Clinical Trials Logo

Clinical Trial Summary

Currently, the fitting of hearing aids is using a computer interface that allows to adjust the gain and compression of acoustic amplification. This adjustment is made face to face, patient and audiologist being located in a soundproof space to test the effectiveness of the hearing aid.

However, advances in telemedicine in this context, let consider the possibility of addressing these hearing aids fitting via the same computer interface, but remotely controlled by the hearing care professional. The purpose of this study is to assess the ability to perform these tests no longer in front of the patient settings, but away from it, and without visual and sound contact other than through a computer interface.

At the end, this project wants to show that a remote fitting is an acceptable procedure that provides comparable results to-face fitting in terms of speech perception, speech in noise audiometry, hearing loss related quality of life in order to be able to offer this type of strategy.


Clinical Trial Description

1. Background and rationale:

Currently, the fitting of hearing aids is using a computer interface that allows to adjust the gain and compression of acoustic amplification. This adjustment is made face to face, patient and audiologist being located in a soundproof space to test the effectiveness of the hearing aid.

However, advances in telemedicine in this context, let consider the possibility of addressing these hearing aids fitting via the same computer interface, but remotely controlled by the hearing care professional. The purpose of this study is to assess the ability to perform these tests no longer in front of the patient settings, but away from it, and without visual and sound contact other than through a computer interface.

2. Objectives Main objective: To show that the remote fitting of hearing aids using the platform developed by AudioProConnect provides speech perception scores similar to those obtained by a face-control, after 5 weeks of use among experienced hearing aid users.

Secondary Objectives: To compare the duration and the quality of both types of fitting, speech in noise testing, deafness related quality of life and assess the wearing time of hearing aids.

3. Methods DESIGN: Biomedical research on health product, prospective, multicenter, randomized, and crossover study to assess the remote fitting of hearing aids: Study REFIT-HEARING Study Population: adults with bilateral hearing aids. Inclusion criteria: Patient aged between 18 and 85 years old, with hearing loss and using two hearing aids for more than one year, and compatible with AudioProConnect platform.

Exclusion criteria: Patient with fluctuations of pure tone audiometry, cognitive disorders or severe speech disorders. Patient unable to move in an audiology laboratory.

Primary Outcome: Evaluation of speech perception score with PBK test free-field at 60 dB.

Secondary endpoints: assessment of quality control by measuring the pitch gain, duration of fitting in minutes, speech in noise audiometry, the wearing time of hearing aids in hours, the quality of life related to hearing loss via the APHAB questionnaire.

Number of patients: 60 subjects Procedure (number of visits, length of inclusions, duration of follow-up, study schedule patient visits content, brief description of intervention): After the investigator has verified the criteria of inclusion / non inclusion and the subject has signed the written informed consent, the subject will be followed for a period ranging from 2 months to 5 months, during which he attended four visits in a audiology laboratory referenced in this project. During these visits, a fitting of hearing aids face to face or remotely will be realized, and it will be asked to answer a questionnaire to assess quality of life between the two fitting techniques.

Study Schedule:

Inclusion period: 3 months (M3-M6) Duration of the study for one subject: 2 months to 5 months (M6 to M8 or M6 to M11) Duration statistical analysis / recovery: 3 months (M11-M14) Global Study duration: 14 months

4. Outlook At the end, this project wants to show that a remote fitting provides comparable results to-face fitting in terms of speech perception, in order to be able to offer this type of strategy. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02589561
Study type Interventional
Source University Hospital, Montpellier
Contact
Status Completed
Phase N/A
Start date October 2015
Completion date December 2016

See also
  Status Clinical Trial Phase
Recruiting NCT04696835 - fNIRS in Pediatric Hearing Aids N/A
Completed NCT03662256 - Reducing Childhood Hearing Loss in Rural Alaska Through a Preschool Screening and Referral Process Using Mobile Health and Telemedicine N/A
Completed NCT04602780 - Evaluating the Revised WORQ in CI Users
Completed NCT03723161 - Evaluation of the Ponto Bone Anchored Hearing System in a Pediatric Atresia Population
Completed NCT05086809 - Investigation of an Updated Bone-anchored Sound Processor N/A
Active, not recruiting NCT03548779 - North Carolina Genomic Evaluation by Next-generation Exome Sequencing, 2 N/A
Completed NCT03428841 - Audiovisual Assessment After Dural Puncture During Epidural Placement in Obstetric Patients N/A
Completed NCT04559282 - Home Test of New Sound Processor N/A
Enrolling by invitation NCT03345654 - Individually-guided Hearing Aid Fitting
Completed NCT06016335 - MRI-based Synthetic CT Images of the Head and Neck N/A
Completed NCT05165121 - Comparison of Hearing Aid Fitting Outcomes Between Self-fit and Professional Fit for MDHearing Smart Hearing Aids N/A
Recruiting NCT05533840 - Establishment and Application of a New Imaging System for Otology Based on Ultra-high Resolution CT
Terminated NCT02294812 - Effects of Cognitive Training on Speech Perception N/A
Completed NCT04622059 - AUditive Direct In-utero Observation (AUDIO): Prenatal Testing of Congenital Hypoacusis N/A
Recruiting NCT02558478 - Identification of New Genes Implicated in Rare Neurosensory Diseases by Whole Exome Sequencing N/A
Withdrawn NCT02740322 - Validating the Hum Test N/A
Completed NCT01963104 - Community-Based Kiosks for Hearing Screening and Education N/A
Completed NCT01892007 - Evaluation of Cogmed Working Memory Training for Adult Hearing Aid Users N/A
Completed NCT01857661 - The Influence of the Sound Generator Combined With Conventional Amplification for Tinnitus Control: Blind Randomized Clinical Trial N/A
Withdrawn NCT01223638 - The Prevalence of Hearing Loss Among Children With Congenital Hypothyroidism N/A