Hearing Loss Clinical Trial
Official title:
Long-term Follow-up of a Wide Diameter Bone Anchored Hearing Implant: the 10-year Experience on Stability, Survival and Tolerability of the BIA300®
Verified date | September 2021 |
Source | Radboud University |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
A single centre, open, comparative, parallel group, prospective clinical investigation with a single 10 year follow up visit.
Status | Completed |
Enrollment | 51 |
Est. completion date | September 21, 2020 |
Est. primary completion date | September 21, 2020 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years and older |
Eligibility | Inclusion Criteria: - To be included in the original trials, patients had to be at least 18 years old. Exclusion Criteria: - Exclusion criteria were an inability to follow investigational procedures, any factor at the discretion of the investigator that was considered to contraindicate participation, and any disease or treatment known to compromise the bone quality at the implant site. For patients who had lost or removed the implant, the time to implant loss was recorded. Patients who could not attend the 5 or 10 year follow-up visit for other reasons were included in the implant survival analysis as well; the last available information regarding implant survival was obtained verbally from the patient, from medical records, or from information captured from the original investigations. Furthermore, patients were excluded if they had a bone thickness less than 4 mm at the implant site during implantation. |
Country | Name | City | State |
---|---|---|---|
Netherlands | Radboudumc | Nijmegen | Gelderland |
Lead Sponsor | Collaborator |
---|---|
Radboud University | Cochlear Bone Anchored Solutions |
Netherlands,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | implant stability | Implant Stability Quotiënt (ISQ) will be measured at the 10y-visit. The resonance frequency analysis renders an ISQ value ranging from 1 to 100. Measurements shall be performed at the abutment level, as is done in the previous investigations. The highest and lowest ISQ value out of two perpendicular measurements shall be recorded as ISQ High and ISQ low. The measurement should preferably be done by the same Osstell instrument (Osstell, Gothenburg, Sweden) that was used in the previous completed study. SmartPeg Type 43 and 55 shall be used during the measurement (Osstell, Gothenburg, Sweden). The procedures for obtaining ISQ values is described in the manufacturer's instruction that will be handed out to the investigators. | 10 years after implantation | |
Secondary | implant survival | All patients will be asked if they have experienced any implant osseointegration problems. The time from implantation until implant loss or removal will be noted. In case of implant removal, reason for removal shall be recorded. | 10 years after implantation | |
Secondary | soft tissue reaction | Soft tissue reactions will be measured using the Holgers' classification & IPS-score.
The Holgers' classification is designed to capture signs and symptoms of inflammation or infection at the site of implantation (scale 0-4). The IPS-score is a complete standardized assessment scale for skin complications for both percutaneous and transcutaneous implants for bone conduction devices (BCDs) with a proposed treatment advice based on the outcome. The IPS score has three subscales: inflammation (0-4); pain (0-2), and skin height (0-2). |
10 years after implantation | |
Secondary | device use | To evaluate the long-term device use of a Baha®. | 10 years after surgery |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04696835 -
fNIRS in Pediatric Hearing Aids
|
N/A | |
Completed |
NCT03662256 -
Reducing Childhood Hearing Loss in Rural Alaska Through a Preschool Screening and Referral Process Using Mobile Health and Telemedicine
|
N/A | |
Completed |
NCT04602780 -
Evaluating the Revised WORQ in CI Users
|
||
Completed |
NCT03723161 -
Evaluation of the Ponto Bone Anchored Hearing System in a Pediatric Atresia Population
|
||
Completed |
NCT05086809 -
Investigation of an Updated Bone-anchored Sound Processor
|
N/A | |
Active, not recruiting |
NCT03548779 -
North Carolina Genomic Evaluation by Next-generation Exome Sequencing, 2
|
N/A | |
Completed |
NCT03428841 -
Audiovisual Assessment After Dural Puncture During Epidural Placement in Obstetric Patients
|
N/A | |
Completed |
NCT04559282 -
Home Test of New Sound Processor
|
N/A | |
Enrolling by invitation |
NCT03345654 -
Individually-guided Hearing Aid Fitting
|
||
Completed |
NCT06016335 -
MRI-based Synthetic CT Images of the Head and Neck
|
N/A | |
Completed |
NCT05165121 -
Comparison of Hearing Aid Fitting Outcomes Between Self-fit and Professional Fit for MDHearing Smart Hearing Aids
|
N/A | |
Recruiting |
NCT05533840 -
Establishment and Application of a New Imaging System for Otology Based on Ultra-high Resolution CT
|
||
Completed |
NCT04622059 -
AUditive Direct In-utero Observation (AUDIO): Prenatal Testing of Congenital Hypoacusis
|
N/A | |
Terminated |
NCT02294812 -
Effects of Cognitive Training on Speech Perception
|
N/A | |
Recruiting |
NCT02558478 -
Identification of New Genes Implicated in Rare Neurosensory Diseases by Whole Exome Sequencing
|
N/A | |
Withdrawn |
NCT02740322 -
Validating the Hum Test
|
N/A | |
Completed |
NCT01963104 -
Community-Based Kiosks for Hearing Screening and Education
|
N/A | |
Completed |
NCT01892007 -
Evaluation of Cogmed Working Memory Training for Adult Hearing Aid Users
|
N/A | |
Completed |
NCT01857661 -
The Influence of the Sound Generator Combined With Conventional Amplification for Tinnitus Control: Blind Randomized Clinical Trial
|
N/A | |
Withdrawn |
NCT01223638 -
The Prevalence of Hearing Loss Among Children With Congenital Hypothyroidism
|
N/A |