Dental Implant Clinical Trial
Official title:
Accuracy of Computer- Guided Implant Surgery in Partially Edentulous Patients: a Prospective Observational Study.
NCT number | NCT06277076 |
Other study ID # | FMD1234 |
Secondary ID | |
Status | Completed |
Phase | |
First received | |
Last updated | |
Start date | January 28, 2023 |
Est. completion date | August 15, 2023 |
Verified date | February 2024 |
Source | Saint-Joseph University |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Observational [Patient Registry] |
The dental implant placed freehand with a digital planing is vastly increasing. The accuracy between the planned and the placed implants still not well determined. Between a single implant and a full mouth rehabilitation, the precision is very wide. A precision scale must be settled according to each indication in order to offer the clinician a safety and a predictability for his procedures.
Status | Completed |
Enrollment | 13 |
Est. completion date | August 15, 2023 |
Est. primary completion date | May 2, 2023 |
Accepts healthy volunteers | |
Gender | All |
Age group | 18 Years and older |
Eligibility | Inclusion Criteria: - Acceptable oral hygiene with no signs of active periodontal disease or local infection - American Society of Anesthesiologists (ASA) physical status classification 1 and 2 - Non or Light smoking (< 10 cigarettes per day) - Acceptable intermaxillary space (44 mm minimum) - Minimal crestal width of 5.5mm - Minimal residual bone height of 10mm above the alveolar nerve canal Exclusion Criteria: - Head and neck irradiation - Bone grafted sites - Severe bruxism - Cone Beam Computed tomography with exaggerated artifacts - Limited intermaxillary space |
Country | Name | City | State |
---|---|---|---|
Lebanon | Saint Joseph University of Beirut/Dental school | Beirut |
Lead Sponsor | Collaborator |
---|---|
Saint-Joseph University |
Lebanon,
Arisan V, Karabuda CZ, Ozdemir T. Implant surgery using bone- and mucosa-supported stereolithographic guides in totally edentulous jaws: surgical and post-operative outcomes of computer-aided vs. standard techniques. Clin Oral Implants Res. 2010 Sep;21(9):980-8. doi: 10.1111/j.1600-0501.2010.01957.x. Epub 2010 May 24. — View Citation
Li J, Chen Z, Chan HL, Sinjab K, Yu H, Wang HL. Does flap opening or not influence the accuracy of semi-guided implant placement in partially edentulous sites? Clin Implant Dent Relat Res. 2019 Dec;21(6):1253-1261. doi: 10.1111/cid.12847. Epub 2019 Oct 23. — View Citation
Tahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C. The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis. Clin Oral Implants Res. 2018 Oct;29 Suppl 16:416-435. doi: 10.1111/clr.13346. — View Citation
van Steenberghe D, Molly L, Jacobs R, Vandekerckhove B, Quirynen M, Naert I. The immediate rehabilitation by means of a ready-made final fixed prosthesis in the edentulous mandible: a 1-year follow-up study on 50 consecutive patients. Clin Oral Implants Res. 2004 Jun;15(3):360-5. doi: 10.1111/j.1600-0501.2004.01069.x. — View Citation
Younes F, Cosyn J, De Bruyckere T, Cleymaet R, Bouckaert E, Eghbali A. A randomized controlled study on the accuracy of free-handed, pilot-drill guided and fully guided implant surgery in partially edentulous patients. J Clin Periodontol. 2018 Jun;45(6):721-732. doi: 10.1111/jcpe.12897. Epub 2018 May 10. — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Assess Accuracy of Implant Placement in Vertical Displacement (VD). | Evaluate the accuracy of implant placement by comparing the planned positions (from the computer) with the actual positions of the placed implants (using the printed guide). The tool to assess the accuracy/deviation is a software that superimpose two "Digital Imaging and Communications in Medicine" (DCM) Files of the planned and the actual position implants. the first DCM issued from the planning software and second DCM file after scanning the implant in the jaw. The first outcome measure was provided to calculate the amount of distortion in millimeter (mm) for the Vertical Displacement (VD) (mm). | 4 months | |
Primary | Assess Accuracy of Implant Placement in Horizontal Displacement (HD) | Evaluate the accuracy of implant placement by comparing the planned positions (from the computer) with the actual positions of the placed implants (using the printed guide). The tool to assess the accuracy/deviation is a software that superimpose two "Digital Imaging and Communications in Medicine" (DCM) Files of the planned and the actual position implants. the first DCM issued from the planning software and second DCM file after scanning the implant in the jaw. The second outcome measure was provided to calculate the amount of distortion in millimeter (mm) for the Horizontal Displacement (HD). | 4 months | |
Primary | Assess Accuracy of Implant Placement in Error Depth (ED) | Evaluate the accuracy of implant placement by comparing the planned positions (from the computer) with the actual positions of the placed implants (using the printed guide). The tool to assess the accuracy/deviation is a software that superimpose two "Digital Imaging and Communications in Medicine" (DCM) Files of the planned and the actual position implants. the first DCM issued from the planning software and second DCM file after scanning the implant in the jaw. The third outcome measure was provided to calculate the amount of distortion in millimeter (mm) for the Error Depth (ED) (mm). | 4 months | |
Primary | Assess Accuracy of Implant Placement in Error Angle (EA) | Evaluate the accuracy of implant placement by comparing the planned positions (from the computer) with the actual positions of the placed implants (using the printed guide). The tool to assess the accuracy/deviation is a software that superimpose two "Digital Imaging and Communications in Medicine" (DCM) Files of the planned and the actual position implants. the first DCM issued from the planning software and second DCM file after scanning the implant in the jaw. The fourth outcome measure was provided to calculate the amount of distortion in in degree of the Error Angle (EA). | 4 months | |
Secondary | Evaluate Precision of the Printed Guide | Assess how precisely the printed guide translates the planned positions to the actual implant placements. Using the same assessment tool as for the primary outcome measure. | 4 months | |
Secondary | Study Complications and Adverse Events | Monitor and report any complications or adverse events associated with the use of the printed guide during implant placement. | 4 months |
Status | Clinical Trial | Phase | |
---|---|---|---|
Enrolling by invitation |
NCT05053958 -
Using Superimposition of Intra-Oral Scan and CBCT in Single Implant Restorations in Aesthetic Zone.
|
N/A | |
Recruiting |
NCT04367766 -
Management of the Fresh Extraction Socket in the Aesthetic Area
|
N/A | |
Recruiting |
NCT06296459 -
Radiographic Changes in the Maxillary Sinus Following Closed Sinus Augmentation
|
N/A | |
Recruiting |
NCT06247098 -
Evaluation of Sinus Augmentation Bone Healing Using Autograft and Xenograft Compared to Xenograft Alone
|
N/A | |
Not yet recruiting |
NCT05988281 -
Success of Implant Restorations After Immediate or Delayed Implant Placement With/Without Ridge Preservation
|
N/A | |
Completed |
NCT04340830 -
The Effect of Smoking on Dimensional Changes of Free Gingival Graft Around Dental Implants
|
N/A | |
Completed |
NCT06404385 -
Accuracy of Static Computer-assisted Implant Surgery in Distal Free-end Scenarios
|
N/A | |
Recruiting |
NCT05405179 -
Simultaneous Dental Implant in Free Vascularized Bone Flaps for Jaw Reconstruction
|
N/A | |
Completed |
NCT06138392 -
Long-term Study in Early Loaded Hydrophilic Surface Implants
|
||
Completed |
NCT04332679 -
Non-resorbable Membranes Versus Titanium Meshes and Resorbable Membranes
|
N/A | |
Completed |
NCT06127576 -
Biomechanical Informational Effect of Innovative Double or Triple Dental Abutment-implant: Case-series
|
||
Recruiting |
NCT06059573 -
The Accuracy of Dental Implant Placement Using Robotic System-assisted Surgery and Freehand Surgery
|
N/A | |
Recruiting |
NCT06068231 -
A Study of Early Loading of Implants in the Maxillary Anterior Region With Alveolar Bone Defects
|
N/A | |
Completed |
NCT03774888 -
To Compare Different Soft Tissue Grafts at the Time of Lateral Ridge Augmentation Procedure.
|
N/A | |
Completed |
NCT02864862 -
Esthetic Outcomes Following Immediate Implant Combine With Soft Tissue Augmentation
|
Phase 4 | |
Completed |
NCT02444052 -
Evaluation of Zimmer Puros® Allograft vs. Creos™ Allograft for Alveolar Ridge Preservation
|
N/A | |
Completed |
NCT04861662 -
Effect of Keratinized Mucosa on Peri-implant Health
|
N/A | |
Not yet recruiting |
NCT04541641 -
Clinical Evaluation of Stability of Implants Placed in Partially Edentulous Maxilla With Poor Bone Quality Via New Reverse Drilling Technique Versus Osteotome Technique.
|
N/A | |
Completed |
NCT03888339 -
Influence of Abutment Shape on Peri-implant Marginal Bone Loss
|
N/A | |
Recruiting |
NCT06231134 -
Diode Laser 940 nm Versus Electrosurgical Device During Second Stage Implant Surgery on Bone and Soft Tissue Healing
|
N/A |