Clinical Trials Logo

Clinical Trial Summary

This study is designed as a multicenter prospective data recording study to document the performance of the DAT clip as part of standard medical care of patients. No experimental interventions will be performed.


Clinical Trial Description

Endoscopic clipping devices are instruments designed to achieve tissue approximation during gastrointestinal endoscopy. Although endoscopic clips were initially developed for the primary purposes of accomplishing hemostasis of focal gastrointestinal bleeding, the indications for endoscopic clipping have expanded to include closure of perforations and fistulas, securing positioning of catheters and stents as well as to provide a radio-opaque markers to direct endoscopic, radiological, and surgical therapy. Traditionally, through-the-scope (TTS) clipping devices consist of 2 main components: metallic double pronged clips and delivery/deployment catheter-handle assembly. TTS clips are the most used devices for both hemostasis and defect closure given the familiarity and ease of use. However, larger defects or those in a difficult position within the GI tract can be difficult to close using conventional TTS clips alone, given the inherent restrictions in clip opening width and inability to approximate large gaps firmly and securely. Incomplete closure can have serious consequences, including delayed bleeding and need for additional interventions including surgery for treatment of acute perforations. The Dual Action Tissue (DAT) clip is a novel, Federal Drug and Administration (FDA) approved commercially available 3-arm TTS clip designed for endoscopic closure of large defects. Compared to conventional TTS clips, the DAT clip has an additional center post or fixed column in the middle position. The two arms of the DAT clip operate independent of each other, with an overall maximum opening width angle of 60 degrees. Opening and closing of each arm is controlled by two color-coded handles, which facilitates distinguishment of the clip arms during operation. The arm on one side of the DAT clip is opened to clamp the edge of a defect. The clamped mucosa can then be pulled close to the other side of the defect. The second arm of the DAT is then opened to clamp the opposite edge. Once both edges of the defect are secured by the arms of the DAT clip, the clip can then be deployed by firmly pressing and releasing both handles simultaneously. Experimental studies using the DAT clip have confirmed its safety and efficacy and shown it to be easy to operate, safe and effective for defect closure. Our initial experience in 6 cases (unpublished data) supports its safety and its utility as an additional endoscopic tool in our armamentarium for challenging tissue approximation. However, more data is needed to evaluate the performance and the role of the DAT clip. The purpose of this study is to prospectively evaluate our experience with the DAT clip as part of routine medical care. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05852457
Study type Observational
Source AdventHealth
Contact Dennis Yang, MD
Phone 407-303-2570
Email Dennis.Yang.MD@adventhealth.com
Status Recruiting
Phase
Start date August 31, 2022
Completion date February 2026

See also
  Status Clinical Trial Phase
Completed NCT02685878 - Outcomes of Women After Obstetric Fistula Repair
Completed NCT02962141 - A Study of Hemodialysis Arteriovenous Fistulae Stenosis Treated With APERTO N/A
Completed NCT02770352 - Fistula Formation and Successful Repair
Recruiting NCT01388257 - Anal Crohn Fistula Surgery N/A
Completed NCT00544492 - Study of Pain, Anxiety and Complications Related to Cannulation of Arteriovenous (AV) Fistula in Chronic Hemodialysis Patients Phase 4
Recruiting NCT05616104 - FLEX FIRST Registry Research Protocol
Completed NCT00500968 - Study Assessing the Effect of Transpapillary Pancreas Duct Stent in Resection of the Pancreatic Tail N/A
Completed NCT05602987 - Comparison Study of the Effect of Enema in Anal Surgery N/A
Recruiting NCT04543539 - IN.PACTâ„¢ AV Access Post-Approval Study (PAS002)
Terminated NCT01321866 - Cutting Balloon Versus Non-cutting Balloon for the Treatment of Venous Stenosis in the Fistulas of Hemodialyzed Patients N/A
Recruiting NCT05766566 - Treatment of Perianal Fistulas in Crohn's Disease With Autologous Microfragmented Adipose Tissue With the Lipogems System
Withdrawn NCT03685955 - Efficacy of Amniotic Membranes in Complex Genitourinary Reconstruction
Completed NCT02374762 - Hemodialysis Vascular Access Imaging Study N/A
Not yet recruiting NCT04774588 - HoloStream Study - Video Capture Device Usage N/A
Completed NCT03120689 - VITOM Study: A Randomized, Controlled Trial. N/A
Completed NCT01144962 - Dose-escalating Therapeutic Study of Allogeneic Bone Marrow Derived Mesenchymal Stem Cells for the Treatment of Fistulas in Patients With Refractory Perianal Crohn's Disease Phase 1/Phase 2
Not yet recruiting NCT00653094 - An Open Label, Prospective, One Arm, Feasibility, Study for The Use of Halevy Kit for the Treatment of Perianal Fistulas in Patients With Crohn's Disease N/A
Active, not recruiting NCT05418816 - SelfWrap-Assisted Arteriovenous Fistulas N/A
Withdrawn NCT04073472 - Mesenchymal Stem Cells for the Treatment of Pouch Fistulas in Crohn's Phase 1
Completed NCT02686957 - Recurrence and Pregnancy Post-repair of Obstetric Fistula in Guinea N/A