View clinical trials related to Fallopian Tube Injury.
Filter by:Two Millimetres needlescopic instruments induce minimal damage to the abdominal wall and have excellent cosmetic results. However, these instruments are fragile and expensive with short weak jaws. The aim of this study is to present a novel needlescopic approach using 1.6-mm Suture Grasper Device [SGD], modified polypectomy snare and a home-made Snare (HMS) for the treatment of congenital inguinal hernias [CIH] in girls. Over a period of one year from March 2018 to March 2019 a prospective study was conducted in three tertiary centres on 53 girls presented with CIH. Preoperative inguinoscrotal U/S was done for all patients to confirm the diagnosis and to measure the diameter of internal inguinal ring [IIR]. All patients were repaired using needlescopic inversion and snaring of the hernia sac using 2-SGDs and a snare. Follow up period ranged from 12 to 24 (Median 16.5) months. Fifty-three girls with 74 hernias were included in this study. Their mean age was 37.8 months. Internal inguinal ring diameter (IIR) ranged between 8-15 mm with a mean of 11.8±2.8mm. Mean operative time was 15.5 minutes in bilateral and 11.4 minutes in unilateral cases. Mean operative time for inversion, snaring, and sac extraction was 4.2±1.3 minutes. All cases were completed successfully without conversion and without complications. Follow up period ranged from 12 to 24 (Median 16.5) months with non-visible scar and no recurrence among the studied patients. Needlescopic inversion and snaring of inguinal hernia using 1.6mm instruments is a safe, rapid and feasible method for CIH repair in girls with invisible scar and no short-term recurrence.