Clinical Trials Logo

Fine Needle Aspiration clinical trials

View clinical trials related to Fine Needle Aspiration.

Filter by:
  • Completed  
  • Page 1

NCT ID: NCT04834193 Completed - Clinical trials for Endoscopic Ultrasound

Wet-suction Versus Slow-pull for EUS-FNB of Solid Lesions

WEST-FNB
Start date: March 29, 2021
Phase: N/A
Study type: Interventional

A randomized cross-over study investigating the impact of two different suction techniques on histological yield and sample quality of specimens collected by endoscopic ultrasound biopsy from solid lesions using histology needles.

NCT ID: NCT01479803 Completed - Pancreatic Tumor Clinical Trials

Comparison of Two Needles (ProCore vs EchoTip) for the Diagnosis of Pancreatic Solid Mass Under EUS

PICORE
Start date: October 2011
Phase: Phase 3
Study type: Interventional

The negative predictive value of fine needle aspiration under ultrasound endoscopy (EUS) for the diagnostic of solid pancreatic masses is 70% on average in the current literature with 22 gauge needles. There is a wide variability of this rate across studies (from 38 to 92%). In case of negativity of the biopsy, the risk of missing a pancreatic cancer whose prognosis is severe and extensive treatment, remains important. To improve the sensitivity of EUS echo endoscopy, several methods were used. A new needle (Echo Tip ® HD ProCore ™) has received CE Mark in the field of EUS. This instrument combines the comfortable and handy size of 22 Gauge and innovative design (window lateralized bevel) with in vitro studies obtaining core biopsy. In addition, a single pass through the tumor is achieved with this hand against several (2-3 minimum) with the current hardware. The theoretical goal is to have a tissue material more abundant during the sampling, without increasing morbidity and increase the diagnostic accuracy. A preliminary prospective study with this material has shown interesting results (increase the diagnostic accuracy of 15%). To determine the diagnostic gain with this new hand, it seemed essential to propose a prospective comparative study (22 gauge needle ProCore ™ versus the old EchoTip ® 22-Gauge) randomized (randomization of the order of the needles) in crossover (on the same lesion) in samples of pancreatic solid tumors. The caliber of 22 gauge is the gauge most often used for punctures under ultrasound endoscopy, resulting in less morbidity. Puncture by the 2 needles on the same injury can limit the effect of variability between patients and thereby have a better power for the investigators study without increasing the risk of complications (the needle ProCore ™ does not require that one pass through the tumor). The study of pancreatic solid tumors is one that poses the biggest diagnostic problem still present in the investigators daily practice. The aim of this study is to compare the diagnostic accuracy of the needle ProCore™ versus EchoTip® in etiological cyto histological diagnostic for pancreatic solid tumors under EUS.