cure End-stage Renal Disease
|
N/A | |
Active, not recruiting |
NCT02581449 -
Effect of Omega-3 Fatty Acids on Oxidative Stress and Dyslipidemia in Pediatric Patients Undergoing Hemodialysis
|
Phase 2 | |
Completed |
NCT02830490 -
Reliability of Functional Measures in Hemodialysis Patient.
|
N/A | |
Completed |
NCT02832466 -
Quantifying the Deterioration of Physical Function in Renal Patients
|
N/A | |
Completed |
NCT02832440 -
Comparison of Two Exercise Programmes in Patients Undergoing Hemodialysis
|
N/A | |
Completed |
NCT02134314 -
C1INH Inhibitor Preoperative and Post Kidney Transplant to Prevent DGF & IRI
|
Phase 1/Phase 2 | |
Completed |
NCT02215655 -
Increasing Autonomous Motivation in ESRD to Enhance Phosphate Binder Adherence
|
N/A | |
Recruiting |
NCT01912001 -
Virtual Ward for Home Dialysis
|
N/A |