Glaucoma, Open-Angle Clinical Trial
Official title:
Choroidal Thickness and Its Correlations With Ocular Parameters in Cases With Primary Open-angle Glaucoma
Glaucoma is one of the leading causes of blindness worldwide that is a chronic public health problem. Unfortunately, glaucoma can be diagnosed when the disease reaches a certain level in today's conditions. The aim of this study was to investigate the diagnostic methods that can diagnose glaucoma before it reaches the advanced level and to identify pathophysiological processes. In this study, choroidal thickness was investigated in primary open-angle glaucoma cases and its correlations with OCT and multifocal ERG parameters were evaluated.
In this study, patients with primary open-angle glaucoma who have recently received a new diagnosis with healthy volunteers with age-matched groups were enrolled. All data from 49 glaucoma patients and 47 healthy volunteers were recorded and the study was completed. The study was carried out at the Afyon Kocatepe University Ophthalmology Department between January 2014 and April 2015. Routine ophthalmologic examinations of all participants were performed. Medical treatment was initiated on patients diagnosed with primary open-angle glaucoma. Intraocular pressures and visual acuities of all participants were recorded at baseline, at 1-month, at 3-month, and at 6-month. All participants underwent tests of multifocal electroretinography and the measurements of optic nerve head optical coherence tomography parameters and the choroidal thickness, at the same follow-ups. Visual acuities were measured by using the Snellen chart as the best corrected visual acuity. Intraocular pressures were measured by using applanation tonometry. Choroid thicknesses were also measured and recorded using EDI-OCT mode of optical coherence tomography device (Cirrus HD 4000, Carl Zeiss Meditec AG, Germany). Choroidal thicknesses were measured in three regions: fovea, 3mm nasal and temporal distances of the fovea. The mean of these three measurements was recorded as macular choroidal thickness. The same technician performed all multifocal electroretinography tests of the participants (Metrovision Monpack 3, Metrovision, France). Multifocal electroretinography tests were carried out from a distance of 33 cm using ERG-jet electrode, ground electrode, and a reference electrode. Electrical potential responses from 103 retina regions were recorded. Results were compared statistically and correlations were analyzed (SPSS 20.0, SPSS Inc. IL, USA). ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT05044793 -
A Clinical Study To Assess The Safety And Effectiveness Of The OMNI® Surgical System
|
||
Recruiting |
NCT06201455 -
Evaluation of Phacogoniotomy in Medically-controlled POAG
|
N/A | |
Recruiting |
NCT03369886 -
The Relationship Between Macular OCTA and GCIPL and Their Combinational Index Using AI
|
N/A | |
Active, not recruiting |
NCT04624698 -
iStent Inject New Enrollment Post-Approval Study
|
N/A | |
Recruiting |
NCT02679482 -
Following Patients After Selective and Pascal Laser Trabeculoplasty for Treatment of Chronic Open-Angle Glaucoma
|
N/A | |
Completed |
NCT02338362 -
Inhaled Corticosteroids: Effect on Intraocular Pressure in Patients With Controlled Glaucoma
|
Phase 4 | |
Active, not recruiting |
NCT01430923 -
Clinical Evaluation of Safety and Efficacy of Refrigeration Free Latanoprost
|
N/A | |
Completed |
NCT01489670 -
Observational Study of Lumigan® 0.01% Treatment for Patients With Primary Open Angle Glaucoma or Ocular Hypertension
|
N/A | |
Completed |
NCT00753168 -
Phase 1-2 Evaluation of OT-730 Eye Drops in Reducing the Intraocular Pressure in Patients With Ocular Hypertension or Open-Angle Glaucoma
|
Phase 1/Phase 2 | |
Completed |
NCT00693485 -
Safety and Effects of Brimonidine Intravitreal Implant in Patients With Glaucomatous Optic Neuropathy
|
Phase 2 | |
Completed |
NCT00051194 -
A 6-week Safety & Efficacy Study of Combination Intraocular Pressure-lowering Therapy in Patients With Open-angle Glaucoma or Ocular Hypertension
|
Phase 2 | |
Recruiting |
NCT04920227 -
Comparation of CLASS Combined With Phacoemulsification and CLASS Alone in the Treatment of Primary Open Angle Glaucoma
|
N/A | |
Active, not recruiting |
NCT03868124 -
Clinical Study Comparing Two Models of a Travoprost Intraocular Implant
|
Phase 3 | |
Completed |
NCT03267862 -
Scleral Response to Intraocular Pressure (IOP)
|
N/A | |
Recruiting |
NCT06066645 -
Travoprost Intraocular Implant + iStent Infinite vs. iStent Infinite Alone
|
Phase 3 | |
Recruiting |
NCT04912362 -
The Effectiveness of YAG Iridotomy in Preventing Peripheral Anterior Synechia After CLASS in Primary Open Angle Glaucoma
|
N/A | |
Completed |
NCT04949802 -
Glaucoma Surgery Using the ViaLase Laser System
|
N/A | |
Recruiting |
NCT04038034 -
Valuation of the Antioxidant and Neuroprotective Effects of CoQ10-MINIACTIVES® (COQUN® OS) in Patients Affected by Primary Open Angle Glaucoma
|
N/A | |
Completed |
NCT04632329 -
Negative Pressure Applied by the Equinox MPD for Severe Open Angle Glaucoma
|
N/A | |
Completed |
NCT01215786 -
Safety and Pharmacodynamics Study of AGN-207281 Ophthalmic Solutions Compared With Timolol Ophthalmic Solution or Placebo in Patients With Ocular Hypertension or Primary Open-Angle Glaucoma
|
Phase 1 |