Clinical Trials Logo

Clinical Trial Summary

OBJECTIVE: This study aimed to determine the sensitivity and specificity of various anatomic measurements alone or in combination in predicting difficult intubation. The investigators hypothesized that goniomastoid distance, thyrogonial distance and tongue movements are sensitive and specific tests for predicting difficult intubation MATERIALS AND METHODS: The investigators included the data of 170 patients (85 difficult intubation and 85 easy intubation) who underwent an abdominal surgery under general anesthesia. Patients in difficult intubation (n=85) and easy intubation (n=85) groups were matched by age, BMI, and gender. Intubation difficulty scale (IDS) scores were recorded. Upward and downward maximal protrusions of tongue (UMPT and DMPT, respectively) were evaluated in all patients. Anthropometric measurements were measured.


Clinical Trial Description

To define the tongue protrusion tests, anatomic landmarks and horizontal lines were used. The first horizontal line (lower target line) was passing through the midpoint of the distance between stomion to mentum (mandible height) and the second horizontal line (upper target line) was passing through the midpoint of the distance from subnasal to stomion (upper lip height). The horizontal lines were drawn with an erasable marker pen on the each patient's face. In the sitting position, patients were asked to make maximal tongue protrusion upward (UMPT) and downward (DMPT) in anatomical neutral position. The inability of the tip of the tongue to reach to the target line was scored "1" and ability of the tongue tip to reach or pass the target line was scored "2 ;


Study Design

Allocation: Randomized, Intervention Model: Parallel Assignment, Masking: Double Blind (Subject, Investigator), Primary Purpose: Diagnostic


Related Conditions & MeSH terms


NCT number NCT02814266
Study type Interventional
Source Trakya University
Contact
Status Completed
Phase N/A
Start date November 2015
Completion date June 2016

See also
  Status Clinical Trial Phase
Completed NCT03657927 - A Comparison of McGrath MAC Versus C-MAC Videolaryngoscopes in Morbidly Obese Patients N/A
Enrolling by invitation NCT04506346 - Risk Prediction of Difficult Tracheal Intubation in OSAHS Patient
Completed NCT02944305 - A Predictive Model for Difficult Intubation N/A
Completed NCT02476565 - Comparison of Endotracheal Intubation Over the Aintree Via the I-gel and Laryngeal Mask Airway Supreme N/A
Completed NCT02823392 - Difficult Bag Mask Ventilation and Difficult Intubation in Children
Completed NCT05347680 - A Comparison Between the Intubating Laryngeal Tube Suction and the Ambu AuraGain N/A
Completed NCT03265938 - Evaluation of Video Laryngoscopy in Patients With Head and Neck Pathology
Completed NCT05545982 - Comparison of Video Laryngoscope Using Miller or Macintosh Approach During Endotracheal Intubation N/A
Completed NCT03320278 - The Evaluation of Simplified Predictive Intubation Difficulty Score.
Completed NCT01532063 - Risk Factors of Difficult Intubation and Related Complications in Adults in Intensive Care Units: FRIDA-Rea N/A
Completed NCT03709524 - Orotracheal Intubation in Adult Patients: A Comparison of Standard Airtraq , Nasotracheal Airtraq Combined With a Stylet Inserted Endotracheal Tube and Standard Airtraq Combined Fiberoptic Intubation N/A
Recruiting NCT03902704 - Safety and Efficacy of Cleverscope. A New Medical Device for Tracheal Intubation N/A
Not yet recruiting NCT05607433 - Air Q Laryngeal Airway Versus the AmbuAura Gain as a Conduit for Endotracheal Intubation N/A
Active, not recruiting NCT04759287 - Effectiveness of C-MAC Video-stylet Versus Fiberoptic Bronchoscope for Awake Intubation N/A
Completed NCT03547193 - Two Neck Ultrasound Measurements as Predictors of Difficult Laryngoscopy
Completed NCT04822831 - The Effect of Semi-recumbent Position With Exercise Training on Long-term Ventilator-dependent Patients N/A
Completed NCT03165461 - Evaluation of the Use of Tracheal Intubation Through a Laryngeal Tube to Intubate Anesthetized Patients
Recruiting NCT02177240 - A Comparison of the Flex-it® to the GlideRite® Stylet for GlideScope® in Simulated Difficult Intubations. N/A
Recruiting NCT01612949 - Facial Analysis to Classify Difficult Intubation
Completed NCT04168840 - Ultrasound Parameters to Predict Difficult Airway