Clinical Trials Logo

Clinical Trial Summary

- Steps in short: Undergoing the conventional steps of maxillary single denture construction till the step of framework construction that will be designed and constructed using CAD/CAM after optical scanning of the master cast ( 2 frameworks to cover the palate and crest of the ridge : one made of titanium and the other made of cobalt/chromium) then conventional steps will be undergone including bite, Try-in and delivery ending by measuring the denture retention.

- Number of visits & follow up period :

Visits: will be 5-6 visits for each patient. Follow up period: 6.5 months (immediately post-insertion then after 1 week then after 3 months for the first type then 2 weeks washout period and the same for the second type)


Clinical Trial Description

The study will be carried out in the department of prosthodontics-cairo university. Patients will be selected from the out-patient clinic according to the inclusion criteria, The primary impression will be made with alginate (cavex-normal set) and will be border-molded to get the acceptable extension and border thickness, a tray will be prepared with self-activated acrylic resin over the study cast. A secondary impression will be made with heavy putty consistency as a border molding material and the final impression will be made with light rubber base (3M) impression material, Then Pouring of the final impressions with type 4 Hydrocal dental stone (Hydrocal Dental stone, Bayer, and Germany). Master casts will be optically scanned using 3 shape optical scanner. Duplication of master casts will be done using silicone duplicating material. Titanium and cobalt/chromium metallic bases will be milled using 3shape milling machine to cover the palate with mesh extension over the ridge. They will be tried intra-orally regarding sitting and stability. Occlusal rim will be set on titanium metallic base then face bow record will be recorded then mounting the maxillary master cast. Centric relation will be registered then mounting of the mandibular cast will be done. The same will be done for the duplicate cast with the Cobalt/Chromium metallic base. Then Setting of the anatomical teeth for both master casts then try-in stage will be checked intra-orally then packing of cast and duplicate cast with conventional heat cured acrylic resin (Dentsply, Dentsply limited, Weybridge, Surrey. England) after flasking each denture will be finished.

The dentures will be delivered, then the assessment will be immediately and after 1 week then after 3 months that a hook screw with its nut (Digital force gauge instrument, model 475044) will be secured in the polished mid-palatal surface of the upper denture using metallic adhesive to record the amount of the force required for dislodgment. The pull end of the digital force gauge device will be connected to the hook positioned at maxillary dentures for one type of the two dentures and will be pulled vertically until denture dislodgement occurred, then the patient will take off his first type of denture for 2 weeks as a washout period then the second type of denture will be delivered and the same assessment will be done. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03675594
Study type Interventional
Source Cairo University
Contact Amal el rekaby, professor
Phone 0122258794
Email prosthetic@dentistry.cu.edu.eg
Status Not yet recruiting
Phase N/A
Start date December 1, 2018
Completion date September 30, 2019

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04984499 - In Vivo Clinical Investigation of the Safety and Performance of Dental Implants TBR® Tissue Level Z1
Completed NCT01411683 - Mandibular Overdentures Retained by Conventional or Mini Implants N/A
Completed NCT04853459 - A Technique for Border Molding in Complete Dentures Using Light-Cured N/A
Completed NCT01230320 - Simplified vs. Conventional Methods for Complete Denture Fabrication N/A
Completed NCT05614635 - Safety and Technical Performance of Plastalgin and Plastalgin Fast in Patients Requiring a Dental Impression
Active, not recruiting NCT05599269 - Retrospective Clinical Evaluation of Nano-hybrid-composite Denture Teeth N/A
Not yet recruiting NCT03674554 - Prosthetic Complications of Screw Retained Restoration N/A
Not yet recruiting NCT06155630 - 3D Printing for the Fabrication of Mandibular Implant Overdentures N/A
Active, not recruiting NCT02117856 - Complete Lower Dentures on 1 or 2 Implants N/A
Not yet recruiting NCT06393582 - Accuracy Evaluation of Implant Impressions: A Prospective Study N/A
Recruiting NCT05375045 - Real-life Evaluation of the Safety and Performance of EUROTEKNIKA Dental Implants
Recruiting NCT06255522 - Clinical and Anatomical Factors Influencing Accuracy in Fully Guided Implant Placement. N/A
Completed NCT04760457 - Mandibular Overdentures Retained by Mini Implants: a Clinical Trial Comparing Different Surgical and Loading Protocols N/A
Completed NCT03126942 - Single-implant Overdentures Retained by the Novaloc Attachment System N/A
Enrolling by invitation NCT05441527 - Use of Two Dissolvable Therapeutics Under Removable Partial Dentures N/A
Completed NCT03056976 - Cost-effectiveness of Implant Treatment for the Edentulous Mandible N/A
Completed NCT04475913 - Digital vs Analog Impression in Cases of All-on-4 - Prosthesis N/A
Recruiting NCT03536468 - Psychological Impact of Tooth Loss
Completed NCT03048812 - Attachment Types for Single-implant Mandibular Overdentures: a Crossover Clinical Trial N/A
Recruiting NCT02339194 - Application of a Simplified Method of Complete Denture Fabrication for Severely Resorbed Mandibular Ridges Phase 3