Dental Prosthesis Failure Clinical Trial
Official title:
Digital Technique to Analyze the Wear of Screw-Retained Implant-Supported Metal-Ceramic Dental Prostheses and Natural Tooth as Antagonist. A Pilot Study
Verified date | May 2023 |
Source | University of Salamanca |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
The aim of this study was to describe a novel digital technique to analyze the wear of screw-retained implant-supported metal-ceramic dental prostheses and natural tooth as antagonist. Materials and methods: Ten patients were consecutively included to rehabilitate partial edentulism by dental implants. Both the screw-retained implant-supported metal-ceramic dental prostheses and the natural tooth as antagonist were submitted to a digital impression through an intraoral scan to generate a Standard Tessellation Language digital file preoperatively (STL1), at 3 months (STL2), and 6 months (STL3) follow-up. Afterwards, an alignment procedure of the digital files (STL1-STL3) was performed on a reverse engineering morphometric software and volume changes at the screw-retained implant-supported metal-ceramic dental prostheses and the natural tooth as antagonist were analyzed using Student's t-test. Moreover, Gage R&R statistical analysis was conducted to analyze the repeatability and reproducibility of the digital technique.
Status | Completed |
Enrollment | 10 |
Est. completion date | September 1, 2022 |
Est. primary completion date | March 1, 2022 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 21 Years to 35 Years |
Eligibility | Inclusion Criteria: - in good health, who presented partial edentulism in the posterior upper maxilla, were consecutively included to rehabilitate partial edentulism by dental implants Exclusion Criteria: - all those who do not meet the inclusion criteria |
Country | Name | City | State |
---|---|---|---|
Spain | University of Salamanca | Salamanca |
Lead Sponsor | Collaborator |
---|---|
University of Salamanca |
Spain,
Castellanos-Cosano L, Rodriguez-Perez A, Spinato S, Wainwright M, Machuca-Portillo G, Serrera-Figallo MA, Torres-Lagares D. Descriptive retrospective study analyzing relevant factors related to dental implant failure. Med Oral Patol Oral Cir Bucal. 2019 N — View Citation
Etman MK, Woolford M, Dunne S. Quantitative measurement of tooth and ceramic wear: in vivo study. Int J Prosthodont. 2008 May-Jun;21(3):245-52. Erratum In: Int J Prosthodont. 2008 Nov-Dec;21(6):508. — View Citation
Fisher RM, Moore BK, Swartz ML, Dykema RW. The effects of enamel wear on the metal-porcelain interface. J Prosthet Dent. 1983 Nov;50(5):627-31. doi: 10.1016/0022-3913(83)90198-1. — View Citation
Heintze SD, Zellweger G, Sbicego S, Rousson V, Munoz-Viveros C, Stober T. Wear of two denture teeth materials in vivo-2-year results. Dent Mater. 2013 Sep;29(9):e191-204. doi: 10.1016/j.dental.2013.04.012. Epub 2013 Jun 6. — View Citation
Hmaidouch R, Weigl P. Tooth wear against ceramic crowns in posterior region: a systematic literature review. Int J Oral Sci. 2013 Dec;5(4):183-90. doi: 10.1038/ijos.2013.73. Epub 2013 Oct 18. — View Citation
Hudson JD, Goldstein GR, Georgescu M. Enamel wear caused by three different restorative materials. J Prosthet Dent. 1995 Dec;74(6):647-54. doi: 10.1016/s0022-3913(05)80319-1. — View Citation
Oh WS, Delong R, Anusavice KJ. Factors affecting enamel and ceramic wear: a literature review. J Prosthet Dent. 2002 Apr;87(4):451-9. doi: 10.1067/mpr.2002.123851. — View Citation
Ohlmann B, Trame JP, Dreyhaupt J, Gabbert O, Koob A, Rammelsberg P. Wear of posterior metal-free polymer crowns after 2 years. J Oral Rehabil. 2008 Oct;35(10):782-8. doi: 10.1111/j.1365-2842.2008.01865.x. Epub 2008 May 9. — View Citation
Seghi RR, Rosenstiel SF, Bauer P. Abrasion of human enamel by different dental ceramics in vitro. J Dent Res. 1991 Mar;70(3):221-5. doi: 10.1177/00220345910700031301. — View Citation
Stober T, Geiger A, Rues S, Dreyhaupt J, Rammelsberg P, Ohlmann B. Factors affecting wear of composite resin denture teeth--24-month results from a clinical study. Clin Oral Investig. 2012 Apr;16(2):413-20. doi: 10.1007/s00784-011-0534-y. Epub 2011 Mar 8. — View Citation
Wiley MG. Effects of porcelain on occluding surfaces of restored teeth. J Prosthet Dent. 1989 Feb;61(2):133-7. doi: 10.1016/0022-3913(89)90360-0. — View Citation
Yilmaz H, Aydin C, Gul BE. Flexural strength and fracture toughness of dental core ceramics. J Prosthet Dent. 2007 Aug;98(2):120-8. doi: 10.1016/S0022-3913(07)60045-6. — View Citation
Zubizarreta-Macho A, Triduo M, Alonso Perez-Barquero J, Guinot Barona C, Albaladejo Martinez A. Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: An In Vitr — View Citation
* Note: There are 13 references in all — Click here to view all references
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Wear volume (µm3) of the screw-retained implant-supported metal-ceramic dental prostheses | Wear volume (µm3) of the screw-retained implant-supported metal-ceramic dental prostheses at 3 months follow-up appointment | 3 months follow-up appointment | |
Primary | Wear volume (µm3) of the screw-retained implant-supported metal-ceramic dental prostheses | Wear volume (µm3) of the screw-retained implant-supported metal-ceramic dental prostheses at 6 months follow-up appointment | 6 months follow-up appointment | |
Primary | Wear volume (µm3) of the natural tooth as antagonist | Wear volume (µm3) of the natural tooth as antagonist at 3 months follow-up appointment | 3 months follow-up appointment | |
Primary | Wear volume (µm3) of the natural tooth as antagonist | Wear volume (µm3) of the natural tooth as antagonist at 6 months follow-up appointment | 6 months follow-up appointment |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04045574 -
DAMP1: The 1T1T Concept Versus Conventional Implant Loading Protocol
|
N/A | |
Recruiting |
NCT05296291 -
RCT: Titanium vs FCZ vs Zirconia Framework
|
N/A | |
Active, not recruiting |
NCT05752539 -
Clinical Evaluation of Implants Restored With Advanced Lithium Disilicate Screw-retained Crowns
|
||
Active, not recruiting |
NCT05599269 -
Retrospective Clinical Evaluation of Nano-hybrid-composite Denture Teeth
|
N/A | |
Not yet recruiting |
NCT04151316 -
Study of Periodontal Tissues in Fixed Prostheses on Natural Teeth
|
N/A | |
Completed |
NCT03720236 -
Peri-implant Tissues in BLX® Implants
|
N/A | |
Completed |
NCT04304222 -
Application of 3D Printed Removable Denture Prosthesis Framework for Partial Edentulous Patients
|
N/A | |
Recruiting |
NCT05958043 -
Performance of CAD/CAM Milled and 3D-printed Full-arch Implant-supported Provisionals Restorations
|
N/A | |
Completed |
NCT03796494 -
Peri-implant Tissues on Aesthetic Slim Abutment Galimplant (PSG)
|
N/A | |
Recruiting |
NCT02898311 -
One-Tooth One-Time (1T1T) A Straightforward Approach to Replace Missing Teeth in the Posterior Region: a Case Series
|
N/A | |
Completed |
NCT01449903 -
Survival of Different Core Build-up Materials
|
||
Completed |
NCT04870658 -
Patient's Perception of Complications in Implantology.
|
||
Completed |
NCT03640910 -
Attachment Systems for Implant Overdenture
|
N/A | |
Completed |
NCT04272112 -
Clinical Performance of All-ceramic Posterior Crowns. A Randomized, Prospective Clinical.
|
N/A | |
Active, not recruiting |
NCT01729858 -
Survival of Implant-Supported All-Ceramic Prostheses
|
||
Recruiting |
NCT05818436 -
Immediate Dental Prosthesis Functionalization Protocol in People Over 70 Years of Age
|
N/A |