End Stage Renal Disease (ESRD) Clinical Trial
Official title:
A Clinical Study Comparing the Basic Performance and Blood Compatibility Characteristics of Nipro ELISIO-H, Gambro Polyflux Revaclear and Fresenius Optiflux Dialyzers
The aim of the study is to confirm the safety and clinical effectiveness of Nipro ELISIO-15H and to compare its performance characteristics and hemocompatibility with those of the commercially available dialyzers in U.S.A., Gambro Polyflux Revaclear and Fresenius F160NRe. 10 stable patients will be dialyzed 3 times/week with each dialyzer over 3 weeks. Blood samples for several parameters will be collected during hemodialysis to assess the performance and hemocompatibility of the dialyzers under study. Data thus collected will be analyzed for comparison by standard statistical analysis.
Current patients receiving dialysis treatment for end stage renal disease and who meet the inclusion/exclusion criteria will be entered into the study. These patients will continue on their standard dialysis regimen as stated in the clinics Standard Operating Procedures. Each patient will be studied for three weeks with each week starting with a dialyzer of a different manufacture but of comparable characteristics. Solute clearances and removal will be determined at each of the three dialysis sessions during the week. During session 2 of each week additional specimens will be taken to analyze for hemocompatibility. At the end of the study all clearances and the hemocompatibility markers for each dialyzer will be compared to one another as well as to the manufactures stated characteristics. Blood for the clearance and removal calculations will be taken at time 0, 60 minutes and 240 minutes. Blood for the hemocompatibility determinations will be taken at time 0, 15, 30, 60 and 240 minutes. Flow rates, anticoagulant therapy, erythropoietin therapy, venous and arterial pressures will also be recorded. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05908084 -
To Compare the Efficacy and Safety of the HAV With AVF in Female Patients With End-Stage Renal Disease Requiring Hemodialysis
|
Phase 3 | |
Active, not recruiting |
NCT05309109 -
Effect of Medium Cut-Off Hemodialysis on Protein Energy Wasting: The EMCOPEW Study
|
N/A | |
Not yet recruiting |
NCT04086212 -
Ultrafiltration Efficacy of a PD Solution Containing Icodextrin-Xylitol-Carnitine
|
Phase 2 | |
Completed |
NCT01783626 -
Evaluation of Evodial Hemodialyzer Selectivity Modifications (Evodial +)
|
N/A | |
Active, not recruiting |
NCT01693263 -
Outcome of BCF Access in Hemodialysis Patients
|
||
Completed |
NCT01219959 -
Dianeal, Extraneal, Nutrineal (D-E-N) Versus Dianeal Only in Diabetic Continuous Ambulatory Peritoneal Dialysis (CAPD) Patients
|
Phase 3 | |
Completed |
NCT02278341 -
Roxadustat in the Treatment of Anemia in End Stage Renal Disease (ESRD) Patients on Stable Dialysis
|
Phase 3 | |
Completed |
NCT02593149 -
Product Evaluation for the Effectiveness of the ClearGuard® HD End Cap
|
N/A | |
Withdrawn |
NCT02274896 -
Bayston Multicenter Antimicrobial PD Catheter Safety Study
|
N/A | |
Completed |
NCT04912050 -
EXtension of Tablo TrEatmeNt Duration Registry
|
||
Recruiting |
NCT02745340 -
Substitution of Acetate by Citrate in the Bicarbonate Based Hemodialysis
|
N/A | |
Completed |
NCT02733328 -
Assessment of Plasma and NGAL for the Early Prediction of Acute Kidney Injury After Cardiac Surgery in Adults Study
|
||
Completed |
NCT04292184 -
Evaluation of Thiosulfate in End Stage Renal Disease and Kidney Transplantation
|
Phase 1 | |
Completed |
NCT02795286 -
Automated Setting of Individualized Sodium Technology
|
N/A | |
Active, not recruiting |
NCT02808208 -
Autologous Adipose Derived Mesenchymal Stem Cells (AMSC) in Reducing Hemodialysis Arteriovenous Fistula Failure
|
Phase 1/Phase 2 | |
Completed |
NCT00559767 -
Mapping of End Stage Renal Disease Genetic Susceptibility in African Americans by Admixture Linkage Disequilibrium
|
N/A | |
Completed |
NCT01594424 -
A Safety Study of Tocilizumab to Improve Transplant Rates in Highly Sensitized Patients Awaiting Kidney Transplantation
|
Phase 1/Phase 2 | |
Completed |
NCT05610683 -
Comparison of the Removal of Uremic Toxins With Medium Cut-off and Super High-flux Vitamin E-coated Dialyzers
|
N/A | |
Completed |
NCT03249532 -
Effect of Dialysis Techniques on Blood Pressure and Cardiac Function During Dialysis
|
N/A | |
Completed |
NCT02467530 -
Food Preparation Effects on Gut Bacteria in Patients on Peritoneal Dialysis
|
N/A |