Clinical Trials Logo

Clinical Trial Summary

Overhearing is important for vocabulary learning and speech and language development in young children. However, contemporary hearing aids are generally unable to provide adequate access to low-level auditory inputs from multiple talkers at a distance to capitalize on overhearing. A recent investigation by Jace Wolfe and colleagues showed that, even when aided, children with hearing loss had significantly poorer speech recognition at 40, 50 and 60 dBA compared to children with normal hearing. Furthermore, they showed that increasing hearing aid gain for very low-level inputs produced a statistically significant improvement in syllable-final plural recognition and a non-significant trend toward better monosyllabic word recognition at very low presentation levels. Additional research is needed to document low-level speech recognition ability of children with hearing loss as well as the potential benefit or detriment of increasing hearing aid gain for low-level inputs. A novel hearing aid technology known as Soft Speech Enhancer has been shown improve low-level speech perception in adults with hearing loss; however, the effect of Speech Enhancer on speech recognition in children is not yet known and will be evaluated.


Clinical Trial Description

The primary objective of this study is to evaluate whether soft speech recognition in quiet is significantly improved with Speech Enhancer (SE) "on" at the default setting (moderate) compared to Speech Enhancer "off" in children with moderate (N3) to severe (N5) hearing loss. There are several secondary objectives: 1) To evaluate the main effects of age and Speech Enhancer strength, and potential interaction on speech recognition and comfort in children with moderate to severe hearing loss. 2) To demonstrate that hearing aids compensate for hearing loss in children. This confirmatory clinical investigation will be executed at Hearts for Hearing. It is a single-group, single blind intervention study with each participant serving as his or her own control. However, in certain conditions participant blinding is not feasible (i.e., aided versus unaided performance). The outcome measures being assessed include: speech recognition in quiet with Consonant-Nucleus-Consonant (CNC) words, and comfort ratings using a Multiple Stimuli with Hidden Reference and Anchor (MUSHRA) procedure and looped sentences overlaid with low-level transient noise. Four different hearing aid conditions will be assessed in this clinical investigation: unaided (no amplification), aided with SE "off", aided with SE "moderate", aided with SE "strong". For the unaided or no treatment condition no hearing aids will be worn. For aided conditions, experienced hearing aid users will be fit binaurally with investigational devices matching their personal device form factor connected to their personal acoustic coupling (e.g., earmold). Using the Audioscan Verifit 2, probe microphone measurements will be conducted to match DSL 5.0 pediatric quiet and noise targets. Three distinct programs will be created, each with a different SE strength. Hearing aid program order (speech enhancer settings) will be randomized for all testing conditions except for CNC at 50 dBA Quiet with SE Off; that condition is administered first to establish candidacy for further testing. A randomized list of SE settings was generated for all participants for the remaining conditions. Testing will be completed in a double-walled sound booth with calibrated equipment. Recorded stimuli will be presented through loudspeakers (Sony CFD-ZW755) from clinical audiometers (Grayson Stadler Standard) or Dell computers using the Arizona State University Speech Recognition Program, Windows Media Player and Adobe Audition. Speech stimuli will be presented from a loudspeaker located at 0 degrees azimuth (directly in front). Speech recognition results will be compared to determine the effect of amplification on accuracy scores as well as the influence of speech enhancer on behaviorally measured benefit and subjectively-derived listening preference. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05299892
Study type Interventional
Source Sonova AG
Contact
Status Completed
Phase N/A
Start date March 21, 2022
Completion date October 14, 2022

See also
  Status Clinical Trial Phase
Completed NCT04281953 - Impact on Quality of Life of Long-term Ototoxicity in Cancer Survivors
Completed NCT04601909 - FX-322 in Adults With Age-Related Sensorineural Hearing Loss Phase 1
Active, not recruiting NCT04479761 - Sensory Integration of Auditory and Visual Cues in Diverse Contexts N/A
Recruiting NCT05043207 - A Study Protocol for the Validation of UAud in a Clinical Setting. N/A
Recruiting NCT04070937 - Correlation of Radiological Lesions With Vestibular Function in Patients With Bilateral Vestibulopathy
Recruiting NCT04066270 - Inventory of Radiological and Vestibular Function in Cochlear Implant Candidates
Completed NCT03512951 - Subjective Evaluation of a Sound Processing Method for Hearing Aids on Auditory Distance Perception N/A
Active, not recruiting NCT05855005 - Direct-to-Consumer Hearing Aids and Listening Effort N/A
Recruiting NCT05599165 - Speech Perception in Bimodal Hearing N/A
Completed NCT05101083 - Speech Intelligibility in Quiet and Noise for New vs. Legacy Hearing Aids N/A
Completed NCT05521308 - Investigating Hearing Aid Frequency Response Curves N/A
Completed NCT05072457 - Benefit of Assistive Listening Device for Lateralization N/A
Recruiting NCT05776459 - Efficacy and Safety of AC102 Compared to Steroids in Adults With Idiopathic Sudden Sensorineural Hearing Loss (ISSNHL) Phase 2
Completed NCT05086276 - FX-322 in Adults With Acquired Sensorineural Hearing Loss Phase 2
Recruiting NCT06058767 - Preschool Hearing Screening N/A
Completed NCT05180630 - Sound Quality Comparisons With Different Hearing Aid Couplings and Venting Systems N/A
Completed NCT03613909 - Acceptance of the CP950 Sound Processor N/A
Active, not recruiting NCT03352154 - Long Latency Auditory Evoked Potentials (P300) Outcomes in Patients With Unilateral Cochlear Implants N/A
Completed NCT04629664 - FX-322 in Adults With Severe Sensorineural Hearing Loss Phase 1
Completed NCT05052944 - Single-sided Deafness and Cochlear Implantation