Study protocol To prepare for the electrophysiologic study, antiarrhythmic drugs were discontinued at least five half-lives before the procedure and were under conscious sedation using midazolam ± fentanyl while fasting. ICE-guided ablation group In patients randomized to ICE-guided ablation group, catheter placement was initially performed using fluoroscopy guidance, after local anesthesia. A decapolar steerable catheter was placed in the coronary sinus (CS), a quadripolar electrode catheter was positioned in the right ventricular apex and an ablation catheter was inserted to record the His bundle electrogram. Twelve-lead electrocardiogram and intracardiac electrograms were recorded and saved on a digital recording system using a band pass filter of 30 to 500 Hz. Electrical stimulation techniques were used to test atrioventricular nodal conduction and induce AVNRT, with the S2 coupling interval being gradually shortened after each drive-train until tachycardia was induced, AV conduction block occurred, or the atrial refractory period was reached. If tachycardia was not inducible, isoprenaline infusion was given to increase the heart rate by at least 20%, and the same stimulation protocol was repeated during both the infusion and washout phases. The diagnosis of AVNRT was made using established electrophysiologic criteria and pacing maneuvers. This involved assessing the A-(H)-V response after ventricular overdrive pacing, with an SA-VA interval greater than 85 ms, and a corrected postpacing interval minus tachycardia cycle length greater than 110 ms. After confirmation of the diagnosis of AVNRT through the diagnostic EP study, the quadripolar electrode catheter was removed and replaced with an 8F ICE catheter for mapping and SP ablation. The echo-transducer was positioned in the low right atrium at the 6 o'clock position and rotated clockwise towards the septum to allow for visualization of the anatomic landmarks. The proximity of the ablation catheter to the compact AV node was determined by the distance from the aortic valve, which marks the recording site of a proximal His potential. In cases of ineffective ablation, the catheter was moved closer to the aortic valve, but always maintaining a distance of at least 0.5 cm, and RF application was attempted again. RF energy was delivered starting just below the CS with a power output of 30 W and a preset temperature of 55°C. Effective applications were continued for 30 to 60 s and considered successful when junctional rhythm appeared. RF application was immediately halted if there was catheter displacement, sudden impedance rise, prolongation of PR interval, anterograde AV or retrograde VA block. Electroanatomical mapping system -guided ablation group An ablation catheter was inserted into the heart to create an anatomical map by CARTO of the right atrium after local anesthesia, and the location of the His bundle was tagged. Decapolar and quadripolar diagnostic catheters were positioned thereafter into appropriate position as described above. After confirming the diagnosis of AVNRT, mapping of the slow pathway was started by NAVISTAR catheter guided by EAMS and aiming at an atrial-to-ventricular electrogram amplitude ratio of 1:3-1:5. If the ablation endpoint was not reached after 8 radiofrequency (RF) applications, patients in the EMAS-guided ablation group were allowed to crossover to an ICE-guided procedure. The ablation procedure was deemed successful if, following a 20-minute waiting period, the arrhythmia failed to be induced and there were no instances of more than one echo beat observed, both in the presence and absence of isoprenaline. The procedure time was measured from the initial femoral puncture until the withdrawal of the catheters. The mapping plus ablation time was calculated from the start of the SP mapping until the end of the last attempted ablation. Fluoroscopy time, radiation dose, and dose-area product (DAP) were automatically recorded by the fluoroscopy system. The ablation data, including the total number of RF applications, sum of delivered RF energy in Watts, and the total ablation time in seconds, were calculated and stored by the EP recording system (CardioLab, GE Healthcare).


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT05907863
Study type Interventional
Source University of Pecs
Contact
Status Completed
Phase Phase 4
Start date April 1, 2022
Completion date April 1, 2023

See also
  Status Clinical Trial Phase
Completed NCT04621032 - Obstructive Sleep Apnea Destabilizes Myocardial Repolarization Homogeneity
Recruiting NCT05473702 - Smart Textile Sensor System for Health Monitoring
Completed NCT04818697 - Effect of Social Isolation on Physical Activity Level, and Kinesophobia in Heart Rhythm Disorders During Pandemic
Not yet recruiting NCT06128980 - Withdrawal of Treatment for Heart Failure Patients With Recovery From Tachycardia-induced Cardiomyopathy Phase 2/Phase 3
Completed NCT04391439 - Heart Rhythm After Intravenous Methylprednisolone Administration
Completed NCT03842020 - Pharmacokinetics of Amiodarone in Children N/A