Fluid Responsiveness Clinical Trial
Official title:
Evaluation of Stroke Volume Variation Derived From NICOM as a Predictor of Fluid Responsiveness in Neurosurgical Patients: A Gray Zone Approach
Optimal fluid management has been considered as crucial part to determine postoperative outcome and organ function. Recently developed, non invasive cardiac output measurement(NICOM, Cheetah Medical, Portland, OR)has enabled continuous cardiac output(CO) monitoring just by attaching electrode on chest wall. Moreover, CO and SSV derived from NICOM have been demonstrated as predictors of fluid responsiveness. Therefore, the aim of this study is to evaluate stroke volume variation derived from NICOM as a predictor of fluid responsiveness in neurosurgical patients. In addition, we plan to reveal inconclusive patients using gray zone approach.
Optimal fluid management has been considered as crucial part to determine postoperative outcome and organ function. Many reports have focussed on evaluation of fluid responsiveness using various parameters such as pulse pressure variation (PPV) or stroke volume variation (SSV) derived from invasive or semi-invasive monitoring. Recently developed, non invasive cardiac output measurement(NICOM, Cheetah Medical, Portland, OR)has enabled continuous cardiac output(CO) monitoring just by attaching electrode on thorax. Moreover, CO and SSV derived from NICOM have been demonstrated as predictors of fluid responsiveness. Therefore, the aim of this study is to evaluate stroke volume variation derived from NICOM as a predictor of fluid responsiveness in neurosurgical patients. In addition, we plan to reveal inconclusive patients using gray zone approach. ;
Observational Model: Case-Only, Time Perspective: Prospective
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT01941472 -
Transcutaneous pO2, Transcutaneous pCO2 and Central Venous pO2 Variations to Predict Fluid Responsiveness
|
N/A | |
Terminated |
NCT03208023 -
RESIPI for Reducing Perioperative Major Adverse Cardiac Events
|
N/A | |
Completed |
NCT03713008 -
Assessment Of Carotid Flow During General Anesthesia
|
N/A | |
Completed |
NCT02277353 -
Evaluation of SVV From NICOM as a Predictor of Fluid Responsiveness in Prone Position During Spine Surgery
|
N/A | |
Not yet recruiting |
NCT04092036 -
Optic Nerve Sheath Diameter in Prediction of Fluid Responsiveness
|
||
Completed |
NCT04060069 -
Pneumoperitoneum and Trendelenburg Position on Fluid Responsiveness
|
||
Recruiting |
NCT05153837 -
Effect of Oral Water in Healthy Volunteers on Cardiac Output, Regional Flow and Microcirculation in Healthy Volunteers
|
N/A | |
Not yet recruiting |
NCT06143111 -
A Comparison of Thoracic Electrical Bioimpedance and FloTrac/Vigileo
|
N/A | |
Not yet recruiting |
NCT05601622 -
RPVI for Fluid Responsiveness in Children
|
N/A | |
Completed |
NCT04889807 -
Study of End Tidal Carbon Dioxide (EtCO2) Variation After an End- Expiratory Occlusion Test as a Predictive Criteria of Fluid Responsiveness in Mechanically Ventilated Patients
|
||
Recruiting |
NCT04186416 -
Effectiveness of the Pressure Recording Analytical Method in Predicting Fluid Responsiveness in Pediatric Critical Care Patients
|
||
Completed |
NCT01996956 -
Prediction of Fluid Responsiveness by NICOM (Non-invasive Cardiac Output Monitoring) in Children With Congenital Heart Disease After Cardiac Surgery
|
N/A | |
Enrolling by invitation |
NCT04388995 -
SVV and PPV Predict Fluid Responsiveness in Mechanically Ventilated Elderly Patients Under General Anesthesia
|
N/A | |
Not yet recruiting |
NCT04574011 -
Fluid Responsiveness in Spontaneously Ventilating Patient
|
N/A | |
Completed |
NCT01821742 -
Echocardiography in Kids Intensive Care Decision Support
|
||
Completed |
NCT04802668 -
Factors Influencing of Pulse Pressure Variation (PPV)
|
||
Not yet recruiting |
NCT06254456 -
Fluid Responsiveness in Prone Patients
|
N/A | |
Completed |
NCT02789124 -
Diagnostic Value of Passive Leg Raise Induced Changes in Carotid Artery Flow Time to Predict Fluid Responsiveness in Critically Ill Patients
|
N/A | |
Completed |
NCT02040948 -
Accuracy of Pulse Pressure Variation and of Pleth Variability Index to Predict the Response to a Fluid Challenge
|
N/A | |
Completed |
NCT05419570 -
Short Time Low PEEP Challenge and Mini Fluid Challenge
|