Fluid Responsiveness Clinical Trial
Official title:
Evaluation of Pulse-oximetry Derived Perfusion Index Change Post Passive Leg Raising for Fluid Responsiveness in Critically Ill Patients
Peripheral Perfusion Index (PI) has been investigated for its use in hemodynamic monitoring. The PI is derived from the photoelectric plethysmographic signal of the pulse oximeter. The changes in the PI reflect changes in peripheral vasomotor tone. In critically ill patients, the same value was found to represent a very sensitive cutoff point for determining abnormal peripheral perfusion, as defined by a prolonged Capillary Refill Time (CRT). However, age, gender, and ambient temperature have all been shown to affect the measure of CRT in normal volunteers, and the presence of a CRT > 2 or 3 seconds was not predictive of blood loss in phlebotomized volunteers. In addition, the CRT has been shown to have poor intra-observer agreement when a cutoff a two seconds was used in adult emergency room patients.13 Therefore, PI can be used for monitoring peripheral perfusion in critically ill patients.14PI shows the perfusion status of the tissue in the applied area for an instant and a certain time interval. The PI value ranges from 0.02% (very weak) to 20% (strong). As non-invasive CO monitors (ICON ®) is not available in many centers in our country due to its high cost, we try to validate other simple non-invasive method to be used to assess FR in critically ill patients. The purpose of this study is to investigate the efficacy of pulse-oximeter derived PI measurement in assessment of fluid responsiveness in critically ill patients in comparison with CO response.
After approval by NHTMRI-IRB Ethical Committee.All demographic data will be obtained including the patients age, sex,associated co-morbidities (diabetes mellitus & hypertension). Continuous blood pressure, continuous electrocardiogram, heart rate (HR), and SpO2 (measured by pulse oximetry). Patients who are eligible and have signs of hemodynamic instability, PLR will be performed by adjusting the bed and not by manually raising the patient's legs. Bronchial secretions must be carefully aspirated before PLR. If awake, the patient should be informed of what the test involves.PLR should start from the semi-recumbent and not the supine position. Adding trunk lowering tosupine position and leg raisingfor 45° for 60 seconds, this mobilizes venous blood from the large splanchnic compartment, thus magnifying the increasing effects of leg elevation on cardiac preload.18COand PI measurements will be recorded in the same patients. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT01941472 -
Transcutaneous pO2, Transcutaneous pCO2 and Central Venous pO2 Variations to Predict Fluid Responsiveness
|
N/A | |
Terminated |
NCT03208023 -
RESIPI for Reducing Perioperative Major Adverse Cardiac Events
|
N/A | |
Completed |
NCT03713008 -
Assessment Of Carotid Flow During General Anesthesia
|
N/A | |
Completed |
NCT02277353 -
Evaluation of SVV From NICOM as a Predictor of Fluid Responsiveness in Prone Position During Spine Surgery
|
N/A | |
Not yet recruiting |
NCT04092036 -
Optic Nerve Sheath Diameter in Prediction of Fluid Responsiveness
|
||
Completed |
NCT04060069 -
Pneumoperitoneum and Trendelenburg Position on Fluid Responsiveness
|
||
Recruiting |
NCT05153837 -
Effect of Oral Water in Healthy Volunteers on Cardiac Output, Regional Flow and Microcirculation in Healthy Volunteers
|
N/A | |
Not yet recruiting |
NCT06143111 -
A Comparison of Thoracic Electrical Bioimpedance and FloTrac/Vigileo
|
N/A | |
Not yet recruiting |
NCT05601622 -
RPVI for Fluid Responsiveness in Children
|
N/A | |
Completed |
NCT04889807 -
Study of End Tidal Carbon Dioxide (EtCO2) Variation After an End- Expiratory Occlusion Test as a Predictive Criteria of Fluid Responsiveness in Mechanically Ventilated Patients
|
||
Recruiting |
NCT04186416 -
Effectiveness of the Pressure Recording Analytical Method in Predicting Fluid Responsiveness in Pediatric Critical Care Patients
|
||
Completed |
NCT01996956 -
Prediction of Fluid Responsiveness by NICOM (Non-invasive Cardiac Output Monitoring) in Children With Congenital Heart Disease After Cardiac Surgery
|
N/A | |
Enrolling by invitation |
NCT04388995 -
SVV and PPV Predict Fluid Responsiveness in Mechanically Ventilated Elderly Patients Under General Anesthesia
|
N/A | |
Not yet recruiting |
NCT04574011 -
Fluid Responsiveness in Spontaneously Ventilating Patient
|
N/A | |
Completed |
NCT01821742 -
Echocardiography in Kids Intensive Care Decision Support
|
||
Completed |
NCT04802668 -
Factors Influencing of Pulse Pressure Variation (PPV)
|
||
Not yet recruiting |
NCT06254456 -
Fluid Responsiveness in Prone Patients
|
N/A | |
Completed |
NCT02789124 -
Diagnostic Value of Passive Leg Raise Induced Changes in Carotid Artery Flow Time to Predict Fluid Responsiveness in Critically Ill Patients
|
N/A | |
Completed |
NCT02040948 -
Accuracy of Pulse Pressure Variation and of Pleth Variability Index to Predict the Response to a Fluid Challenge
|
N/A | |
Withdrawn |
NCT01898975 -
A Gray Zone Approach to Stroke Volume Variation Derived From NICOM
|
N/A |