Clinical Trials Logo

Clinical Trial Summary

A new comprehensive technique of dental implantation and rehabilitation of patients will be developed and theoretically justified, including an individual dental implant of a dowel system made of non-woven titanium material with through porosity and vibropneumostimulation, which will improve the functional and anatomical results of treatment. In the complex treatment and rehabilitation of patients after dental implantation, a vibropneumostimulator with vibratodes of its own design will be used, which activate bone remodeling, which will expand the practical application and theoretical knowledge in the field of hardware massage.


Clinical Trial Description

The aim of the study: to improve the results of treatment of patients after dental implantation by using vibropneumostimulation of periimplant tissues. In the work, a complex of functional and clinical methods (thermography, radiography, periotestometry) will be used. The following methods will also be used: - echosteometry, thanks to which the density of bone tissue in the periimplant zone will be studied, which will allow to study the processes of bone tissue remodulation. - radioisotope diagnostics, thanks to which the dynamics of bone metabolism processes around implants will be studied, which will expand the knowledge of the metabolism of jaw bones. The subject of the study is the remodulation of bone tissue around the implant, which will allow us to develop a new concept of the relationship of processes in the bone tissue around implants of various designs. The study is based on the study and generalization of existing scientific data on surgical treatment of patients, as well as on the assessment of the relevance and degree of development of the topic. To improve the quality of care for patients after implantation, in our research we will use vibro-pneumatic action on the tissues of the upper and lower jaws in the field of implantation by a device of the SamSMU design - a medical vibro-pneumatic stimulator, it will be an automated system for pneumatic wave massage and vibration exposure. A vibropneumostimulator with vibratodes of its own design will be introduced into clinical practice, which will expand the arsenal of hardware treatment of an implantologist. In the complex treatment of patients with partial and complete loss of teeth, an improved dental implant of a dowel system made of non-woven titanium material with through porosity will be offered for using. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05758337
Study type Interventional
Source Samara State Medical University
Contact Ivan Bayrikov, MD
Phone +79061274992
Email i.m.bajrikov@samsmu.ru
Status Recruiting
Phase N/A
Start date September 1, 2022
Completion date September 1, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT04945629 - Plasma Rich in Growth Factors in the Preservation of the Alveolar Ridge After Simple Molar Tooth Extractions. Phase 3
Recruiting NCT05741749 - Immediate Implant Placement in the Posterior Region Combining Sealing Socket Abutment and Peri-implant Socket Filling. N/A
Recruiting NCT04093583 - Randomized Clinical Trial, Conventional Treatment-controlled, Studying the Efficacy of Plasma Rich in Growth Factor (PRGF®) in Alveolar Ridge Preservation After Simple Exodontia in the Anterior Region of Maxilla. Phase 3
Not yet recruiting NCT03321162 - Accuracy of Guided Implant Placement Using Double Versus Triple Scan Protocol in Completely Edentulous Patients N/A
Completed NCT00066014 - Clinical Investigation of Mandibular Implant Overdenture Phase 2
Completed NCT05843526 - Influence of Implant Component Materials on Peri-implant Soft Tissue Horst Response. N/A
Completed NCT06323993 - The Effect of Different Window-preparation Approaches on the Clinical Outcomes of Lateral Sinus Floor Elevation
Not yet recruiting NCT06044246 - Influence of Human Platelet Derivatives on Dental Implant N/A
Not yet recruiting NCT03164759 - Correlation Between Radiographic Bone Density in CBCT and Implant Stability Quotient Value: Clinical Observational Study N/A
Completed NCT04950491 - Patient-reported Outcome Measures Comparing Static Computer-aided Implant Surgery and Conventional Implant Surgery N/A
Recruiting NCT05938868 - Low Intensity Pulsed Ultrasound Versus Low Level Laser Therapy Post Dental Implant N/A
Not yet recruiting NCT00519571 - Evaluation of the Safety and Efficacy of Using ImplantLock Device - Dental Implant Accessory N/A
Recruiting NCT05817526 - BMAC Loaded Collagen Jumping the Gap Around Immediate Implants N/A
Completed NCT03222219 - Implant Insertion Torque and Primary Stability
Completed NCT04346706 - Immediate Implant Placement in Fresh Extraction Sockets and Delayed Implants in Healed Sockets. N/A
Recruiting NCT05105113 - Evaluation of Survival and Success Rates of Zirzonia Dental Implants N/A
Recruiting NCT05983718 - A Study of Surgical Guide Assisted Dental Implantation in Bangladesh N/A
Withdrawn NCT01154868 - Clinical and Histological Evaluation of Healos® for Alveolar Ridge Augmentation Phase 4
Completed NCT03915509 - Evaluation Of The Effect Of Surface Properties On The Stabılıty Of The Different Implants N/A
Completed NCT06176287 - Assessment of Pain Associated With Insertion Torque and Correlation of Primary Implant Stability Measurement Methods N/A