Glaucoma Eye Clinical Trial
Official title:
Comparison Between Anterior Segment Optical Coherence Tomography and Ultrasound Bio Microscopy Parameters in Glaucoma Assessment
Study aiming to compare between anterior segment Optical Coherence Tomography and Ultrasound BioMicroscopy In Glaucoma aSSESMENT
Status | Not yet recruiting |
Enrollment | 50 |
Est. completion date | January 1, 2024 |
Est. primary completion date | December 1, 2023 |
Accepts healthy volunteers | |
Gender | All |
Age group | 18 Years to 75 Years |
Eligibility | Inclusion Criteria: - Patients with open and angle closure glaucoma. Male and female patients were included. Patient age: more than18 years old Exclusion Criteria: Previous glaucoma surgery. Previous cataract surgery. Media opacity. Associated ocular or intra ocular inflammation. Associated corneal pathology. |
Country | Name | City | State |
---|---|---|---|
n/a |
Lead Sponsor | Collaborator |
---|---|
Sohag University |
Barkana Y, Dorairaj SK, Gerber Y, Liebmann JM, Ritch R. Agreement between gonioscopy and ultrasound biomicroscopy in detecting iridotrabecular apposition. Arch Ophthalmol. 2007 Oct;125(10):1331-5. doi: 10.1001/archopht.125.10.1331. — View Citation
Casson RJ, Chidlow G, Wood JP, Crowston JG, Goldberg I. Definition of glaucoma: clinical and experimental concepts. Clin Exp Ophthalmol. 2012 May-Jun;40(4):341-9. doi: 10.1111/j.1442-9071.2012.02773.x. Epub 2012 Apr 5. — View Citation
Dada T, Mohan S, Sihota R, Gupta R, Gupta V, Pandey RM. Comparison of ultrasound biomicroscopic parameters after laser iridotomy in eyes with primary angle closure and primary angle closure glaucoma. Eye (Lond). 2007 Jul;21(7):956-61. doi: 10.1038/sj.eye.6702360. Epub 2006 May 5. — View Citation
Reinstein DZ, Gobbe M, Archer TJ. Anterior segment biometry: a study and review of resolution and repeatability data. J Refract Surg. 2012 Jul;28(7):509-20. doi: 10.3928/1081597X-20120620-02. — View Citation
Sharma R, Sharma A, Arora T, Sharma S, Sobti A, Jha B, Chaturvedi N, Dada T. Application of anterior segment optical coherence tomography in glaucoma. Surv Ophthalmol. 2014 May-Jun;59(3):311-27. doi: 10.1016/j.survophthal.2013.06.005. Epub 2013 Oct 15. — View Citation
Wirbelauer C, Scholz C, Haberle H, Laqua H, Pham DT. Corneal optical coherence tomography before and after phototherapeutic keratectomy for recurrent epithelial erosions(2). J Cataract Refract Surg. 2002 Sep;28(9):1629-35. doi: 10.1016/s0886-3350(02)01366-4. — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | comparison between Anterior Segment Optical Coherence Tomography And ltrasound Biomicroscopy Parameters In Glaucoma Assesment | . UBM provides biometric information of anterior segment structures, such as anterior chamber (AC) depth, anterior chamber angle (ACA), and iris thickness. UBM provides more detailed information compared to slit-lamp, gonioscopy or B-scan examinations for diagnosis and follow-up of PAC eyes. It can be used to study the causes of secondary glaucoma. Precise quantitative evaluation of the anterior chamber angle structures can help in diagnosis and management of various pathologies related to glaucoma .
anterior segment-optical coherence tomography (AS-OCT) has developed rapidly. With a higher imaging resolution than UBM, AS-OCT makes it easier for the operator and software to identify ACA structures. such as: the scleral spur (SS), iris surface, Schwalbe's line, even trabecular meshwork , and Schlemm's canal. This provides more precise analysis of the angle opening distance from the SS, ACA, trabecular iris angle , and trabecular iris space area |
1 year |
Status | Clinical Trial | Phase | |
---|---|---|---|
Enrolling by invitation |
NCT05566626 -
Retinal Oxygenation Estimation Trial With Mantis Photonics Hyperspectral Camera
|
N/A | |
Recruiting |
NCT05685485 -
Tied Tube Trial in Glaucoma Surgery
|
||
Not yet recruiting |
NCT03682783 -
Artificial Intelligence-assisted Glaucoma Screening (AIAGS)
|
||
Recruiting |
NCT04602923 -
Keratometric Change After XEN, Trabeculectomy and Tube Shunts
|
N/A | |
Recruiting |
NCT04671550 -
The Value of Visual Field Examination in Driving Licence.
|
||
Completed |
NCT03624361 -
MINIject Glaucoma Implant in European Patients
|
N/A | |
Withdrawn |
NCT04676126 -
Augmented Macular Pigment-containing Nutraceutical and Central Visual Function
|
Phase 4 | |
Not yet recruiting |
NCT05593354 -
MicroPulse TLT - UK Study
|
||
Completed |
NCT03187418 -
Treatment Outcomes of MicroPulse Trans-scleral Cyclophotocoagulation in Uncontrolled Glaucoma
|
N/A | |
Completed |
NCT03996200 -
MINIject in Patients With Open Angle Glaucoma Using Single Operator Delivery Tool
|
N/A | |
Completed |
NCT03338101 -
Comparative Study Between Tonometers
|
N/A | |
Completed |
NCT04052165 -
IOP Reduction and Complications of Polymethyl Methacrylate GDD on Glaucoma Patient
|
N/A | |
Completed |
NCT04648943 -
The Effect of Trabeculectomy & Ex-PRESS Glaucoma Drainage Implant on the Corneal Biomechanical Properties
|
N/A | |
Completed |
NCT03138928 -
An Innovation in Glaucoma Surgery: XEN45 Gel Stent Implantation
|
N/A | |
Completed |
NCT05895617 -
Assessment of the Occuity PM1 Pachymeter
|
||
Enrolling by invitation |
NCT04381611 -
INTEGRAL Study: A Longitudinal Study of Surgeries and Lasers in Glaucoma: Long-term Results and Success Predictors Analysed From a Large-scale Retrospective and Prospective Glaucoma Register
|
||
Completed |
NCT05449041 -
Bulbicam Validation on Glaucoma- and Cataract Patients
|
||
Completed |
NCT03797846 -
Comparison of Fixation Suture Type in Glaucoma Surgery
|
N/A | |
Terminated |
NCT04037917 -
First-In-Man Study for an Ophthalmic Synthetic Tissue Substitute
|
N/A | |
Completed |
NCT05147610 -
Precision of the Icare200 for Measuring Intraocular Pressure
|
N/A |