Dry Eye Clinical Trial
Official title:
Comparison of Autologous Serum Versus Preservative Free Artificial Tear in Patients With Dry Eye Due to Systemic Isotretinoin Therapy
Verified date | April 2016 |
Source | Nigde State Hospital |
Contact | n/a |
Is FDA regulated | No |
Health authority | Turkey: Ethics Committee |
Study type | Interventional |
Dry eye is a significant adverse effect of isotretinoin causing patients to use ophthalmic medications. For this reason, many patients using isotretinoin are referred to ophthalmology clinic because of discomfort symptoms. In the literature, there are studies suggesting superiority of Autologous serum drops regarding effects on ocular surface when compared to artificial tear. In addition, Autologous serum was also used in several corneal pathologies with successful outcomes. No data regarding use in the ocular adverse effects of isotretinoin was found in the literature; however, investigators think that it may be an effective alternative in the treatment of dry eye developed during isotretinoin use due to positive effects on ocular surface, epithelial regeneration and anti-inflammatory effect. Autologous serum can be a choice of ophthalmologists in routine practice by increasing number of comprehensive studies investigating effectiveness, safety and long-terms effects of Autologous serum therapy.In this study, it was aimed to investigate dry eye development in the patients receiving systemic retinoic acid therapy and to compare effectiveness of Autologous serum and Preservative free artificial tear in the patients with dry eye disease.
Status | Completed |
Enrollment | 24 |
Est. completion date | March 2016 |
Est. primary completion date | March 2016 |
Accepts healthy volunteers | No |
Gender | Both |
Age group | 18 Years to 35 Years |
Eligibility |
Inclusion Criteria • isotretinoin use for any reason Exclusion Criteria: - corneal pathologies such as dry eye illness before isotretinoin treatment - previous cornea surgery, injury or keratitis - active ocular infection - meibomian gland dysfunction - excessive allergic reaction that may be associated with dry eye - glaucoma therapy use - severe anemia - previously use of PFAT or AS for any reason - (Hb<10 g/dL) and elevated hepatic function tests requiring withdrawal of therapy |
Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Crossover Assignment, Masking: Double Blind (Subject, Outcomes Assessor), Primary Purpose: Treatment
Country | Name | City | State |
---|---|---|---|
Turkey | Nigde State Hospital | Nigde |
Lead Sponsor | Collaborator |
---|---|
Nigde State Hospital |
Turkey,
Egger SF, Huber-Spitzy V, Böhler K, Scholda C. [Isotretinoin administration in treatment of acne vulgaris. A prospective study of the kind and extent of ocular complications]. Ophthalmologe. 1995 Feb;92(1):17-20. German. — View Citation
Kojima T, Ishida R, Dogru M, Goto E, Matsumoto Y, Kaido M, Tsubota K. The effect of autologous serum eyedrops in the treatment of severe dry eye disease: a prospective randomized case-control study. Am J Ophthalmol. 2005 Feb;139(2):242-6. — View Citation
Oner AF, Ferahbas A, Karakucuk S, Utas S, Karaman B, Kutlugun C et al. Ocular side effects associated with systemic isotretinoin. Cutan Ocul Toxicol. 2005;23:189-195.
Tananuvat N, Daniell M, Sullivan LJ, Yi Q, McKelvie P, McCarty DJ, Taylor HR. Controlled study of the use of autologous serum in dry eye patients. Cornea. 2001 Nov;20(8):802-6. — View Citation
Urzua CA, Vasquez DH, Huidobro A, Hernandez H, Alfaro J. Randomized double-blind clinical trial of autologous serum versus artificial tears in dry eye syndrome. Curr Eye Res. 2012 Aug;37(8):684-8. doi: 10.3109/02713683.2012.674609. Epub 2012 Jun 6. — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Change in Schirmer Test I in Patients with Dry Eye due to isotretinoin use after autologous serum or preservative free artificial tears treatment | Schirmer Test I is used for Dry Eye evaluation before and after autologous serum or preservative free artificial tears treatment. Schirmer test is used to measure tear secretion. Schirmer strips are used for this test. Wetting of the paper is recorded in millimeter | up to 3 Months monthly measurements were done | Yes |
Primary | Change in Break up Time in Patients with Dry Eye due to isotretinoin use after autologous serum or preservative free artificial tears treatment | fluorescein sodium eye drops was used for measurement of Break up Time. Value of Break up Time for per eye is recorded as seconds | up to 3 Months monthly measurements were done | Yes |
Primary | Change in Ocular surface Disease Index in Patients with Dry Eye due to isotretinoin use after autologous serum or preservative free artificial tears treatment | OSDI score is a reliable and feasible test which is commonly used for dry eye patients to grade either dry eye symptom severity and its effect on vision-related function. In this index, people are asked to indicate whether they experienced any of the symptoms or problems due to drye eye, if so, how often. Every question asked to patients is scored from one to four according to the frequency of symptoms. The scores were collected from all the questions. | up to 3 Months monthly measurements were done | Yes |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT05102409 -
An Exploratory Clinical Trial to Assess Safety and Tolerability in Subjects With Dry Eye Disease
|
Phase 2 | |
Completed |
NCT05027087 -
The Effect of a Novel Blueberry Supplement on Dry Eye Disease
|
Phase 3 | |
Completed |
NCT06159569 -
Performance and Tolerability of the Medical Device LACRIACT
|
N/A | |
Completed |
NCT04081610 -
Clinical Trial to Evaluate the Safety and Tolerability of Lagricel® Ofteno Multi-dose Ophthalmic Solution
|
Phase 1 | |
Completed |
NCT05062564 -
Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye
|
N/A | |
Completed |
NCT05825599 -
PMCF Study to Evaluate Performance and Safety of "HPMC-based Eyedrops" Used to Relieve Dry Eye Symptoms
|
N/A | |
Completed |
NCT03418727 -
Dry Eye Disease Study With Brimonidine
|
Phase 2 | |
Active, not recruiting |
NCT04425551 -
Effect of Micropulse Laser on Dry Eye Disease Due to Meibomian Gland Dysfunction
|
N/A | |
Recruiting |
NCT04527887 -
Intracanalicular Dexamethasone Insert for the Treatment of Inflammation and Discomfort in Dry Eye Disease (DEcIDED)
|
Phase 4 | |
Not yet recruiting |
NCT06379685 -
Study to Evaluate the Safety and Tolerability of PRO-190 Ophthalmic Solution Compared to Systane Ultra® on the Ocular Surface.
|
Phase 1 | |
Active, not recruiting |
NCT05618730 -
Safety, Tolerability, Plug Retention and Preliminary Efficacy of Tacrolimus-loaded Punctal Plug in Patients With Moderate to Severe Dry Eye Disease - Cohort B
|
Phase 1 | |
Completed |
NCT04553432 -
Dry Eye OmniLenz Application of Omnigen Research Study
|
Phase 4 | |
Recruiting |
NCT04109170 -
Dry Eye Evaluation System Based on Bioinformatics
|
||
Completed |
NCT04105842 -
Refitting Daily Disposable Contact Lens Wearers With Dry Eye Disease With A Different Daily Disposable Lens Type
|
N/A | |
Completed |
NCT05505292 -
Lifitegrast 5% for the Treatment of Dry Eye In Habitual Soft Contact Lens Wearers
|
Phase 4 | |
Completed |
NCT04668131 -
Study on Curative Effect and Mechanism of Acupuncture on Neuropathic Pain in Dry Eye Disease
|
N/A | |
Completed |
NCT06176651 -
Evaluation of Miebo (Perfluorohexyloctane) Eyedrops in Habitual Contact Lens Wearers
|
Phase 4 | |
Not yet recruiting |
NCT02218827 -
Topical Steroid Treatment For Dry Eye
|
N/A | |
Completed |
NCT02235259 -
Efficacy and Safety of XG-104 for the Treatment of Dry Eye
|
Phase 2 | |
Completed |
NCT01959854 -
Efficacy of Topical 0.2% Xanthan Gum in Patients With Dry Eye
|
N/A |