Dental Implantation Clinical Trial
Official title:
Accuracy of Guided Implant Placement Using Double Versus Triple Scan Protocol in Completely Edentulous Patients : Randomized Clinical Trial
16 implant placement by surgical guide using double scan protocol versus triple scan protocol to Evaluate angular and linear deviation of virtual implants and actual implant position in completely edentulous patients according to scanning protocol C1(double scan technique) and C2 (triple scan technique) .
In this study we discuss linear and angular deviation of actual implant position using
planning protocol C1(double scan technique) or C2 (triple scan technique) in completely
edentulous patient .
Both protocols C1(double scan technique) and C2 (triple scan technique) indicated in
completely edentulous patient and require C.T scan for patient wearing scan appliance .
In C1(double scan technique) , after CT scan for patient wearing scan appliance , two optical
scan for the model with and without scan appliance.
In C2 (triple scan technique) , after CT scan for patient wearing scan appliance , CT scan
for scan appliance alone .
Teeth positions in both protocols were identified by radio-opaque scan appliance .
16 implant placement by surgical guide using double scan protocol versus triple scan protocol
( two groups - 8 implants in each group ) to Evaluate angular and linear deviation of virtual
implants and actual implant position in completely edentulous patients according to scanning
protocol C1(double scan technique) and C2 (triple scan technique) .
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04945629 -
Plasma Rich in Growth Factors in the Preservation of the Alveolar Ridge After Simple Molar Tooth Extractions.
|
Phase 3 | |
Recruiting |
NCT05758337 -
Vibropneumostimulation in the Rehabilitation After Dental Implantation
|
N/A | |
Recruiting |
NCT05741749 -
Immediate Implant Placement in the Posterior Region Combining Sealing Socket Abutment and Peri-implant Socket Filling.
|
N/A | |
Recruiting |
NCT04093583 -
Randomized Clinical Trial, Conventional Treatment-controlled, Studying the Efficacy of Plasma Rich in Growth Factor (PRGF®) in Alveolar Ridge Preservation After Simple Exodontia in the Anterior Region of Maxilla.
|
Phase 3 | |
Completed |
NCT00066014 -
Clinical Investigation of Mandibular Implant Overdenture
|
Phase 2 | |
Completed |
NCT05843526 -
Influence of Implant Component Materials on Peri-implant Soft Tissue Horst Response.
|
N/A | |
Completed |
NCT06323993 -
The Effect of Different Window-preparation Approaches on the Clinical Outcomes of Lateral Sinus Floor Elevation
|
||
Not yet recruiting |
NCT06044246 -
Influence of Human Platelet Derivatives on Dental Implant
|
N/A | |
Not yet recruiting |
NCT03164759 -
Correlation Between Radiographic Bone Density in CBCT and Implant Stability Quotient Value: Clinical Observational Study
|
N/A | |
Completed |
NCT04950491 -
Patient-reported Outcome Measures Comparing Static Computer-aided Implant Surgery and Conventional Implant Surgery
|
N/A | |
Recruiting |
NCT05938868 -
Low Intensity Pulsed Ultrasound Versus Low Level Laser Therapy Post Dental Implant
|
N/A | |
Not yet recruiting |
NCT00519571 -
Evaluation of the Safety and Efficacy of Using ImplantLock Device - Dental Implant Accessory
|
N/A | |
Recruiting |
NCT05817526 -
BMAC Loaded Collagen Jumping the Gap Around Immediate Implants
|
N/A | |
Completed |
NCT03222219 -
Implant Insertion Torque and Primary Stability
|
||
Completed |
NCT04346706 -
Immediate Implant Placement in Fresh Extraction Sockets and Delayed Implants in Healed Sockets.
|
N/A | |
Recruiting |
NCT05105113 -
Evaluation of Survival and Success Rates of Zirzonia Dental Implants
|
N/A | |
Recruiting |
NCT05983718 -
A Study of Surgical Guide Assisted Dental Implantation in Bangladesh
|
N/A | |
Withdrawn |
NCT01154868 -
Clinical and Histological Evaluation of Healos® for Alveolar Ridge Augmentation
|
Phase 4 | |
Completed |
NCT03915509 -
Evaluation Of The Effect Of Surface Properties On The Stabılıty Of The Different Implants
|
N/A | |
Completed |
NCT06176287 -
Assessment of Pain Associated With Insertion Torque and Correlation of Primary Implant Stability Measurement Methods
|
N/A |