Clinical Trials Logo

Clinical Trial Summary

Hearing loss is among the top service-connected disabilities in Veterans. Hearing aids are the primary intervention for hearing loss. Half of the hearing aids dispensed in the VA are to Veterans who are receiving replacement amplification. Many Veterans would like their replacement hearing aids mailed to them, but they are required to travel to the clinic so that the fit of the hearing aid can be verified. There are standard fitting procedures, such as those used in infants and children, that use a coupler to simulate the patient's real ear to verify the hearing aid fitting. The results of this study should determine the efficacy of a coupler-based hearing-aid fitting protocol that would not require the Veteran to attend the fitting appointment, thereby contributing to improved Veteran-Centric care.


Clinical Trial Description

In the VA system, hearing loss is the second-most common service-connected condition affecting 933,182 Veterans, exceeded only by tinnitus which affects 1,121,709 Veterans (data from Veterans Benefit Report for Fiscal Year 2016). In FY 2016, the VA dispensed 750,075 hearing aids at a net procurement of nearly $270 million (report generated from VA Denver Acquisition and Logistics Center [DALC] Remote Order Entry System [ROES]). Half of the hearing aids dispensed were to experienced hearing aid users receiving replacement hearing aids (Dennis, 2014). VA Audiology caseload is significant and Veterans can experience long wait-times for fitting appointments to obtain new hearing aids (Office of the Inspector General, 2014). The purpose of the fitting appointment is to program and verify the hearing aids and orient the patient to hearing aid use/care. For patients obtaining replacement hearing aids, the orientation typically is unnecessary, and the programming is simplified; consisting mainly of matching the individual's real-ear aided response (REAR) and hearing aid output to appropriate target values. In contrast to adults, REAR measurements are not well-tolerated by children due to the requirement for placement of a probe tube in the ear canal. Therefore, a hearing aid fitting procedure that circumvents the need for in situ REAR measurements (real ear coupler difference or RECD) is the standard-of-care (SoC) for children. Considerable research clearly has shown the equivalency of in situ REAR and RECD fitting procedures (e.g., Moodie et al., 1994). RECD fitting procedures rarely are used with adults; however, such an approach could preclude the need for direct physical contact with the patient at the time of the hearing aid fitting. Three experiments are proposed. The purpose of the first study is to evaluate coupler-based fitting approach for groups of experienced users obtaining replacement hearing aids and compare the accuracy of those fittings to the prescription and their outcomes to norms. The second study aims to develop correction factors for venting of open-fit hearing aids. The third study will focus on comparing coupler-based fittings of open-fit hearing aids (using correction factors developed from study two results) to an SoC (active control) group who will have their open-fit hearing aids fitted in face-to-face appointment via standard in situ REAR procedures. In Study 1 and 3, both groups will return for in situ REARs and self-report outcomes assessment one month after the hearing-aid fitting. The results of this study should determine the efficacy of a RECD-based, hearing-aid fitting approach for experienced hearing-aid users who are receiving replacement hearing aids consisting of a variety of styles. If the approaches are equivalent, then this study will provide an evidence-based, RECD fitting approach that should result in greater patient satisfaction and reduced costs. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03569228
Study type Interventional
Source VA Office of Research and Development
Contact
Status Active, not recruiting
Phase N/A
Start date October 28, 2019
Completion date December 31, 2023

See also
  Status Clinical Trial Phase
Recruiting NCT04696835 - fNIRS in Pediatric Hearing Aids N/A
Completed NCT03662256 - Reducing Childhood Hearing Loss in Rural Alaska Through a Preschool Screening and Referral Process Using Mobile Health and Telemedicine N/A
Completed NCT04602780 - Evaluating the Revised WORQ in CI Users
Completed NCT03723161 - Evaluation of the Ponto Bone Anchored Hearing System in a Pediatric Atresia Population
Completed NCT05086809 - Investigation of an Updated Bone-anchored Sound Processor N/A
Active, not recruiting NCT03548779 - North Carolina Genomic Evaluation by Next-generation Exome Sequencing, 2 N/A
Completed NCT03428841 - Audiovisual Assessment After Dural Puncture During Epidural Placement in Obstetric Patients N/A
Completed NCT04559282 - Home Test of New Sound Processor N/A
Enrolling by invitation NCT03345654 - Individually-guided Hearing Aid Fitting
Completed NCT06016335 - MRI-based Synthetic CT Images of the Head and Neck N/A
Completed NCT05165121 - Comparison of Hearing Aid Fitting Outcomes Between Self-fit and Professional Fit for MDHearing Smart Hearing Aids N/A
Recruiting NCT05533840 - Establishment and Application of a New Imaging System for Otology Based on Ultra-high Resolution CT
Completed NCT04622059 - AUditive Direct In-utero Observation (AUDIO): Prenatal Testing of Congenital Hypoacusis N/A
Terminated NCT02294812 - Effects of Cognitive Training on Speech Perception N/A
Recruiting NCT02558478 - Identification of New Genes Implicated in Rare Neurosensory Diseases by Whole Exome Sequencing N/A
Withdrawn NCT02740322 - Validating the Hum Test N/A
Completed NCT01963104 - Community-Based Kiosks for Hearing Screening and Education N/A
Completed NCT01892007 - Evaluation of Cogmed Working Memory Training for Adult Hearing Aid Users N/A
Completed NCT01857661 - The Influence of the Sound Generator Combined With Conventional Amplification for Tinnitus Control: Blind Randomized Clinical Trial N/A
Withdrawn NCT01223638 - The Prevalence of Hearing Loss Among Children With Congenital Hypothyroidism N/A