Esophageal Pressure Measurement clinical trials

View clinical trials related to Esophageal Pressure Measurement.

Filter by:
  • Completed  
  • Page 1

NCT ID: NCT02036788 Completed - Clinical trials for Esophageal Pressure Measurement

Comparison of Two Tests in the Assessment of the Accuracy of Esophageal Pressure Variations Measurement During Mechanical Ventilation

Start date: December 2013
Phase: N/A
Study type: Observational

Esophageal pressure measurement, obtained with the use of an esophageal balloon catheter, is fundamental to assess mechanical characteristics of the respiratory system during mechanical ventilation. The correct positioning of the catheter (usually at the medium third of the esophagus) is crucial for an accurate measurement of esophageal pressure. Usually the correct positioning of the catheter is verified with an occlusion test (If the patient is breathing spontaneously) or with thoraco-abdominal compressions (if the patient is sedated and paralyzed). Aim of this study is to compare the accuracy of these two methods at different PEEP and esophageal catheter positions.