Clinical Trials Logo

Clinical Trial Summary

A. Pain and other disadvantages of AV fistula cannulation can be limited by using the so-called buttonhole technique.

B. Till present in our center catheters with cylindrical points are used for cannulation of AV fistulas with the rope ladder technique. One can hypothesize that a catheter with a bevel point might have some advantages such as a larger entrance area and less traumatic cannulation. The latter may influence pain sensation of the patients.

The above background information gives rise to the following investigational questions:

A. Buttonhole vs rope ladder technique

1. Is pain sensation different when using buttonhole cannulation as compared to rope ladder cannulation technique?

Hypothesis:

AV fistula cannulation by buttonhole technique causes less pain than cannulation by rope ladder technique.

2. Is the level of anxiety different when using buttonhole cannulation as compared to rope ladder cannulation technique?

Hypothesis:

AV fistula cannulation by buttonhole technique causes less anxiety than cannulation by rope ladder technique.

3. Is bleeding time different when using buttonhole cannulation as compared to rope ladder cannulation technique?

Hypothesis:

Bleeding time is shorter when using buttonhole technique versus rope ladder technique.

4. Is the number and severity of complications related to AV fistula cannulation different between buttonhole and rope ladder technique?

Hypothesis:

When using the buttonhole technique for AV fistula cannulation the number and severity of complications is less than when using the rope ladder technique.

B. Rope ladder technique using catheters with cylindrical vs. bevel point

5. Is pain sensation different when using rope ladder cannulation catheters with cylindrical as compared to bevel point?

Hypothesis:

AV fistula cannulation using bevel point catheters causes less pain than cannulation using cylindrical point catheters.


Clinical Trial Description

A. Pain and other disadvantages of AV fistula cannulation can be limited by using the so-called buttonhole technique. It was described for the first time as the "contant site method" by Twardowski et al. The authors report on a patient in whom the fistula was too short to use the rope ladder technique. As an alternative, the access was cannulated at a "constant site". Later, in 1984, Krönung used the name "buttonhole puncture technique". It was used primarily in patients treated with home hemodialysis, where cannulation was performed by one single person (often by the patient himself). In order to form a perfect buttonhole it is indeed essential that the fistula is cannulated at exactly the same site and using exactly the same angle every single time. The buttonhole technique has been adopted by the recent "National Kidney Foundation Kidney Disease Outcomes Quality Initiative (NKF K/DOQI) Guidelines" for vascular access. Studies show that patient pain scores and bleeding time after dialysis are positively influenced when using this cannulation technique.

B. Till present in our center catheters with cylindrical points are used for cannulation of AV fistulas with the rope ladder technique. One can hypothesize that a catheter with a bevel point might have some advantages such as a larger entrance area and less traumatic cannulation. The latter may influence pain sensation of the patients.

The above background information gives rise to the following investigational questions:

A. Buttonhole vs rope ladder technique

1. Is pain sensation different when using buttonhole cannulation as compared to rope ladder cannulation technique?

Hypothesis:

AV fistula cannulation by buttonhole technique causes less pain than cannulation by rope ladder technique.

2. Is the level of anxiety different when using buttonhole cannulation as compared to rope ladder cannulation technique?

Hypothesis:

AV fistula cannulation by buttonhole technique causes less anxiety than cannulation by rope ladder technique.

3. Is bleeding time different when using buttonhole cannulation as compared to rope ladder cannulation technique?

Hypothesis:

Bleeding time is shorter when using buttonhole technique versus rope ladder technique.

4. Is the number and severity of complications related to AV fistula cannulation different between buttonhole and rope ladder technique?

Hypothesis:

When using the buttonhole technique for AV fistula cannulation the number and severity of complications is less than when using the rope ladder technique.

B. Ropeladder technique using catheters with cylindrical vs. bevel point

5. Is pain sensation different when using rope ladder cannulation catheters with cylindrical as compared to bevel point?

Hypothesis:

AV fistula cannulation using bevel point catheters causes less pain than cannulation using cylindrical point catheters. ;


Study Design

Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT00544492
Study type Interventional
Source Universitaire Ziekenhuizen Leuven
Contact
Status Completed
Phase Phase 4
Start date October 2007
Completion date March 2010

See also
  Status Clinical Trial Phase
Not yet recruiting NCT05031013 - Trace Elements Concentration in Dialysis
Not yet recruiting NCT03090828 - Economic Evaluation of an Education Platform for Patients With End-stage Renal Disease N/A
Completed NCT01685372 - Immunogenicity of Fluzone High Dose in Immunocompromised Children and Young Adults Phase 2
Active, not recruiting NCT01394770 - Aliskiren or Amlodipine in Hypertensive Hemodialysed Patients Phase 4
Completed NCT00537979 - Efficacy and Safety of 6 Months Treatment With Paricalcitol Injection or Oral in Patients With Secondary Hyperparathyroidism on Dialysis Phase 4
Completed NCT00506441 - A Phase 3, Randomized, Double Blind, Placebo-Controlled, Multi-Center, Withdrawal Study of MCI-196 in CKD on Dialysis With Hyperphosphatemia Phase 3
Completed NCT05415969 - CKD-aP Among Adults on Dialysis in Switzerland
Recruiting NCT04024007 - Determination of Citrate Clearance Used in Regional Anticoagulation of Continuous Venous Hemofiltration Circuits
Completed NCT03772171 - Estimate for Dietary Intakes and Hemodialysis Patients
Recruiting NCT02586402 - Safety & Efficacy of Pegolsihematide for Treatment of Anemia in Participants on Dialysis Phase 2
Active, not recruiting NCT01693263 - Outcome of BCF Access in Hemodialysis Patients
Completed NCT01421771 - Blood Pressure in Dialysis Patients N/A
Active, not recruiting NCT01065389 - Resistance Training in Intradialysis Patients Phase 2
Completed NCT03910426 - Prognostic Determinants of Survival and Quality of Life in Prevalent End-stage Kidney Disease Patients
Completed NCT04667741 - Post-dialysis Recovery Time and Affecting Factors Between Turkey and Portugal
Completed NCT04565522 - Transmission of COVID-19 Virus Among Patients and Staff in Dialysis Centers
Completed NCT04655989 - A Study to Demonstrate the Safety and Effectiveness of the NIKKISO DBB-EXA ES Hemodialysis Delivery System N/A
Completed NCT05125848 - Clinical Evaluation of the CM-1500 During Hemodialysis N/A
Completed NCT04633915 - Antibody Response in Hemodialysis and Non-dialysis Patients Diagnosed With COVID-19.
Active, not recruiting NCT00767897 - The Impact of the Human Papilloma Virus in Pediatric Chronic Kidney Disease, Dialysis, and Transplant Patients