Gonarthrosis Clinical Trial
Official title:
Does an Augmented Reality-based Navigation System in Total Knee Arthroplasty Allow a Better Alignment of the Lower Limb and Does it Improve Functional Results ? An Equivalence, Monocentric, Prospective and Randomized Study
The purpose of Total Knee Replacement (TKR) is to remove worn cartilage surfaces and replace them with artificial parts of the same shape. TKR can be used in cases of osteoarthritis, inflammatory rheumatism, bone necrosis of the knee or following malformative or traumatic sequelae. Implant alignment is paramount in TKR and the last years have seen a proliferation of alignment techniques following the introduction of computer and robotic-assisted surgery. Among Computer-assisted surgery, the augmented reality-based navigation system can be an option to improve accuracy in orthopaedic surgery. The hypothesis of this study is: the use of augmented reality-based navigation system allows a prosthesis alignment and positioning that is at least as good as with the traditional mechanically aligned technique, and therefore improves knee functional results. This study also aims at assessing the cost-effectiveness of this new technology.
In this randomised study, TKR will be performed either with the traditional mechanically aligned technique or with an augmented reality-based navigation system using Knee+ technology. Knee+ is a Class Im software medical device (European classification, Directive 93/42/EEC, Annex IX) and obtained CE Mark 0459 in May 2020. This technology is used in total knee replacement procedures, and offers the orthopedic surgeon intraoperative assistance in positioning the implants with the help of a pair of augmented reality glasses. The cutting planes are oriented with respect to the mechanical axes calculated according to anatomical landmarks acquired with a pointer. The connected glasses calculate precisely the 3D coordinates of the instruments thanks to the analysis of their specific markers (QR-Code), filmed by the integrated camera. The navigation information is displayed in the surgeon's field of vision, who interacts with the application thanks to the glasses' accelerometers. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT04460989 -
Assessment of Patient Satisfaction After Arthroplasty: A Comparative Study by Implant Type
|
||
Recruiting |
NCT02411097 -
Role of Femoral Nerve Block on Prevention of Postoperative Deep Venous Thromboembolism
|
N/A | |
Not yet recruiting |
NCT05435690 -
Evaluation of a New Navigation System in Computer-assisted Total Knee Arthroplasty
|
N/A | |
Completed |
NCT06308887 -
Comparison of Ultrasound-Guided Perimeniscal Steroid and 5% Dextrose Injections in Knee Osteoarthritis
|
Phase 4 | |
Recruiting |
NCT03951545 -
Clinical and Radiological Impact of Tibial Cutting Int Total Knee Arthroplasty, Accelerated Navigation Versus Extramedullary Targeting
|
N/A | |
Recruiting |
NCT06302075 -
Functional Recovery After Medial Monocompartmental Knee Prosthesis: One Day Protocol Versus Fast Protocol
|
N/A | |
Not yet recruiting |
NCT05877027 -
Exercise vs. Topical Diclofenac vs. PRP
|
N/A | |
Recruiting |
NCT04424628 -
Radiotherapy 3 vs 6 Gy in Gonarthrosis and Coxarthrosis
|
N/A | |
Completed |
NCT04577521 -
The Safety and Efficacy of Single IA-HA Injection in Patients With Knee Osteoarthritis: A Prospective Study
|
||
Recruiting |
NCT05814471 -
Validation orthèse Pour Gonarthrose
|
N/A | |
Completed |
NCT02638831 -
Ketorol Gel in Gonarthrosis and Low Back Pain
|
Phase 4 | |
Completed |
NCT01773226 -
Evaluation of Intra-articular Injection of Autologous Protein Solution ("APS(TM)") for the Treatment of Osteoarthritis (OA)
|
N/A | |
Completed |
NCT02977936 -
Management of Joint Pain Associated With Osteoarthritis of the Knee With Association of Plant Extracts.
|
||
Recruiting |
NCT05062109 -
Multimodal Geriatric Pre-authorization Before Scheduled Orthopedic Surgery
|
N/A | |
Not yet recruiting |
NCT06314191 -
Adipose Tissue and Symptomatic Gonarthrosis
|
N/A | |
Recruiting |
NCT02251535 -
In-vivo Comparison of Different Levels of Femoral Rollback in a Primary Total Knee Arthroplasty
|
N/A | |
Active, not recruiting |
NCT03734315 -
Routine Application of Ostenil® in Patients With Gonarthrosis
|
||
Completed |
NCT03389607 -
The Role of SCUBE-1 in Ischemia-reperfusion Injury
|
||
Completed |
NCT04225182 -
Evaluation of the Effectiveness of a Muscular Strengthening Protocol With an Instrumented Orthosis for Gonarthrosis Patients
|
N/A | |
Recruiting |
NCT04313894 -
WHARTON JELLY ORIGINATED MESENCHIAL STEM CELL in GONARTHROSIS
|
Phase 2 |