Clinical Trials Logo

Clinical Trial Summary

Accumulation of triglycerides in heart tissue has been associated with changes in left ventricular function which can lead to heart failure. Proton magnetic resonance spectroscopy is currently the only non-invasive in vivo method to measure myocardial triglycerides content. The primary goal of this study was to determine if Magnetic Resonance Spectroscopy could effectively measure myocardial triglyceride content in myocardial heart tissue. Thus, quantitative and reliable techniques to monitor in vivo triglyceride accumulation in the heart are important for disease diagnosis and management. Currently, no such imaging method exists.


Clinical Trial Description

Because routine biopsy of the myocardium is not feasible, MRS is the most promising technique for the quantification of myocardial triglycerides. MRS is routinely used to precisely characterize metabolite concentrations in muscle and liver. 14-16 Studies such as monitoring the levels of deoxymyoglobin and real-time tracking of the postprandial accumulation of cellular lipids are examples of its diversity and potential.15,17,18 Generally, these studies suggest that the reproducibility of MRS is between 2 and 6%.18,19 In vivo cardiac MRS provides unique challenges because of the requirement to compensate for concurrent heart and lung motion. Using cardiac and respiratory gating to minimize motional artifacts, an initial validation study found a variation of 17% for sequential measurements, attributing the major error to residual motional effects. 20 Moreover, measurements were limited to the inter-ventricular septum. Using navigator and cardiac gating appeared to give a slight, 4%, improvement, but this was a preliminary study and no validation was done.21 For a comprehensive clinical validation, other reproducibility factors must be addressed. Variations due to post-processing, coil placement and calibration, trigger reproducibility, internal versus external standard, shimming, and protocol sequence variables such as pulse quality, gradient strength, voxel size, relaxation time, echo time, and the number of scan repetitions are all known sources of reproducibility. 17,19,22-24 All of these variables must be characterized in order to achieve optimal inter- scanner and subject reproducibility along with accurate treatment tracking capability. Therefore, 10 normal healthy volunteers were imaged to determine the reliability of the MRS protocol with test-re-test measurements. The 8 heart transplant patients were imaged prior to their routine heart biopsies, and then the myocardial biopsy tissue was measure and compared to the pre-biopsy images. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT00469911
Study type Interventional
Source Washington University School of Medicine
Contact
Status Completed
Phase N/A
Start date August 2005
Completion date June 2009

See also
  Status Clinical Trial Phase
Not yet recruiting NCT06035991 - First Clinical Evaluation of Heart Transplantation With Grafts Preserved Using an Ex-vivo Extended Perfusion System N/A
Recruiting NCT01927614 - Advanced Cardiac Imaging in Cardiac Allograft Vasculopathy N/A
Recruiting NCT01705015 - Organ Transplantation Rehabilitation: Effect of Bedside Exercise Device and Activity Reinforcement N/A
Completed NCT01655563 - Pharmacogenetic Trial of Tacrolimus After Pediatric Transplantation Phase 2
Completed NCT01028599 - Effect of Physical Training on Oxygen Uptake and Endothelial Function in Heart Transplant Recipients N/A
Completed NCT00531921 - Effects of Donor and Recipient Genetic Expression on Heart, Lung, Liver, or Kidney Transplant Survival N/A
Terminated NCT00420537 - Shift to Everolimus (RAD) Kidney Sparing Study Phase 4
Enrolling by invitation NCT03292861 - The Effect and Safety Profile of Thymoglobulin® in Primary Cardiac Transplant Recipients Phase 2
Recruiting NCT04924491 - Cell Therapy With Treg Cells Obtained From Thymic Tissue (thyTreg) to Prevent Rejection in Heart Transplant Children Phase 1/Phase 2
Recruiting NCT05270902 - Haemoadsorption During Heart Transplantation N/A
Completed NCT05289180 - Brachial Right Ventricle - Endomyocardial Biopsy
Recruiting NCT03687723 - Observational Study of the Clinical Use of the OCS™ Heart
Completed NCT01091194 - Effect of Exercise After Heart Transplantation Phase 2
Withdrawn NCT00780637 - Brachial Artery t-PA Release in Heart Transplant Recipients N/A
Withdrawn NCT00780377 - Intracoronary Bradykinin Mediated t-PA Release in Heart Transplant Recipients N/A
Terminated NCT00678002 - Quality of Life in Pediatric Transplant Patients
Completed NCT01182571 - Exploration of Fatigue, Uncertainty, Depression and Quality of Life in Heart Transplantation Recipients N/A
Terminated NCT00121784 - Heart Spare the Nephron (STN) Study - A Study of CellCept (Mycophenolate Mofetil) and Rapamune (Sirolimus) in Heart Transplant Recipients Phase 4
Withdrawn NCT00572286 - Non-invasive Evaluation of Heart Transplant Rejection- Pilot Study N/A
Completed NCT00690157 - Registry of Patients Referred for Heart Transplantation N/A