Dental Implants Clinical Trial
Official title:
Biting Force and Quality of Life in Porcelain-fused-to Metal Versus Zirconia Implant- Supported in Mandibular Kennedy Class II ( In Vivo Study )
The goal of this randomized clinical trial is to compare biting force and patient satisfaction in three groups. Patients in the control group number one will receive a CoCr removable partial denture, and in the other two groups, implants will be inserted to restore missed posterior teeth (second mandibular premolar and second mandibular molar) in the span area. After three months, implants will be loaded with three units of anatomical PFM-fixed partial dentures in group number two, while in group number three, implants will be loaded with three units of anatomical Zirconia-fixed partial dentures. Biting force will be measured bilaterally at the time of delivery of the removable partial denture and delivery of fixed partial dentures after two, four, and six months. Patient satisfaction will be assessed through a quality-of life questionnaire at the six-months recall appointment
Thirty-three partially edentulous patients will be recruited. Patients will be randomly divided into three groups. Patients in the control group number one will receive a CoCr removable partial denture; in the other two groups, implants will be inserted to restore missed posterior teeth (second mandibular premolar and second mandibular molar) in the span area using a two-stage surgical technique with the help of a radiographic and surgical stent. Pre-surgical and post-surgical prescription of antibiotics, anti-inflammatory drugs, analgesic drugs, and mouthwash for one week, then a follow-up will be done at the suture removal appointment. After a three-month osseointegration period, implants will be loaded with three units of anatomical PFM-fixed partial dentures in group number two, while in group number three, implants will be loaded with three units of anatomical Zirconia-fixed partial dentures. Recall appointments will be scheduled for the patients two, four, and six months after loading for the collection of the data. Biting force will be measured using a biting force sensor for both the intact and restored sides at the time of delivery of the removable partial denture and at the loading of implants after two, four, and six months. Patient satisfaction will be assessed through a quality-of-life questionnaire at the six-months recall appointment. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05466006 -
Peri-implant Soft Tissue Volume Changes at Small Buccal Dehiscences
|
N/A | |
Withdrawn |
NCT00313989 -
Evaluation of Osseo-integration After Placement of Dental Implants With Patients Receiving Radiotherapy for Buccopharyngeal Oncology
|
N/A | |
Completed |
NCT05081050 -
Short Implants Supporting Single Crowns in the Posterior Region
|
||
Completed |
NCT04707677 -
Comparative Aesthetic Analysis Between Titanium and Ceramic Implants
|
N/A | |
Recruiting |
NCT05989061 -
PEEK Versus Titanium Customized Healing Abutments
|
N/A | |
Recruiting |
NCT05722041 -
Soft Tissue Volume Changes in Posterior Socket Sealing Abutment.
|
||
Completed |
NCT05512845 -
The Double Factor Technique: a Computer-guided Implant Surgery Technique for Fully Edentulous Patients
|
||
Recruiting |
NCT03837158 -
Titanium Zirconium (TiZr) Mini Implants
|
N/A | |
Completed |
NCT01944267 -
Procedures for Improving the Mucosa Around Implants
|
N/A | |
Completed |
NCT00971516 -
Healing Profile of Titanium Dental Implants Placed in Patients With Diabetes
|
N/A | |
Completed |
NCT04305080 -
Effect of Anodic Oxidation of Implant Abutment Collar on the Peri-implant Soft Tissue Health
|
N/A | |
Completed |
NCT06191510 -
Xenogenic Bone Intentionally Left Exposed
|
||
Completed |
NCT04459494 -
In the Treatment of Implants With Different Methods; Early Bone Loss and Patient Satisfaction
|
N/A | |
Recruiting |
NCT05644470 -
Association of Implant Position and Crown Contour With Tissue Health
|
||
Completed |
NCT05101954 -
Platelet Rich Fibrin and Concentrated Growth Factors on Osseointegration of Immediate Implants
|
N/A | |
Recruiting |
NCT05748379 -
Atraumatic Zirconia Abutment Versus Customized Composite Healing Abutment in Maxilla or Mandible.
|
N/A | |
Recruiting |
NCT05627037 -
Marginal Bone Level Around Titanium Implants Produced by Additive Manufacture
|
N/A | |
Enrolling by invitation |
NCT06187805 -
Retrospective Case Series - OSSIX Volumax Collagen Xenograft Scaffolding
|
||
Recruiting |
NCT06100120 -
A Triple-blinded Non-inferiority Multicentre Randomized Controlled Trial Comparing Hybrid and Fully Etched Implants P1
|
N/A | |
Recruiting |
NCT06155799 -
Accuracy of Dynamic Navigation System on Zygomatic Implant Placement
|
N/A |