Edentulous Alveolar Ridge Clinical Trial
Official title:
Monolithic Zirconia Single Tooth Implant-supported Restorations With CAD/CAM Titanium Abutments in the Posterior Region: A 5-year Prospective Case Series Study
- Background There is a growing interest in restoring function in the posterior maxilla and mandible with dental implants. Next to this, these implants must be restored with crowns which are subject to minimal complications. Companies have introduced the option of screw-retaining and zirconia as crown material. The combination of posterior implants and screw-retained zirconia crowns are widely used, but prospective research on clinical performance and patient centered outcomes are scarce. Even more, 5-years data are lacking. - Main research question To evaluate the clinical performance of Astra Tech Implants EV and Atlantis CustomBase Abutments with full-contour zirconia Atlantis Crowns in the posterior maxilla and mandible. The primary objective of the study is marginal bone level changes by radiological assessments at 5-years follow-up. Secondary objectives are implant and restoration survival, condition of peri- implant mucosa and patients' satisfaction. - Design (including population, confounders/outcomes) The study design is an observational study of a group of patients which were treated 5 years ago with a dental implant and a screw-retained implant-supported zirconia restoration because of a missing tooth in the posterior region. Outcomes: primary outcome is the change in marginal peri-implant bone level 5 years after placing the definitive restoration. Secondary outcome measures will be implant and restoration survival, peri-implant mucosa health and patients' satisfaction using a questionnaire.
• Introduction and rationale Nowadays, the use of dental implants for oral rehabilitation is a generally accepted treatment modality. During the first years of implant dentistry, dental implants were used mainly for the restoration of edentulous mandibles with implant-supported prostheses. Yet, there is a shift towards the application of dental implants for single-tooth replacements, supported by long-term studies reporting excellent survival rates. Not only in the aesthetic region, but also in the posterior maxilla and mandible there is a growing interest in restoring function. Dental implants show a good performance in the posterior region; in recent years attention has been shifted towards a better initial stability to reduce treatment time. Next to this, implants must be restored with crowns which are subject to minimal complications. Specially for the posterior region, companies have introduced the option of screw-retaining and zirconia as crown material, of which less technical complications are mentioned. The combination of posterior implants and screw-retained zirconia crowns are widely used, but prospective research on clinical performance and patient centered outcomes are scarce and 5-years results are lacking. RESEARCH QUESTION To evaluate the clinical performance of Astra Tech Implants EV and Atlantis CustomBase Abutments with full-contour zirconia Atlantis Crowns in the posterior maxilla and mandible after a 5-years follow-up. STUDY DESIGN The study design is an observational study of a group of 50 patients which were treated 5 years ago with a dental implant and a screw-retained implant-supported zirconia restoration because of a missing tooth in the posterior region. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05769673 -
Soft and Hard Tissue Changes Around Implants
|
N/A | |
Active, not recruiting |
NCT06034067 -
Osseodensification Versus Conventional Drilling for Implant Site Preparation
|
N/A | |
Not yet recruiting |
NCT05513170 -
Closed Sinus Tenting Using Densah Burs Osteotomy Versus Conventional Osteotomy in Localized Pneumatization
|
N/A | |
Recruiting |
NCT05366985 -
Dimensional Changes of the Labial Alveolar Ridge After Socket Shield Technique With Computer Guided Root Sectioning
|
N/A | |
Completed |
NCT04543292 -
Clinical Evaluation of Polytetrafluoroethylene (PTFE, MATFILL) for the Sealing of Prosthetic Chimneys.
|
N/A | |
Not yet recruiting |
NCT04438616 -
Comparison of Patient Satisfaction and Primary Implant Stability Between Two Different Magnetic Attachment
|
N/A | |
Recruiting |
NCT05260892 -
Incisors Single-Unit Rehabilitation With Narrow GM Implants
|
||
Completed |
NCT06157047 -
Evaluation of the Crestal Bone Expansion Obtained With the Magnetic Mallet® During the Preparation of the Implant Site
|
N/A | |
Not yet recruiting |
NCT03674554 -
Prosthetic Complications of Screw Retained Restoration
|
N/A | |
Recruiting |
NCT05717478 -
Regeneration of Alveolar Sockets With rhBMP-2-loaded Bovine Bone Mineral
|
N/A | |
Recruiting |
NCT05081284 -
Clinical Outcomes of Immediate Implants With or Without a Volume-stable Collagen Matrix
|
N/A | |
Completed |
NCT04111250 -
Crestal vs Lateral Sinus Lift Augmentation
|
N/A | |
Recruiting |
NCT05141331 -
Comparison of Piezoelectric Split-crest Technique Versus Expansion Using Hand Driven Ridge Expanders in Treatment of Maxillary Narrow Ridges
|
N/A | |
Not yet recruiting |
NCT04766255 -
Behavioral Comparison of Three Different Graft Materials to Increase Soft Tissue Thickness Around Dental Implants.
|
Phase 4 | |
Completed |
NCT03714139 -
Immediate Loading a Histological Study
|
N/A | |
Completed |
NCT06182670 -
The Role of a New Prosthodontics Device in Hard and Soft Tissue Changes After Subcrestal Implant Placement
|
N/A | |
Completed |
NCT05821673 -
Soft Tissue Integration of Different Abutment Surfaces
|
N/A | |
Recruiting |
NCT04915677 -
Edentulous Sites Augmented With Collagen Matrix or CTG
|
N/A | |
Not yet recruiting |
NCT06449443 -
Zero Echo Time MR for the Assessment of Maxillary Sinus and Dental Regions
|
||
Recruiting |
NCT06012071 -
Two-piece Zirconia Implants With Two Various Platforms
|
N/A |