Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT00641576
Other study ID # W050404001
Secondary ID
Status Completed
Phase N/A
First received March 17, 2008
Last updated July 18, 2013
Start date April 2005
Est. completion date September 2010

Study information

Verified date July 2013
Source University of Alabama at Birmingham
Contact n/a
Is FDA regulated No
Health authority United States: Institutional Review Board
Study type Observational

Clinical Trial Summary

Dental implants are small metal posts that look like miniature screws. They are surgically implanted into the jawbone where they serve as substitute tooth roots. Implants are used in dentistry to reestablish function and aesthetics to areas of the mouth were natural teeth are missing.

Classical dental implants are made in two pieces. One part anchors in the jawbone and one part serves as a connecting post (an abutment) that attaches to a crown restoration or to attachment clasps that hold a denture in place.

Occasionally the materials used to fasten the two implant components together work their way loose and over time the abutment may begin to disconnect. If this happens a small gap appears between the implant and abutment. There are many reasons why this loosening occurs. One reason may be the design of the implant itself and another may be the way the two components are fastened together.

This study will assess the performance of an implant with a new design. The investigators hypothesize that using this implant design will reduce the risk of an implant-abutment disconnect and improve long-term success of implant therapy.


Description:

While the external hex dental implant design has had very good clinical success, it is limited by retention screw loosening at the junction of the implant fixture and abutment; a situation that leads to micro-movement between components.

A number of clinical complications may arise when implant components separate. Micro-movement between the implant abutment and seating platform is thought to contribute to the formation of a "biological gap", the most notable consequence being gradual resorption of crestal alveolar bone over time.

We hypothesize that the "ACE CONNECT" two-piece implant design with an internal connection will limit screw loosening by providing a stable junction between the body of the implant and the abutment; a more stable junction will limit micro-movement and prevent the formation of a gap between components. Limiting the gap will lead to less inflammation of peri-implant soft tissues and reduced resorption of bone adjacent to the implant.


Recruitment information / eligibility

Status Completed
Enrollment 23
Est. completion date September 2010
Est. primary completion date September 2010
Accepts healthy volunteers Accepts Healthy Volunteers
Gender Both
Age group 19 Years to 75 Years
Eligibility Inclusion Criteria:

- Need for replacement of non-adjacent missing teeth with dental implants

- Edentulous in the area for more than 2 months

- Minimum native bone height and width to receive a 10mm X 4mm implant

Exclusion Criteria:

- Untreated decay or periodontal disease in residual dentition

- Need for bone or soft-tissue augmentation in the proposed implant site

- Pregnancy

- Consistent use of medications likely to compromise bone healing

- Chronic disease condition likely to compromise bone healing

- Consistent smoking over 10 cigarettes during the immediate past 6 months

Study Design

Observational Model: Case-Only, Time Perspective: Prospective


Related Conditions & MeSH terms


Intervention

Device:
ACE CONNECT Endosseous dental implant
Subjects in this study receive ACE CONNECT Internal-Connection dental implants to: 1)replace a missing tooth in an edentulous area of the maxilla or mandible restored with a single-unit crown (may include up to two non-adjacent areas as study sites) or, 2)subjects with an edentulous mandible will receive two implants placed in the lower canine position and restored with an implant-retained removable over-denture. Subjects will return for four follow-up evaluations scheduled at 6, 12, 18 and 24 months after delivery of the permanent restoration.

Locations

Country Name City State
United States University of Alabama at Birmingham School of Dentistry Birmingham Alabama

Sponsors (2)

Lead Sponsor Collaborator
University of Alabama at Birmingham ACE Surgical Supply, Inc.

Country where clinical trial is conducted

United States, 

References & Publications (14)

Becker W, Becker BE. Replacement of maxillary and mandibular molars with single endosseous implant restorations: a retrospective study. J Prosthet Dent. 1995 Jul;74(1):51-5. — View Citation

Binon PP. Evaluation of the effectiveness of a technique to prevent screw loosening. J Prosthet Dent. 1998 Apr;79(4):430-2. — View Citation

Brägger U, Häfeli U, Huber B, Hämmerle CH, Lang NP. Evaluation of postsurgical crestal bone levels adjacent to non-submerged dental implants. Clin Oral Implants Res. 1998 Aug;9(4):218-24. — View Citation

Goodacre CJ, Kan JY, Rungcharassaeng K. Clinical complications of osseointegrated implants. J Prosthet Dent. 1999 May;81(5):537-52. Review. — View Citation

Hurson S. Laboratory techniques to prevent screw loosening on dental implants. J Dent Technol. 1996 Apr;13(3):30-7. — View Citation

Jemt T, Book K, Lindén B, Urde G. Failures and complications in 92 consecutively inserted overdentures supported by Brånemark implants in severely resorbed edentulous maxillae: a study from prosthetic treatment to first annual check-up. Int J Oral Maxillofac Implants. 1992 Summer;7(2):162-7. — View Citation

Jemt T, Laney WR, Harris D, Henry PJ, Krogh PH Jr, Polizzi G, Zarb GA, Herrmann I. Osseointegrated implants for single tooth replacement: a 1-year report from a multicenter prospective study. Int J Oral Maxillofac Implants. 1991 Spring;6(1):29-36. — View Citation

Kallus T, Bessing C. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants. 1994 Mar-Apr;9(2):169-78. — View Citation

Lazzara R, Siddiqui AA, Binon P, Feldman SA, Weiner R, Phillips R, Gonshor A. Retrospective multicenter analysis of 3i endosseous dental implants placed over a five-year period. Clin Oral Implants Res. 1996 Mar;7(1):73-83. — View Citation

Lekholm U, Zarb G. Patient selection and preparation. In Branemark P-I, Zarb GA and Albrektsson T. eds. Tissue Integrated Prosthesis: Osseointegration in Clincal Dentistry. Chicago: Quintessence 1985 pp 199-209

McGlumphy EA, Mendel DA, Holloway JA. Implant screw mechanics. Dent Clin North Am. 1998 Jan;42(1):71-89. Review. — View Citation

Naert I, Quirynen M, van Steenberghe D, Darius P. A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects. J Prosthet Dent. 1992 Dec;68(6):949-56. — View Citation

Weber HP, Buser D, Fiorellini JP, Williams RC. Radiographic evaluation of crestal bone levels adjacent to nonsubmerged titanium implants. Clin Oral Implants Res. 1992 Dec;3(4):181-8. — View Citation

Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: Problems and complications encountered. J Prosthet Dent. 1990 Aug;64(2):185-94. — View Citation

* Note: There are 14 references in allClick here to view all references

Outcome

Type Measure Description Time frame Safety issue
Primary Junctional stability between device and abutment 24 months No
Secondary Peri-implant osseous support of the device 24 months No
Secondary Peri-implant soft-tissue response to the device 24 months No
See also
  Status Clinical Trial Phase
Completed NCT00780273 - Success Rate of Immediately Loaded Implants With Platform Switched Design Placed in Anterior Part of Mandible and Restored With Fixed Prostheses Phase 4
Completed NCT00807456 - Study to Evaluate an Implant With a Sloped Top in Patients With a Sloped Jaw Bone N/A
Not yet recruiting NCT06018701 - A Clinical Trial of Dental Device Cemented With Polymethyl Methacrylate (PMMA) Bone Cement Early Phase 1
Completed NCT00868777 - The Influence of Dimensional Anatomic Variables on the Outcomes of Maxillary Sinus Grafting Procedures Phase 4
Recruiting NCT06287346 - 5-Years PMCF Study of Ceramic Dental Implants One-piece Versus Two-piece.
Active, not recruiting NCT03845335 - Clinical Performance Evaluation of Two Different Dental Implants N/A
Completed NCT01340170 - A Study Evaluating OsseoSpeed TX Using Different Drilling Protocols With Immediate Loading N/A