Clinical Trial Summary

The dental implant placed freehand with a digital planing is vastly increasing. The accuracy between the planned and the placed implants still not well determined. Between a single implant and a full mouth rehabilitation, the precision is very wide. A precision scale must be settled according to each indication in order to offer the clinician a safety and a predictability for his procedures.


Description:

In this paper the investigators report an original research evaluating the accuracy of computer-guided implant placement in posterior edentulous mandibular spaces. In this randomized controlled trial, several factors were evaluated such as primary implant stability, possibility of immediate loading, displacement at crestal and apical levels, angle of deviation, surgical guide design, computer-aided design and computer-aided manufacturing accuracy, and variance between different implant macro-geometries and lengths. As exhaustive description of the assessment techniques as well as the statistic results were also presented in this article. Nowadays, the use of guided surgery is vastly increasing in a daily dental practice. In the "Era of Digital Dentistry", it is of utmost importance to evaluate the accuracy and precision of the computer-guided techniques in order to determine their limits, avoid risks (adjacent anatomical structures, limited crestal volume, immediate loading), and apply them in safe manner. Evidence-based scientific data on this matter is still deficient. In these terms, the investigators consider it very interesting and of high clinical value for all oral surgeons and dental practitioners to evaluate in a clinical research the precision and distortion of computer-guided implant surgery.


Recruitment information / eligibility

Status Completed
Enrollment 13
Est. completion date August 15, 2023
Est. primary completion date May 2, 2023
Accepts healthy volunteers
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - Acceptable oral hygiene with no signs of active periodontal disease or local infection - American Society of Anesthesiologists (ASA) physical status classification 1 and 2 - Non or Light smoking (< 10 cigarettes per day) - Acceptable intermaxillary space (44 mm minimum) - Minimal crestal width of 5.5mm - Minimal residual bone height of 10mm above the alveolar nerve canal Exclusion Criteria: - Head and neck irradiation - Bone grafted sites - Severe bruxism - Cone Beam Computed tomography with exaggerated artifacts - Limited intermaxillary space

Study Design


Related Conditions & MeSH terms


Intervention

Procedure:
Computer Implant guided Surgery
Dental implant placed using printed guide after a digital planification on a superimposed 3D surface scan and a 3D Cone Beam imaging of the jaw.

Locations

Country Name City State
Lebanon Saint Joseph University of Beirut/Dental school Beirut

Sponsors (1)

Lead Sponsor Collaborator
Saint-Joseph University

Country where clinical trial is conducted

Lebanon, 

References & Publications (5)

Arisan V, Karabuda CZ, Ozdemir T. Implant surgery using bone- and mucosa-supported stereolithographic guides in totally edentulous jaws: surgical and post-operative outcomes of computer-aided vs. standard techniques. Clin Oral Implants Res. 2010 Sep;21(9):980-8. doi: 10.1111/j.1600-0501.2010.01957.x. Epub 2010 May 24. — View Citation

Li J, Chen Z, Chan HL, Sinjab K, Yu H, Wang HL. Does flap opening or not influence the accuracy of semi-guided implant placement in partially edentulous sites? Clin Implant Dent Relat Res. 2019 Dec;21(6):1253-1261. doi: 10.1111/cid.12847. Epub 2019 Oct 23. — View Citation

Tahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C. The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis. Clin Oral Implants Res. 2018 Oct;29 Suppl 16:416-435. doi: 10.1111/clr.13346. — View Citation

van Steenberghe D, Molly L, Jacobs R, Vandekerckhove B, Quirynen M, Naert I. The immediate rehabilitation by means of a ready-made final fixed prosthesis in the edentulous mandible: a 1-year follow-up study on 50 consecutive patients. Clin Oral Implants Res. 2004 Jun;15(3):360-5. doi: 10.1111/j.1600-0501.2004.01069.x. — View Citation

Younes F, Cosyn J, De Bruyckere T, Cleymaet R, Bouckaert E, Eghbali A. A randomized controlled study on the accuracy of free-handed, pilot-drill guided and fully guided implant surgery in partially edentulous patients. J Clin Periodontol. 2018 Jun;45(6):721-732. doi: 10.1111/jcpe.12897. Epub 2018 May 10. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Assess Accuracy of Implant Placement in Vertical Displacement (VD). Evaluate the accuracy of implant placement by comparing the planned positions (from the computer) with the actual positions of the placed implants (using the printed guide). The tool to assess the accuracy/deviation is a software that superimpose two "Digital Imaging and Communications in Medicine" (DCM) Files of the planned and the actual position implants. the first DCM issued from the planning software and second DCM file after scanning the implant in the jaw. The first outcome measure was provided to calculate the amount of distortion in millimeter (mm) for the Vertical Displacement (VD) (mm). 4 months
Primary Assess Accuracy of Implant Placement in Horizontal Displacement (HD) Evaluate the accuracy of implant placement by comparing the planned positions (from the computer) with the actual positions of the placed implants (using the printed guide). The tool to assess the accuracy/deviation is a software that superimpose two "Digital Imaging and Communications in Medicine" (DCM) Files of the planned and the actual position implants. the first DCM issued from the planning software and second DCM file after scanning the implant in the jaw. The second outcome measure was provided to calculate the amount of distortion in millimeter (mm) for the Horizontal Displacement (HD). 4 months
Primary Assess Accuracy of Implant Placement in Error Depth (ED) Evaluate the accuracy of implant placement by comparing the planned positions (from the computer) with the actual positions of the placed implants (using the printed guide). The tool to assess the accuracy/deviation is a software that superimpose two "Digital Imaging and Communications in Medicine" (DCM) Files of the planned and the actual position implants. the first DCM issued from the planning software and second DCM file after scanning the implant in the jaw. The third outcome measure was provided to calculate the amount of distortion in millimeter (mm) for the Error Depth (ED) (mm). 4 months
Primary Assess Accuracy of Implant Placement in Error Angle (EA) Evaluate the accuracy of implant placement by comparing the planned positions (from the computer) with the actual positions of the placed implants (using the printed guide). The tool to assess the accuracy/deviation is a software that superimpose two "Digital Imaging and Communications in Medicine" (DCM) Files of the planned and the actual position implants. the first DCM issued from the planning software and second DCM file after scanning the implant in the jaw. The fourth outcome measure was provided to calculate the amount of distortion in in degree of the Error Angle (EA). 4 months
Secondary Evaluate Precision of the Printed Guide Assess how precisely the printed guide translates the planned positions to the actual implant placements. Using the same assessment tool as for the primary outcome measure. 4 months
Secondary Study Complications and Adverse Events Monitor and report any complications or adverse events associated with the use of the printed guide during implant placement. 4 months
See also
  Status Clinical Trial Phase
Enrolling by invitation NCT05053958 - Using Superimposition of Intra-Oral Scan and CBCT in Single Implant Restorations in Aesthetic Zone. N/A
Recruiting NCT04367766 - Management of the Fresh Extraction Socket in the Aesthetic Area N/A
Recruiting NCT06296459 - Radiographic Changes in the Maxillary Sinus Following Closed Sinus Augmentation N/A
Recruiting NCT06247098 - Evaluation of Sinus Augmentation Bone Healing Using Autograft and Xenograft Compared to Xenograft Alone N/A
Not yet recruiting NCT05988281 - Success of Implant Restorations After Immediate or Delayed Implant Placement With/Without Ridge Preservation N/A
Completed NCT04340830 - The Effect of Smoking on Dimensional Changes of Free Gingival Graft Around Dental Implants N/A
Completed NCT06404385 - Accuracy of Static Computer-assisted Implant Surgery in Distal Free-end Scenarios N/A
Recruiting NCT05405179 - Simultaneous Dental Implant in Free Vascularized Bone Flaps for Jaw Reconstruction N/A
Completed NCT06138392 - Long-term Study in Early Loaded Hydrophilic Surface Implants
Completed NCT04332679 - Non-resorbable Membranes Versus Titanium Meshes and Resorbable Membranes N/A
Completed NCT06127576 - Biomechanical Informational Effect of Innovative Double or Triple Dental Abutment-implant: Case-series
Recruiting NCT06059573 - The Accuracy of Dental Implant Placement Using Robotic System-assisted Surgery and Freehand Surgery N/A
Recruiting NCT06068231 - A Study of Early Loading of Implants in the Maxillary Anterior Region With Alveolar Bone Defects N/A
Completed NCT03774888 - To Compare Different Soft Tissue Grafts at the Time of Lateral Ridge Augmentation Procedure. N/A
Completed NCT02864862 - Esthetic Outcomes Following Immediate Implant Combine With Soft Tissue Augmentation Phase 4
Completed NCT02444052 - Evaluation of Zimmer Puros® Allograft vs. Creos™ Allograft for Alveolar Ridge Preservation N/A
Completed NCT04861662 - Effect of Keratinized Mucosa on Peri-implant Health N/A
Not yet recruiting NCT04541641 - Clinical Evaluation of Stability of Implants Placed in Partially Edentulous Maxilla With Poor Bone Quality Via New Reverse Drilling Technique Versus Osteotome Technique. N/A
Completed NCT03888339 - Influence of Abutment Shape on Peri-implant Marginal Bone Loss N/A
Recruiting NCT06231134 - Diode Laser 940 nm Versus Electrosurgical Device During Second Stage Implant Surgery on Bone and Soft Tissue Healing N/A