Hemorrhage Clinical Trial
Official title:
Effectiveness of the Pressure Recording Analytical Method in Predicting the Fluid Responsiveness in Pediatric Surgical Critical Care Patients
The Pressure Recording Analytical Method, invasive hemodynamic monitoring, is an uncalibrated pulse contour analysis, installed in the Mostcare® system that allows a continuous estimation of the stroke volume and thus the cardiac output, by the relationship between the area under the curve of the systolic portion of the arterial blood pressure curve and the dynamic impedance of the cardiovascular system. The objectives of the study are to determine if the parameters measured by Mostcare® make it possible to predict the response to volume expansion in pediatric surgical critical care patients, sedated, intubated and ventilated, by comparing the changes in stroke volume, induced by a volume expansion, measured by trans-thoracic echocardiography.
Children undergoing major surgery or severe trauma with bleeding require regular hemodynamic evaluation, including cardiac output measurement, to maintain adequate organ perfusion. In fact, administration of fluid to improve cardiac output is the mainstay of hemodynamic resuscitation. However, not all patients respond to fluid therapy, and excessive fluid administration is harmful. Therefore, the vascular filling strategy requires a thorough hemodynamic evaluation. Many predictive tools for fluid responsiveness have been validated in adults, and are based on heart-lung interaction in ventilated patients. Up to now, respiratory variation in aortic blood flow peak velocity, measured by transthoracic or transoesophageal cardiac echocardiography, is the only variable shown to effectively predict fluid responsiveness in children. However, the use of these methods does not allow continuous monitoring (trans-thoracic echocardiography) or is not easily achievable in current practice (trans-esophageal echocardiography). In addition, these monitoring tools require learning and inter- and intra-individual variability is not negligible, ranging from 1% to 20%. The Pressure Recording Analytical Method, invasive hemodynamic monitoring, is an uncalibrated pulse contour analysis, installed in the Mostcare® system, that allows a continuous estimation of the stroke volume and thus of the cardiac output, by the relationship between the area under the curve of the systolic portion of the arterial blood pressure curve and the dynamic impedance of the cardiovascular system. The goal of this study is to assess the ability of dynamic cardiovascular variables measured using Mostcare® to predict fluid responsiveness in pediatric surgical critical care patients, sedated, intubated and ventilated, in prone position, by comparing the changes in stroke volume (SV), induced by a volume expansion (VE), measured by trans-thoracic echocardiography. For the purpose of the study, responders (Rs) to VE are patients showing an increase in SV measured using transthoracic echocardiography of at least 15% after VE. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT02815670 -
Reversal Dabigatran Anticoagulant Effect With Idarucizumab
|
Phase 3 | |
Completed |
NCT04588350 -
Clinical Investigation Evaluating a New Autotransfusion Device in Cardiac Surgery
|
N/A | |
Recruiting |
NCT02972385 -
Pharmacogenomics of Warfarin in Hispanics and Latinos
|
||
Completed |
NCT02554006 -
Predischarge Bundle to Minimize Negative Impact on Quality of Life of Nuisance Bleedings
|
N/A | |
Completed |
NCT02569606 -
Transfusion and Coagulation Management in Trauma Patients After the Introduction of a Coagulation Algorithm
|
||
Recruiting |
NCT02446730 -
Efficacy and Safety of BiomatrixTM Stent and 5mg-Maintenance Dose of Prasugrel in Patients With Acute Coronary Syndrome
|
Phase 4 | |
Completed |
NCT01935427 -
Comparison of Compensatory Reserve Index to Intravascular Volume Change and Stroke Volume
|
N/A | |
Completed |
NCT01955720 -
Safety, Tolerability, PK and PD of BI 655075 and Establishment of BI 655075 Dose(s) Effective to Reverse Prolongation of Blood Coagulation Time by Dabigatran
|
Phase 1 | |
Recruiting |
NCT01709786 -
Non-Invasive Hemoglobin Monitoring in Patients With Hemorrhage
|
N/A | |
Completed |
NCT01210417 -
Trauma Heart to Arm Time
|
N/A | |
Completed |
NCT01191554 -
Dose-ranging Study of Tranexamic Acid in Valve Surgery
|
N/A | |
Completed |
NCT01136590 -
Multicenter, Randomized Placebo-controlled Clinical Trial to Evaluate the Effect of Perioperative Use of Tranexamic Acid on Transfusion Requirements and Surgical Bleeding in Major Spine Surgery
|
Phase 4 | |
Completed |
NCT01085006 -
The Effect of Tranexamic Acid on Postpartum Hemorrhage During and After Cesarean Delivery
|
Phase 1/Phase 2 | |
Completed |
NCT00700141 -
Non-Interventional Study About Treatment of Hemorrhages in Thyroid Surgery With TachoSil®
|
N/A | |
Completed |
NCT00375466 -
Tranexamic Acid, Hemorrhage and Transfusions After Combined Aortic Valve Replacement and Coronary Artery Bypass Surgery.
|
N/A | |
Completed |
NCT00479362 -
Anticoagulant Therapy During Pacemaker Implantation
|
Phase 4 | |
Completed |
NCT00147420 -
RCT of Zhi Byed 11 (ZB11) Versus Misoprostol in Tibet
|
N/A | |
Recruiting |
NCT05945680 -
Tranexamic Acid in Breast Esthetic Surgery.
|
Phase 4 | |
Completed |
NCT03273322 -
Assessment of Dual Antiplatelet Therapy Versus Rivaroxaban In Atrial Fibrillation Patients Treated With Left Atrial Appendage Closure
|
Phase 2/Phase 3 | |
Withdrawn |
NCT05672407 -
The Role of Local Tranexamic Acid on Periorbital Oculoplastic Surgery
|
Phase 4 |