Clinical Trials Logo

Clinical Trial Summary

Fetal cardiac monitoring is used during labor. Fetal decelerations may imply fetal hypoxia and distress. Brain activity monitoring is not used to evaluate fetal distress during labor. In this study the investigators intend to use an EEG based algorithm to evaluate and monitor fetal brain activity during the 2nd stage of labor.


Clinical Trial Description

Fetal heart rate (FHR) monitoring is commonly used in order to reduce fetal intrapartum asphyxia or any associated long-term disabilities. The electronic fetal monitoring (EFM) was first described by Hon and others during the 1960s (1) (2) and introduced into clinical practice before any clear evidence of benefits had been demonstrated. The EFM records the fetal heart rate, and characteristics such as baseline, accelerations, decelerations and variability are constantly evaluated in order to assess the hypoxic condition of the fetus and to identify fetal distress. Nevertheless, most of the studies (3-5) demonstrated that abnormal patterns of the fetal heart rate are of low predictive value for intrapartum fetal hypoxia or metabolic acidosis. Among high-risk pregnant woman, the probability of fetal metabolic acidosis in the presence of repeated, variable decelerations is 25%, and 48% in the presence of late decelerations (6). According to the Cochrane review (7) EFM didn't decrease the rates of cerebral palsy (CP), asphyxias complications or perinatal morbidity. The positive predictive value of non-reassuring FHR patterns for the prediction of CP among singleton newborns with birth weight of 2500 grams or more is only 0.14% (8). Hypoperfusion to a certain brain areas involves the rapid loss of brain function due to disturbances in brain blood supply. EEG shows typical changes in brain ischemia. These changes include: attenuation of faster waves, particularly in the beta and alpha frequency bands; enhancement of slower waves, mainly in the delta frequency band; regional attenuation without delta enhancement (RAWOD) and reduction of variability in the EEG signal (9). However, reaching effective sensitivity and specificity in immediate brain ischemia detection on the basis of EEG changes is still considered a challenge, as it depends on the presence of a skilled expert in neurophysiology to analyses raw EEG data in real-time. The investigators developed a unique platform algorithm, which analyses EEG data, and recognizes patients suffering from brain ischemia (stroke), based on the phenomena of interhemispheric decreased synchronization. Interhemispheric synchronization is the measure of correlation in EEG activity between ipsilateral and contralateral hemispheres, where values range between 1 (complete synchronization) and 0 (no synchronization). Increased synchronization means greater correlation between related ipsilateral and contralateral activities and vice versa for decreased synchronization. Normal brains should have a high correlation/ synchronization. Once brain ischemia occurs and the hemisphere is damaged, the interhemispheric synchronization decreases. In a recent study, we have shown the decrease in synchronization when a certain part of the brain is anaesthetized, causing a lesion similar to brain ischemia, and the recovery of synchronization, when the anesthesia recovered2. In another study, the investigators have tested the reliability of the algorithm in patients undergoing mechanical thrombectomy for acute stroke. In the study patients with acute stroke admitted to neuro angio intervention undergone short EEG test for 5 minutes. At the end of the procedure patients underwent a second short EEG test. In the test the interhemispheric synchronization were analyzed. It was shown that patients admitted to the neuro-angio intervention, who had brain tissue that might be salvable, had an average synchronization of 0.8. If the procedure succeeded and there was a clinical improvement - the synchronization remained high. If the procedure did not succeed, or succeed without clinical improvement, the synchronization decreased to an average of 0.65. Importantly, patients who were not candidates for neuro intervention, because they didn't have salvable brain, their index of synchronization was low to begin with (figure 1a and 1b). This preliminary assay proves the ability of the synchronization index to detect brain hypoperfusion that occurs, for example, in stroke. The objective of this proof of concept study is to test whether there is a correlation between the EEG index of interhemispheric synchronization, to the umbilical PH of the newborn and to the gold standard fetal heart rate monitor. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03930277
Study type Observational
Source Rambam Health Care Campus
Contact Roy Lauterbach, MD
Phone 972-52-9432416
Email r_lauterbach@rambam.health.gov.il
Status Not yet recruiting
Phase
Start date December 31, 2022
Completion date March 1, 2024

See also
  Status Clinical Trial Phase
Completed NCT02379728 - Ghana PrenaBelt Trial: A Positional Therapy Device to Reduce Still-Birth N/A
Active, not recruiting NCT00189007 - Antenatal Allopurinol During Fetal Hypoxia Phase 3
Recruiting NCT05681624 - Maternal Oxygen Supplementation for Intrauterine Resuscitation N/A
Completed NCT03108040 - Evaluation of Fetal Cardiac Function and Vascular Hemodynamics in Intrauterine Growth Restriction
Completed NCT02377817 - Halifax PrenaBelt Trial N/A
Active, not recruiting NCT02643108 - Lateral Episiotomy or Not in Vacuum Assisted Delivery in Non-parous Women N/A
Completed NCT02741284 - Oxygen for Intrauterine Resuscitation of Category II Fetal Heart Tracings N/A
Terminated NCT05147584 - Trans-abdominal Fetal Pulse Oximetry N/A
Recruiting NCT01533701 - Scalp Sampling for Fetal Surveillance N/A
Terminated NCT04437407 - UniSA BackOff! Study: Adelaide PrenaBelt Trial N/A
Completed NCT03146507 - Assessment of Cardiac Sparing in Fetal Hypoxia N/A
Recruiting NCT04876846 - Trans-abdominal Fetal Pulse Oximetry; Tissue Light Scattering and Signal Integrity N/A
Recruiting NCT06405984 - Trans-Abdominal Fetal Pulse Oximetry - EFS-IDE Early Phase 1
Suspended NCT04364308 - The Relationship Between Umbilical Cord ph and Feto-maternal Doppler Studies in Scheduled Nonlaboring Term Singleton Caesarean Deliveries