Hearing Loss Clinical Trial
Official title:
Evaluation of the Changes in Cochlear Implant Patients Care Pathway With the Use of Telemonitoring
Following a sufficient delay after the cochlear implantation and initial implant activation, the patient will return to the hospital for follow-up visits for equipment maintenance and auditory performance evaluation only once per year. This frequency might appear either insufficient, in which case an additional patient check-up will be arranged, or excessive if patient performances and implant adjustments are stable. Using at-home testing tool for remote hearing performance monitoring can thus appear advantageous for both patients and clinicians, allowing to avoid an unnecessary journey to the implantation reference center for the first and to diminish a number of unscheduled medical appointments for the second.
In December 2020, the French Medical Device and Health Technology Evaluation Committee (CNEDiMTS) voted in favour of the integration of telemonitoring in cochlear implant users' follow-up thus adding a range of new possibilities to a standard health care routine. According to the official recommendations of the French National Authority for Health, a patient implanted for a sufficiently long time should be seen annually at the implantation reference center. This periodicity might appear too low, in which case a patient will have to organise an unscheduled check-up appointment. Such appointments are a source of various problems: firstly, they disorganise the routine of the reference centers not adapted for emergency and semi-emergency situations; secondly, the patient might encounter substantial travelling fees (only 22 refence centers in France), especially if an implant component to replace is out of stock. Having an utility of remote patient monitoring is also beneficial in situations where the access to health care system is restricted, for example, the recent pandemic of Covid 19. Cochlearâ„¢ has recently designed an at-home based patient testing tool, Remote Check application, permitting to complete a series of hearing test from a compatible smartphone. The results are then sent to the implantation reference center and evaluated by healthcare professionals. The data is securely stored on Cloud accessible to authorised clinicians via MyCochlear site. Although the feasibility and the accuracy in detecting technical problems of remote follow-up of people with cochlear implant had been already assessed, its impact on health care system is still unknown. Hence, this project will be the first to evaluate an interest of implementing remote monitoring in following adults with cochlear implantation. The main objective of the study is - to determine if the use of telemonitoring through Remote Check application reduces significantly a number of unscheduled check-up appointments in the reference centre during 1 year follow-up period for a patient with a cochlear implant Cochlearâ„¢ in comparison to traditional health care approach. The secondary objectives are: - To compare a number of scheduled appointments during a period of Remote Check use versus a historical period of a traditional follow-up - To compare a number of indispensable unscheduled visits (unavoidable with or without Remote Check use) with a number of unnecessary ones (avoidable with Remote Check) - To measure the compliance of the Remote Check application use - To assess quantitatively and qualitatively a number of implant failures/dysfunctions identified with Remote Check - To evaluate for each study participant time spent by clinician to treat Remote Check analysis data uploaded to My Cochlear data base - To assess patients satisfaction of Remote Check implementation in their healthcare routine - To evaluate the quality of life specific to the Deaf before and after Remote Check use The study implies four visits for each patient. The inclusion visit (V0) is a routine check-up appointment in the implantation reference center. After the patient is informed and his/her consent is collected, the Remote Check application will be activated on his/her processor. Two next follow-up visits, V1 (V0+ 5 mois (± 0.5 mois)) and V2 (V0 + 11 mois (± 0.5 mois)), are remote visits with hearing test performed through Remote Check application. Final visit, V3 (V0 + 12 mois (± 0.5 mois)), corresponds to patient's annual check-up appointment. In case a problem with processor's functioning is detected during V2, it will be resolved at V3. Equipment verification will be also performed to detect failures missed by Remote Check. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04696835 -
fNIRS in Pediatric Hearing Aids
|
N/A | |
Completed |
NCT03662256 -
Reducing Childhood Hearing Loss in Rural Alaska Through a Preschool Screening and Referral Process Using Mobile Health and Telemedicine
|
N/A | |
Completed |
NCT04602780 -
Evaluating the Revised WORQ in CI Users
|
||
Completed |
NCT03723161 -
Evaluation of the Ponto Bone Anchored Hearing System in a Pediatric Atresia Population
|
||
Completed |
NCT05086809 -
Investigation of an Updated Bone-anchored Sound Processor
|
N/A | |
Active, not recruiting |
NCT03548779 -
North Carolina Genomic Evaluation by Next-generation Exome Sequencing, 2
|
N/A | |
Completed |
NCT03428841 -
Audiovisual Assessment After Dural Puncture During Epidural Placement in Obstetric Patients
|
N/A | |
Completed |
NCT04559282 -
Home Test of New Sound Processor
|
N/A | |
Enrolling by invitation |
NCT03345654 -
Individually-guided Hearing Aid Fitting
|
||
Completed |
NCT06016335 -
MRI-based Synthetic CT Images of the Head and Neck
|
N/A | |
Completed |
NCT05165121 -
Comparison of Hearing Aid Fitting Outcomes Between Self-fit and Professional Fit for MDHearing Smart Hearing Aids
|
N/A | |
Recruiting |
NCT05533840 -
Establishment and Application of a New Imaging System for Otology Based on Ultra-high Resolution CT
|
||
Terminated |
NCT02294812 -
Effects of Cognitive Training on Speech Perception
|
N/A | |
Completed |
NCT04622059 -
AUditive Direct In-utero Observation (AUDIO): Prenatal Testing of Congenital Hypoacusis
|
N/A | |
Recruiting |
NCT02558478 -
Identification of New Genes Implicated in Rare Neurosensory Diseases by Whole Exome Sequencing
|
N/A | |
Withdrawn |
NCT02740322 -
Validating the Hum Test
|
N/A | |
Completed |
NCT01963104 -
Community-Based Kiosks for Hearing Screening and Education
|
N/A | |
Completed |
NCT01892007 -
Evaluation of Cogmed Working Memory Training for Adult Hearing Aid Users
|
N/A | |
Completed |
NCT01857661 -
The Influence of the Sound Generator Combined With Conventional Amplification for Tinnitus Control: Blind Randomized Clinical Trial
|
N/A | |
Withdrawn |
NCT01223638 -
The Prevalence of Hearing Loss Among Children With Congenital Hypothyroidism
|
N/A |