View clinical trials related to Endoleak.
Filter by:Surgery for abdominal aortic pathology usually occurs in the setting of advanced cardiovascular disease. The repair can be relatively simple or complex with multiple steps including open repair, placing a stent with a catheter, and placing a complicated stent that allows for crossing vessels without occluding them. All these repairs require imaging follow up. The most commonly accepted tool for follow up is Computed Tomography (CT) scan which involves ionizing radiation and potentially nephrotoxic iodinated contrast. Recommendations for the time interval for follow up, as well the radiology imaging technique vary. Routine ultrasound with Doppler, CT, and MRI has all been employed utilizing various imaging protocols. Clinicians use non-contrast CT, arterial phase and delayed phase CT, ultrasound, and various combinations based on personal experience and patient pathology. Concerns over cost, potential nephrotoxicity of contrast agents and repeated radiation exposure has led to investigation of alternate imaging modalities such as contrast-enhanced ultrasound (CEUS). CEUS represents an improvement of ultrasound imaging but comparisons against CT report widely varying results, likely due to technical factors of CEUS and limitations of single-phase CTA. Contrast ultrasound has been used effectively to diagnose leaks in the aorta post repair and is without the radiation and potential nephrotoxicity of iodinated contrast. Of yet, no large prospective studies have compared CT and contrast US and no studies have looked at the more complicated staged or fenestrated repairs. This study proposes to perform a contrast ultrasound at the same time as a contrast CT using a standardized protocol. This protocol would include a non-contrast CT, angiographic CT, and a CT in a delayed phase in all patients as standard of care. We will compare the results of a contrast US with the various data derived from a three phase CT.
The purpose of the study is to describe Sodium Fluoride uptake (using Positron Emission Tomography-Computed Tomography - PET-CT) following Endovascular Aneurysm Repair (EVAR) and to determine whether Sodium Fluoride PET-CT can predict the development of endoleaks.
Ten percent of the population above 60 years develops an aortic abdominal aneurysm. In case of rupture, this pathology leads to death in more than 70% of the cases. Over the past ten years, Endovascular Aortic Aneurysm Repair (EVAR) has been the most used technique for elective treatment for abdominal aortic aneurysms (AAA) in patients with a favorable anatomy. But despite excellent postoperative results with a significant reduction of mortality , a close follow-up of these patients is mandatory to detect any potential endoleaks particularly in patients with a long-life expectancy. Failed Endovascular Infrarenal Aortic Aneurysm Repair (EVAR) with development of a proximal endoleak exposes the patient to the risk of rupture and must be treated. This type of endoleaks are often related to dilatation of the proximal neck of the AAA, and of the suprarenal aorta, making the use of any aortic fixation system, or uncovered stent ineffective. In these cases, open surgical conversion with stent graft removal is possible but at the price of a significant morbidity and mortality. The alternative is the use of a fenestrated or branched stent graft (F/BEVAR) extending the proximal sealing zone to a non-diseased aorta. The goal of this study was to evaluate the technical feasibility, early and midterm outcomes of (F/BEVAR) in patients with a proximal endoleak following a standard EVAR. The investigators performed a multicentre study between January 2010 and December 2019 in 8 French University Centres which included 85 patients with 3 years of post operative follow-up.
Endovascular treatment has become the first choice to repair abdominal aortic aneurym, but exposes patients to a risk of endoleaks. Although treatment of type 1 and 3 endoleaks has proven to prevent aneurysms from rupture, controversies remain about type 2 endoleaks. The investigators described the different techniques of type 2 endovascular repair, and their efficacy at short and long term..
This study is set up to assess the feasibility and safety of the clinical procedure using AneuFix in a prophylactic setting at the time of EVAR endograft implantation.
To determine the safety and efficacy of IMPEDE-FX Embolization Plug and/or IMPEDE-FX Rapid Fill to fill an abdominal aortic aneurysm (AAA) sac outside of an endovascular aneurysm repair (EVAR) stent graft.
Abdominal Aortic Aneurysm (AAA) is a known vascular entity that may be life threatening condition .The most common treatment approach nowadays is the endovascular approach, a procedure known as endovascular aortic repair (EVAR). The most common procedure related complication is the expansion of the aneurysm from a "feeding vessel", usually a lumbar or intercostal artery. Another known complication is an endoleak from the stentgraft.Today, accepted EVAR follow up protocol consists of one multiple multiphasic CT angiography (CTA) scan, one month after the procedure and ultrasound exams there after . Ultrasonography is a useful method for detection and evaluation of AAA, has no ionizing radiation and is useful for the dynamic estimation of the aortic width in patients post EVAR. However, the sensitivity of ultrasonography solely for detection of endoleaks in post EVAR patients is not high.In recent years, the development of "fusion" applications allows the dual modality merge between ultrasound and CT scans that can be used as follow up examinations of known imaging findings on CT .Another application that had been developed for ultrasound machines is the ability to generate a 3 dimensional (3D) reconstruction which allows more precision. In the recent year the usage of intravenous contrast agent for ultrasonography based on microbubbles (BRACO SONOVIEW) has been approved by the Israeli ministry of health. This contrast agent is not nephrotoxic and the risk for allergic reaction is very low statistically similar to Gadolinium.A 3D contrast enhanced ultrasonography "fused" together with CTA may be a helpfull addition , which lacks radiation and odine contrast reactions and nephrotoxicity ,in the follow up in post EVAR patients , by means of identifing endoleaks at an earlier stage than by ultrasound alone. The purpose of our research is to evaluate the combined modality (fusion of CTA with CEUS) mentioned above in identifing early endoleaks in post EVAR patients and thus enabilng early intervention when needed
The study is non-randomized, multicenter international safety, performance and clinical benefit outcome assessment of ANEUFIX to treat patients with isolated type II endoleak in the presence of a growing AAA-sac following an EVAR procedure more than 6 months ago.
The EASYX™ Liquid Embolic is a new injectable, precipitating polymeric agent for the obliteration of vascular spaces through direct puncture or catheter access performed under X-ray guidance. The embolic liquid is an iodinized Polyvinyl Alcohol (PVA) Polymer ether. Iodine groups are covalently grafted to the PVA polymer backbone, whereby a stable nondegradable polymer with the desired features is created. The resulting polymer is dissolved in Dimethyl Sulfoxide (DMSO). EASYX™ is CE-marked since December 2016 and has been used in humans a few time for type II endoleaks, portal vein and varicocele (<10 cases at the date of submission). The purpose of this study is to evaluate the safety and efficacy of EASYX™ embolization liquid for the percutaneous treatment of vascular lesions, i.e. embolization of varicocele, type II endoleaks, portal vein before surgery, active peripheral bleeding or angiomyolipoma (AML).
By comparing the clinical outcome of patients underwent different hypothermic circulatory arrest (mild hypothermic versus moderate hypothermic) during aortic arch surgery, this study aims to determine the optimal hypothermic circulatory arrest strategy for aortic surgery.