Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT04287257
Other study ID # 0597-19-TLV
Secondary ID
Status Not yet recruiting
Phase N/A
First received
Last updated
Start date March 1, 2020
Est. completion date March 1, 2022

Study information

Verified date February 2020
Source Tel-Aviv Sourasky Medical Center
Contact Reut Wengier
Phone 36974720
Email reutw@tlvmc.gov.il
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Distal radial fractures (DRF) are the most common fractures encountered in health care. Annualized estimates in the United States alone suggest an incidence of approximately 640,000 cases, and rising, per year. Most fractures may be treated in a plaster cast, but unstable fractures tend to displace without a surgical procedure. 1

Pulsed electromagnetic field (PEMF) is one modality commonly used to stimulate bone generation throughout various clinical settings including orthoapedic surgery. PEMF has been shown to primarily effect vascular generation, formation and neovascularization2,3. This may help decrease time to healing and allow patients to return to normal activities sooner.

Additional study demonstrated that PEMF exposure increased cell proliferation, adhesion and the osteogenic commitment of MSCs, even in inflammatory conditions. In this in-vitro model PEMFs increased the expression of anti-inflammatory cytokines, such as IL-10, and reduced the expression of the pro-inflammatory cytokine IL-1 4.

The distal radius fracture was chosen as the model to test the effects of PEMF treatment because it includes both trabecular and cortical bone, is accessible for radiographs, has little soft tissue that can distort the radiograph, and is amenable to multiple functional endpoints.

The purpose of the study is to determine whether the use of FHP by means of pulsed electromagnetic fields in acute distal radius fractures will accelerate healing both clinically and radiotralogically


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 50
Est. completion date March 1, 2022
Est. primary completion date March 1, 2021
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria:

1. Subjects with closed unilateral dorsally angulated fracture of the distal radius (Colles') visible by x-ray.

2. Subjects treated conservatively by immobilization ± closed reduction

3. Age >18 years

4. Subjects able to adhere to the visit schedule and protocol requirements and be available to complete the study.

Exclusion Criteria:

1. Subjects with intra articular fracture or extra-articular fracture that meets the criteria for operative fracture fixation.

2. Subjects with pins or plates in the wrist

3. Sustained previous fractures or bone surgery in the currently fractured distal forearm

4. Synovial pseudarthrosis

5. Subjects with multiple trauma (several fractures at once)

6. Subjects suffering from joint diseases that affect the function of the wrist and/or hand of the injured arm.

7. Pregnancy

8. Women who are breast-feeding.

9. Women of childbearing potential and not using a medically accepted form of contraception when sexually active.

10. presence of a life supporting implanted electronical device

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Fracture Healing Patch (FHP)
The Fracture Healing Patch (FHP) is an external silicone patch that contains inside micro-electronic modulus, which generates a pulsed electromagnetic field (PEMF) to enhance and improve fracture healing. The FHP is placed under the cast at the fracture site. Throughout the treatment period the FHP produces a pulsed electromagnetic field. The FHP houses a battery, a microelectronic module and a coil that produce the PEMF.

Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
Tel-Aviv Sourasky Medical Center

Outcome

Type Measure Description Time frame Safety issue
Primary Change from baseline in radiographic fracture healing Change from baseline in radiographic fracture healing will be measured. Radiographic healing will be defined as the interval in days between the occurrence of the fracture and the time when bridging in three of four cortices is seen on X-ray images. A measurement will be made at each follow up evaluation by using Radius Union Scoring System (RUSS) score Radiographic images (X-ray) will be performed for each subject from day 0 and onward: week 2,4, 6 and 12.
Secondary Change from baseline in improvement of function For assessment of functional deficit, disability and pain level, the Patient Rated Wrist Evaluation (PRWE) will be used. The PRWE is an easy 15-item questionnaire designed to measure wrist pain and disability in activities of daily living. The PRWE allows patients to rate their levels of wrist pain and disability.
Pain Score = Sum of the 5 pain items (out of 50) Best Score = 0, Worst Score = 50 Function Score = Sum of the 10 function items, Divided by 2 (out of 50) Best Score = 0, Worst Score = 50 Computing the Total Score Total Score = Sum of pain + function scores Best Score = 0, Worst Score = 100
Functional assessment will be performed at 4, 6 and 12 weeks from treatment
See also
  Status Clinical Trial Phase
Recruiting NCT05736068 - Is Casting of Displaced Pediatric Distal Forearm Fractures Non-inferior to Reduction in General Anesthesia? N/A
Completed NCT04554472 - Usefulness of Intraoperative Ultrasound in a Volar Plate Distal Radius Fixation
Completed NCT03613922 - Effects of Early Manual Therapy on Functional Outcomes After Volar Plating of Distal Radius Fractures N/A
Completed NCT01823692 - Evaluating Validity of Ultrasonography in Determining Distal Radius Fracture Reduction Phase 2
Completed NCT02286661 - Short-Arm Casting Effective in Type A2 Fractures in the Distal Radius N/A
Completed NCT01062997 - Volar Locked Plating Versus Bridging External Fixation N/A
Not yet recruiting NCT04100317 - Spanning Bridged Plate in Comminuted Distal Radius Fractures
Recruiting NCT04976335 - Quantitative and Clinical Assessment of Flexor Tendon Gliding Following Application of a Bioresorbable Hydrogel: A Prospective, Randomized Study in Patients Undergoing Distal Radius Fracture Repair N/A
Completed NCT03635060 - Distraction Osteogenesis for Distal Radius Fractures vs. Volar Plating N/A
Not yet recruiting NCT05095415 - Occupational Therapy Pre-operative Education in the Orthopedic Hand Setting N/A
Terminated NCT02744352 - Single Shot vs Catheter Infraclavicular Brachial Plexus Block After Distal Radius Fracture Repair N/A
Completed NCT05558306 - Radiological vs Clinical Outcome in DRF N/A
Completed NCT01778673 - Cortical Comminution and Intra-articular Involvement in Distal Radius Fractures Can Predict Radiological Outcome. A Prospective Multicenter Study N/A
Active, not recruiting NCT03349216 - Bier's Block Versus Systemic Analgesia Phase 2
Completed NCT04357470 - Manual Dexterity in Ulnar Styloid Fracture Patients N/A
Completed NCT05360836 - The Effect of Motor Imagery in Patients With Radius Distal End Fracture N/A
Recruiting NCT02957240 - Graded Motor Imagery for Women at Risk for Developing Type I CRPS Following Closed Treatment of Distal Radius Fractures N/A
Completed NCT03240471 - Cast OFF Trial: One Versus Four-five Weeks of Plaster Cast Immobilization N/A
Terminated NCT04089709 - Well-arm Exercise in Distal Radius Fractures N/A
Completed NCT05623865 - The Effect of Kinesio Taping on Edema Control and Wrist Functions in Conservatively Followed Distal Radius Fractures. N/A