Edentulous Mouth Clinical Trial
Official title:
Electromyographic Activity, Accuracy, Patient Satisfaction and Retention of Conventional Versus 3-D Printed Maxillary Complete Denture: A Cross-over Randomized Controlled Trial
Verified date | April 2023 |
Source | Al-Azhar University |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
Analyzing and comparing the retention, accuracy, EMG and patient satisfaction of maxillary complete denture base fabricated by conventional and rapid prototyping techniques.
Status | Completed |
Enrollment | 10 |
Est. completion date | December 1, 2022 |
Est. primary completion date | August 1, 2022 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 50 Years to 75 Years |
Eligibility | Elligibility Criteria: Inclusion Criteria: - Completely edentulous patients were selected to have their ridges covered with firm, thick and compressible mucosa - All patients accepting prosthodontic treatment by an removable denture. Exclusion Criteria: - TMJ disorder. - Limited mouth opening or mandibular movement - Muscle spasm or tenderness - Mandibular deviation |
Country | Name | City | State |
---|---|---|---|
Egypt | Faculty of Dentistry, AlAzhar University for Girls | Cairo |
Lead Sponsor | Collaborator |
---|---|
Al-Azhar University |
Egypt,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Other | Accuracy | The fitting surfaces of each upper denture was sprayed and scanned after finishing and before delivery, then was saved as an STL file after flipping of the denture's fitting surface to resemble the cast surface. Geomagic software was used to evaluate the accuracy at which the master cast STL file was selected as a reference data and the STL file of the flipped fitting surface of the denture was selected as a measured data. Both files were automatically aligned together by selecting the "best fit alignment "icon. The accuracy of the denture bases generated in a color map according to the 3D deviation between the denture base and reference data. Blue color indicates negative deviation (tissue compression), yellow to red color indicates positive deviation (misfit with space) while green color indicates measured deviation below 0.2mm. | up to 1 week | |
Other | Electromyography Change | The electromyographic activity was recorded for each patient by Nemus 2 machine. Washing period of 2 weeks between each denture as the same in masticatory efficiency and recorded as follow: The electromyographic activity was performed by measuring muscle activity of the masseter muscle on both sides | 3 months | |
Other | Change of Patient satisfaction | Patient satisfaction was investigated through a questionnaire, which was given to the patients. Evaluation of patient satisfaction was measured using the visual analogue scale (VAS) in which patients scored their answers using a scale from 0 to 10 cm (low/worst to high/best). | 3 months | |
Primary | Change of Retention | Retention was measured for both groups using the universal testing machine. Modification in each denture was made where two small metal tubes (3 mm diameters) were placed a few millimeters above the laterals in maxillary dentures by self-cure acrylic resin. The distance between the right tube and the geometric center was almost the same distance as between the left tube and the geometric center. The exact distance was checked using an orthodontic wire. | 3 months |
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT04984499 -
In Vivo Clinical Investigation of the Safety and Performance of Dental Implants TBR® Tissue Level Z1
|
||
Completed |
NCT01411683 -
Mandibular Overdentures Retained by Conventional or Mini Implants
|
N/A | |
Completed |
NCT04853459 -
A Technique for Border Molding in Complete Dentures Using Light-Cured
|
N/A | |
Not yet recruiting |
NCT06458738 -
Clinical Evaluation of a New Printable Denture Base Material
|
N/A | |
Completed |
NCT01230320 -
Simplified vs. Conventional Methods for Complete Denture Fabrication
|
N/A | |
Completed |
NCT05614635 -
Safety and Technical Performance of Plastalgin and Plastalgin Fast in Patients Requiring a Dental Impression
|
||
Active, not recruiting |
NCT05599269 -
Retrospective Clinical Evaluation of Nano-hybrid-composite Denture Teeth
|
N/A | |
Not yet recruiting |
NCT03674554 -
Prosthetic Complications of Screw Retained Restoration
|
N/A | |
Not yet recruiting |
NCT06155630 -
3D Printing for the Fabrication of Mandibular Implant Overdentures
|
N/A | |
Active, not recruiting |
NCT02117856 -
Complete Lower Dentures on 1 or 2 Implants
|
N/A | |
Not yet recruiting |
NCT06393582 -
Accuracy Evaluation of Implant Impressions: A Prospective Study
|
N/A | |
Recruiting |
NCT05375045 -
Real-life Evaluation of the Safety and Performance of EUROTEKNIKA Dental Implants
|
||
Recruiting |
NCT06255522 -
Clinical and Anatomical Factors Influencing Accuracy in Fully Guided Implant Placement.
|
N/A | |
Completed |
NCT04760457 -
Mandibular Overdentures Retained by Mini Implants: a Clinical Trial Comparing Different Surgical and Loading Protocols
|
N/A | |
Completed |
NCT03126942 -
Single-implant Overdentures Retained by the Novaloc Attachment System
|
N/A | |
Enrolling by invitation |
NCT05441527 -
Use of Two Dissolvable Therapeutics Under Removable Partial Dentures
|
N/A | |
Completed |
NCT03056976 -
Cost-effectiveness of Implant Treatment for the Edentulous Mandible
|
N/A | |
Completed |
NCT04475913 -
Digital vs Analog Impression in Cases of All-on-4 - Prosthesis
|
N/A | |
Recruiting |
NCT03536468 -
Psychological Impact of Tooth Loss
|
||
Completed |
NCT03048812 -
Attachment Types for Single-implant Mandibular Overdentures: a Crossover Clinical Trial
|
N/A |