Clinical Trial Summary

The study is a prospective, multi-center, single arm study The study is part of the Post Market Clinical Follow (PMCF) activity. The investigational device used in this study is the Ponto 4 already fitted to the subjects prior to the study. The device is CE marked and available on the market since June 2019. Treatment is not provided in the study therefore risks are limited to the audiological measurements. The audiological measurements in the study are standard non-invasive measurements already familiar to the clinics. The hearing with Ponto 4 will be evaluated via speech and hearing tests, and patient reported outcomes.


Clinical Trial Description

This is a post market clinical follow up (PMCF) study with the purpose of gather knowledge on the use and performance of the Ponto 4 device on existing Ponto 4 users. The study does not include any treatment or fitting of new devices, instead the real-life application of the use of Ponto 4 on subjects already using Ponto 4(s) are investigated. The Investigational Device used in the study is Ponto 4, a CE marked, and FDA cleared bone anchored hearing solution, produced by Oticon Medical AB and commercially available since June 2019. The recruitment for this clinical investigation will be performed among subjects who have already received a Ponto 4 device as a minimum 1.5 month prior to the study. 20 patients, including minors down to 12 years old, with a conductive, mixed hearing loss or single-sided deafness will be included. The rationale for including minors is that they are also users of the device, and it is found important to collect data from their experience of using the device as well. The study is a prospective, multi-center study. It has one visit of 2,5-3 hours for adult subjects ≥18 years old. To minimize the burden and risks of tiredness for the minor subjects from 12-17 years old, the protocol activities can be divided into two visits. The decision will be based on the Investigators discretion. The majority of the objectives of the study are prospectively collected whereas the BC In-situ (hearing with the Ponto 4 on) and audiometric data from the time of the fitting of Ponto 4, are collected retrospectively from the time of the fitting of Ponto 4. The overall objectives of the study are to investigate the improvement in hearing with the Ponto 4(s) on the implanted ear(s), in terms of the subject's ability to hear sounds and understand speech when using the device. The primary endpoint is to investigate the improvement in hearing with the Ponto 4(s) on the implanted ear for patients within intended use. These will be evaluated through a hearing and a speech test, both assessing the hearing with the Ponto 4(s) both on and off. Additionally, the subject will complete 2 patient reported outcome, report daily usage time of the device and assess satisfaction of connectivity devices. Minimal risks are expected for subjects participating in the study. Treatment is not provided in the study therefore risks are limited to the audiological measurements. The audiological measurements in the study are standard non-invasive measurements already familiar to the clinics. The measurements will require an extra effort and may be found slightly tiring by the subject. To mitigate the risk of tiredness the subject will be given the opportunity to have breaks during the visit. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04761926
Study type Interventional
Source Oticon Medical
Contact
Status Completed
Phase N/A
Start date January 15, 2021
Completion date February 24, 2021

See also
  Status Clinical Trial Phase
Completed NCT05086809 - Investigation of an Updated Bone-anchored Sound Processor N/A
Recruiting NCT05615649 - Expanded Indications in the Pediatric BONEBRIDGE Population N/A
Completed NCT04147611 - Remote Microphone (RM) - A Comparative Study N/A
Recruiting NCT06058767 - Preschool Hearing Screening N/A
Completed NCT03333577 - Evaluation of the Baha SoundArc in Pediatric Patients N/A
Completed NCT03766152 - Audiological Benefit and Improved Quality of Life With Two Bone Conduction Systems: ADHEAR vs. Bonebridge in Experienced Users N/A
Active, not recruiting NCT03742089 - Evaluation of the BHX Implant in Children With a BAHS
Not yet recruiting NCT06338670 - Clinical Performance of the Osia 3 Sound Processor Compared With the Osia 2 Sound Processor in Adult Osia Implant Users N/A
Completed NCT01822119 - Clinical Performance of a Transcutaneous Bone Conduction Hearing Solution (Baha® Attract System) N/A
Recruiting NCT04803279 - Investigating Hearing With Ponto 3 SuperPower, a Bone Anchored Hearing Aid - Investigating Hear
Not yet recruiting NCT04427631 - Exploring Interventions for Glue Ear During Covid-19 N/A
Completed NCT02022085 - Post-market Clinical Follow-up of a Magnetic Bone Conduction Implant (Cochlear Baha Attract System) N/A
Completed NCT01738490 - Long-term Stability and Survival Rates of a Novel Oticon Medical Bone Conduction Device Implant N/A
Recruiting NCT05055115 - Ph.D.-Project: Eustachian Tube Dysfunction: Causes, Diagnosis, Treatment, and Prognosis N/A
Completed NCT03129191 - Audiological Benefit With Non-implantable Bone Conduction Hearing Systems N/A
Recruiting NCT04899037 - Pilot Study to Evaluate the Long-term Chronic Care of Patients Who Could or do Utilize an Osseointegrated Device (OID)
Completed NCT01858246 - A Randomised Controlled Trial Comparing Bone Anchored Hearing Aid With Bonebridge N/A
Active, not recruiting NCT05166265 - Clinical Investigation Study of Safety and Performance of the Sentio System. N/A
Completed NCT01796236 - Clinical and Health Economic Evaluation With a New Baha® Abutment Combined With a Minimally Invasive Surgical Technique N/A
Completed NCT06256081 - Testing a New App for Children With Glue Ear N/A