Clinical Trials Logo

Clinical Trial Summary

The purpose of this study is to determine the frequency of prosthesis-patient mismatch after mitral valve replacement and its effect on clinical outcomes.


Clinical Trial Description

Mitral valve replacement (MVR) is associated with higher short and long term mortality than aortic valve replacement or mitral valve repair. The suboptimal results of MVR underline the importance of identifying and preventing prosthesis- patient mismatch. The effective orifice area (EOA) of prosthetic valves used for MVR is often too small in relation to body size, thus causing a mismatch between valve EOA and transvalvular flow. As a consequence, normally functioning mitral prostheses often have relatively high gradients that are similar to those found in patients with mild to moderate mitral stenosis. Residual pressure gradients across mitral prostheses delay the regression of left atrial and pulmonary arterial hypertension. Pulmonary hypertension may cause rightsided failure and is an important risk factor for morbidity and mortality in patients with cardiovascular diseases. However data about the frequency of prosthesis-patient mismatch after mitral valve replacement and its effect on clinical outcome is inconclusive. Predetermined outcomes will be evaluated in the clinical course of this condition. ;


Study Design

Observational Model: Case-Only, Time Perspective: Prospective


Related Conditions & MeSH terms


NCT number NCT00629902
Study type Observational
Source Florence Nightingale Hospital, Istanbul
Contact
Status Completed
Phase N/A
Start date February 2008
Completion date May 2008

See also
  Status Clinical Trial Phase
Not yet recruiting NCT02865798 - China Senile Valvular Heart Disease Cohort Study N/A
Completed NCT02249000 - BIOVALVE - I / II Clincial Investigation N/A
Completed NCT02297334 - Removal of Cytokines During Extracorporeal Circulation in Cardiac Surgery N/A
Completed NCT01591018 - SONOlysis in Risk REduction of Symptomatic and Silent Brain infarCtions dUring Cardiac surgEry Phase 3
Completed NCT01428947 - Does Coronary Angiography Cause Cognitive Dysfunction? N/A
Recruiting NCT01231776 - Acupuncture Improves Sleep in Patients Undergoing Cardiopulmonary Bypass N/A
Terminated NCT01116037 - ATS 3f(r) Aortic Bioprosthesis Model 1000 Post Approval Study N/A
Completed NCT00371891 - Ontario Multidetector Computed Tomographic (MDCT) Coronary Angiography Study (OMCAS) Phase 4
Terminated NCT03632967 - Early Feasibility Study of the Percutaneous 4Tech TriCinch Coil Tricuspid Valve Repair System N/A
Recruiting NCT05728047 - Evaluation of Systemic Microcirculation of Patients Undergoing Heart Valve Surgery
Not yet recruiting NCT05539261 - Research on Neurological Prognosis of Patients Undergoing Heart Valve Surgery
Completed NCT05479968 - Spectroscopic Assessment of Intramyocardial Oxygen Saturation Feasibility During Open-heart Surgery
Completed NCT03527381 - Nitric Oxide in Cardiopulmonary Bypass for Renal Protection in Cardiac Surgery Phase 1/Phase 2
Completed NCT03664102 - Automated Fastener Device Versus Manually Tied Knot in MiAVR
Recruiting NCT06084091 - Spectroscopic Assessment of Intramyocardial Oxygen Saturation During Open-Heart Surgery
Completed NCT05836467 - Is Myocardial Revascularization Really Necessary in Patients With ≥50-70% Coronary Stenosis Undergoing Valvular Surgery?
Recruiting NCT05933083 - MCNAIR Study: coMparative effeCtiveness of iN-person and teleheAlth cardIac Rehabilitation N/A
Recruiting NCT04445012 - Cardiovascular Acoustics and an Intelligent Stethoscope
Active, not recruiting NCT02732691 - JENAVALVE AS EFS TRIAL: Pericardial TAVR Aortic Stenosis Study N/A
Completed NCT02981953 - TRI-REPAIR: TrIcuspid Regurgitation RePAIr With CaRdioband Transcatheter System N/A