Clinical Trials Logo

Clinical Trial Summary

In the Scandinavian and Swiss HEMS critical care teams, the prehospital tracheal intubations (TI) are performed by airway experts with high success rates and low rates of complications. Due to environmental conditions these are today frequently performed in-cabin before take-off. There are so far no published data on comparing outside and in-cabin TI under these circumstances. This will therefore be the first prospective study comparing prehospital TIs outside or incabin, performed by airway experts.


Clinical Trial Description

Background Seriously ill or injured patients might require prehospital TI, which is a potentially lifesaving intervention. Performing TI in a prehospital context differ from the preconditions inhospital due to environmental and technical aspects and resources available (3). Today there is a consensus that prehospital critical care should at least be on the same standards as in-hospital care. The trend therefore has been towards more rigorous safety precautions introducing Standard Operating Procedures (SOP) including 360oaccess to patients with all equipment at close hand brought out from the helicopter or the ambulance and long challenge-response lists. This will shift focus towards adherence to SOPs instead of tailoring the sequence of procedures according to circumstances and patient needs. An experienced operator can plan and communicate appropriate actions from a risk-benefit perspective in a stressful situation. Prehospital interventions have to be time effective, especially where short on-scene times are preferable in time-critical conditions such as uncontrolled internal haemorrhage and traumatic brain injuries. A recent Nordic multicentre study, PHAST, shows that emergency systems staffed with highly experienced anaesthetists can perform prehospital TI with high success rates, low incidence of complications and short on-scene times. Due to environmental factors, weather and light conditions in the Scandinavian countries, it is not always favourable to perform TI outside the helicopter or ambulance, with 360o -access. Technical aspects in-helicopter/in-ambulance such as access to better suctioning and stretcher positioning, can influence the operator's decision on where to perform the TI. Whether the location of the TI affects the outcome has not yet been studied. A recent experimental mannequin study, SPRINT, suggests that in-cabin intubations can offer equal to, or even better conditions than out of cabin and can shorten on-scene time. To investigate whether this applies to real life conditions, a prospective large-scale clinical study must be done. Performing prehospital TI is dependent on a well-functioning team where the operator has an assistant backing up during the procedures. The assistants' level of airway experience and the teams' accumulated experience working together has not been studied earlier. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04206566
Study type Observational
Source Karolinska Institutet
Contact
Status Completed
Phase
Start date March 1, 2020
Completion date September 1, 2021

See also
  Status Clinical Trial Phase
Completed NCT03277872 - NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope N/A
Suspended NCT04253795 - Nonintubated Versus Intubated Anesthesia in Video-assisted Thoracic Surgery N/A
Completed NCT02864017 - Immuno Nutrition by L-citrulline for Critically Ill Patients N/A
Completed NCT02900807 - CT-scan Airways Mensuration - Correlation to External Measurements
Completed NCT01823328 - Ketamine Versus Etomidate for Rapid Sequence Intubation Phase 4
Completed NCT02350933 - Endoscopic Evaluation of the Paediatric Airway After Prior Prolonged (>24 h) Tracheal Intubation N/A
Completed NCT01170455 - Nasal Intubation Using the Blind Intubation Device N/A
Completed NCT00980590 - Airway Scope and Macintosh Laryngoscope for Tracheal Intubation in Patients Lying on the Ground N/A
Completed NCT05515107 - The Laryngoscopic View With C-MAC Videolaryngoscope Miller Blade Lifting the Epiglottis or the Vallecula in Children N/A
Completed NCT06249659 - Impact of Extubation Location After Surgery on Perioperative Times
Completed NCT03677505 - KoMAC Videolaryngoscope for Double-lumen Intubation N/A
Completed NCT03328182 - Assessment of an Oral Endotracheal Subglottic Tube Holder N/A
Recruiting NCT02277652 - Endotracheal Intubation Devices N/A
Recruiting NCT02073786 - Rigid Video Stylet Vs Conventional Lightwand Intubation N/A
Recruiting NCT02277405 - Pediatric Intubation During Resuscitation N/A
Completed NCT02277418 - Venner a.p. Advance Video Laryngoscope N/A
Completed NCT01003327 - Comparison of the I-gel Laryngeal Mask and the Classic Laryngeal Mask in Patients With a BMI>25 Phase 4
Completed NCT00956592 - Clinical Evaluation of the Storz CMAC Laryngoscope N/A
Completed NCT00783731 - Low Dose of Midazolam is Superior to Conventional Dose for Rapid Sequence Intubation in Emergency Department (ED) N/A
Recruiting NCT03887897 - First Attempt Intubation Rate With Airtraq vs Macintosh Direct Laryngoscope N/A