Dental Implantation Clinical Trial
Official title:
Comparison of Positional Accuracy in Dental Implant Placement Between Conventionally Used Guide Pin and 3D Printed Surgical Guide Developed From CBCT
This is a randomized controlled study that aims to compare the accuracy between full-guided with guide-pin-assisted free-hand dental implant surgeries. The basis of evaluation in each case is the comparison of the preoperative digital plan with the actual postoperative status.
Status | Recruiting |
Enrollment | 28 |
Est. completion date | July 31, 2024 |
Est. primary completion date | April 30, 2024 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 18 Years to 75 Years |
Eligibility | Inclusion Criteria: - Patients of age between 18 to 75 and of any gender - Patient fit for implantation (satisfactory soft and hard tissue conditions and occlusion) - Partially edentulous patient Exclusion Criteria: - Patient with pregnancy - Patient with uncontrolled diabetes mellitus. - Patient who needed dentoalveolar or associated soft tissue reconstruction procedure - Patient taking bisphosphonate or have any history of systemic or local bone disease - Recent extracted sites - Patients with a history of smoking, alcoholism - Patient with a history of head-neck radiation - Patient with associated periapical pathology or history of parafunctional habit - Patient needs bone grafting. - Known HIV, Hepatitis B, or Hepatitis C infection. - Limited mouth opening, which, in the examiner's opinion, would risk the success of the intervention - Local infection - Known allergy to any component of the implant or the implant guide |
Country | Name | City | State |
---|---|---|---|
Bangladesh | Dhaka Dental College and Hospital | Dhaka |
Lead Sponsor | Collaborator |
---|---|
Dhaka Dental College and Hospital | Bangladesh University of Engineering and Technology |
Bangladesh,
Albrektsson T, Dahl E, Enbom L, Engevall S, Engquist B, Eriksson AR, Feldmann G, Freiberg N, Glantz PO, Kjellman O, et al. Osseointegrated oral implants. A Swedish multicenter study of 8139 consecutively inserted Nobelpharma implants. J Periodontol. 1988 May;59(5):287-96. doi: 10.1902/jop.1988.59.5.287. — View Citation
Bacchetti P, Leung JM. Sample size calculations in clinical research. Anesthesiology. 2002 Oct;97(4):1028-9; author reply 1029-32. doi: 10.1097/00000542-200210000-00050. No abstract available. — View Citation
Cassetta M, Stefanelli LV, Giansanti M, Di Mambro A, Calasso S. Depth deviation and occurrence of early surgical complications or unexpected events using a single stereolithographic surgi-guide. Int J Oral Maxillofac Surg. 2011 Dec;40(12):1377-87. doi: 10.1016/j.ijom.2011.09.009. Epub 2011 Oct 15. — View Citation
Coravos A, Goldsack JC, Karlin DR, Nebeker C, Perakslis E, Zimmerman N, Erb MK. Digital Medicine: A Primer on Measurement. Digit Biomark. 2019 May 9;3(2):31-71. doi: 10.1159/000500413. eCollection 2019 May-Aug. — View Citation
D'haese J, Van De Velde T, Komiyama A, Hultin M, De Bruyn H. Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature. Clin Implant Dent Relat Res. 2012 Jun;14(3):321-35. doi: 10.1111/j.1708-8208.2010.00275.x. Epub 2010 May 11. — View Citation
Geng W, Liu C, Su Y, Li J, Zhou Y. Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement. Int J Clin Exp Med. 2015 Jun 15;8(6):8442-9. eCollection 2015. — View Citation
Israelson H, Plemons JM, Watkins P, Sory C. Barium-coated surgical stents and computer-assisted tomography in the preoperative assessment of dental implant patients. Int J Periodontics Restorative Dent. 1992;12(1):52-61. — View Citation
Jacobs R, Adriansens A, Naert I, Quirynen M, Hermans R, Van Steenberghe D. Predictability of reformatted computed tomography for pre-operative planning of endosseous implants. Dentomaxillofac Radiol. 1999 Jan;28(1):37-41. doi: 10.1038/sj.dmfr.4600403. — View Citation
Jacobs R, Adriansens A, Verstreken K, Suetens P, van Steenberghe D. Predictability of a three-dimensional planning system for oral implant surgery. Dentomaxillofac Radiol. 1999 Mar;28(2):105-11. doi: 10.1038/sj/dmfr/4600419. — View Citation
Kernen F, Benic GI, Payer M, Schar A, Muller-Gerbl M, Filippi A, Kuhl S. Accuracy of Three-Dimensional Printed Templates for Guided Implant Placement Based on Matching a Surface Scan with CBCT. Clin Implant Dent Relat Res. 2016 Aug;18(4):762-8. doi: 10.1111/cid.12348. Epub 2015 Apr 28. — View Citation
Kiatkroekkrai P, Takolpuckdee C, Subbalekha K, Mattheos N, Pimkhaokham A. Accuracy of implant position when placed using static computer-assisted implant surgical guides manufactured with two different optical scanning techniques: a randomized clinical trial. Int J Oral Maxillofac Surg. 2020 Mar;49(3):377-383. doi: 10.1016/j.ijom.2019.08.019. Epub 2019 Sep 20. — View Citation
Lin CC, Ishikawa M, Maida T, Cheng HC, Ou KL, Nezu T, Endo K. Stereolithographic Surgical Guide with a Combination of Tooth and Bone Support: Accuracy of Guided Implant Surgery in Distal Extension Situation. J Clin Med. 2020 Mar 5;9(3):709. doi: 10.3390/jcm9030709. — View Citation
Schneider D, Marquardt P, Zwahlen M, Jung RE. A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry. Clin Oral Implants Res. 2009 Sep;20 Suppl 4:73-86. doi: 10.1111/j.1600-0501.2009.01788.x. — View Citation
Verstreken K, Van Cleynenbreugel J, Martens K, Marchal G, van Steenberghe D, Suetens P. An image-guided planning system for endosseous oral implants. IEEE Trans Med Imaging. 1998 Oct;17(5):842-52. doi: 10.1109/42.736056. — View Citation
Wang X, Ji X. Sample Size Estimation in Clinical Research: From Randomized Controlled Trials to Observational Studies. Chest. 2020 Jul;158(1S):S12-S20. doi: 10.1016/j.chest.2020.03.010. — View Citation
Younes F, Cosyn J, De Bruyckere T, Cleymaet R, Bouckaert E, Eghbali A. A randomized controlled study on the accuracy of free-handed, pilot-drill guided and fully guided implant surgery in partially edentulous patients. J Clin Periodontol. 2018 Jun;45(6):721-732. doi: 10.1111/jcpe.12897. Epub 2018 May 10. — View Citation
* Note: There are 16 references in all — Click here to view all references
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Angular deviation | The angle formed by the primary axis of the proposed digital implant and the actual implant as put, stated in degrees. | 3 months | |
Secondary | Apical deviation | The deviation of the implant's apical point from the anticipated apical position in three dimensions, measured in millimeters. | 3 months | |
Secondary | Coronal deviation | The deviation of the implant's coronal point from the anticipated coronal position in three dimensions, measured in millimeters. | 3 months |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04945629 -
Plasma Rich in Growth Factors in the Preservation of the Alveolar Ridge After Simple Molar Tooth Extractions.
|
Phase 3 | |
Recruiting |
NCT05758337 -
Vibropneumostimulation in the Rehabilitation After Dental Implantation
|
N/A | |
Recruiting |
NCT05741749 -
Immediate Implant Placement in the Posterior Region Combining Sealing Socket Abutment and Peri-implant Socket Filling.
|
N/A | |
Recruiting |
NCT04093583 -
Randomized Clinical Trial, Conventional Treatment-controlled, Studying the Efficacy of Plasma Rich in Growth Factor (PRGF®) in Alveolar Ridge Preservation After Simple Exodontia in the Anterior Region of Maxilla.
|
Phase 3 | |
Not yet recruiting |
NCT03321162 -
Accuracy of Guided Implant Placement Using Double Versus Triple Scan Protocol in Completely Edentulous Patients
|
N/A | |
Completed |
NCT00066014 -
Clinical Investigation of Mandibular Implant Overdenture
|
Phase 2 | |
Completed |
NCT05843526 -
Influence of Implant Component Materials on Peri-implant Soft Tissue Horst Response.
|
N/A | |
Completed |
NCT06323993 -
The Effect of Different Window-preparation Approaches on the Clinical Outcomes of Lateral Sinus Floor Elevation
|
||
Not yet recruiting |
NCT06044246 -
Influence of Human Platelet Derivatives on Dental Implant
|
N/A | |
Not yet recruiting |
NCT03164759 -
Correlation Between Radiographic Bone Density in CBCT and Implant Stability Quotient Value: Clinical Observational Study
|
N/A | |
Completed |
NCT04950491 -
Patient-reported Outcome Measures Comparing Static Computer-aided Implant Surgery and Conventional Implant Surgery
|
N/A | |
Recruiting |
NCT05938868 -
Low Intensity Pulsed Ultrasound Versus Low Level Laser Therapy Post Dental Implant
|
N/A | |
Not yet recruiting |
NCT00519571 -
Evaluation of the Safety and Efficacy of Using ImplantLock Device - Dental Implant Accessory
|
N/A | |
Recruiting |
NCT05817526 -
BMAC Loaded Collagen Jumping the Gap Around Immediate Implants
|
N/A | |
Completed |
NCT03222219 -
Implant Insertion Torque and Primary Stability
|
||
Completed |
NCT04346706 -
Immediate Implant Placement in Fresh Extraction Sockets and Delayed Implants in Healed Sockets.
|
N/A | |
Recruiting |
NCT05105113 -
Evaluation of Survival and Success Rates of Zirzonia Dental Implants
|
N/A | |
Withdrawn |
NCT01154868 -
Clinical and Histological Evaluation of Healos® for Alveolar Ridge Augmentation
|
Phase 4 | |
Completed |
NCT03915509 -
Evaluation Of The Effect Of Surface Properties On The Stabılıty Of The Different Implants
|
N/A | |
Completed |
NCT06176287 -
Assessment of Pain Associated With Insertion Torque and Correlation of Primary Implant Stability Measurement Methods
|
N/A |