Clinical Trials Logo

Clinical Trial Summary

The aim was to compare two protocols for immediate implants with fixed provisional restoration, no grafting (trimodal approach=TA) versus grafting both osseous gap and peri-implant mucosa (trimodal approach with modification of the osseous and mucosal compartments =TAOM) by measuring the soft tissue changes overtime. The periodontal phenotype was registered, to investigate a relationship between its thickness and the clinical outcomes.


Clinical Trial Description

The study protocol was approved by the CEIm Quiron Salud Catalunya institutional research ethic committee (Approval code:2022/102_MAX:CEX). This prospective clinical study includes patients who were enrolled and treated in two private practices (GC and JGF). All eligible patients were consecutively selected for two study groups receiving immediately placed flapless implants and the provisional restoration. Patients were informed about the characteristics of the study and signed their informed consent before the study began. Patient population Patients in need of single implant supported restorations in the anterior maxilla (canines, lateral and central incisors) were selected for this study. The indications for tooth extractions were cavities, endodontic complications (e.g., root fracture), internal resorption and prosthetic reasons. The patients had to fulfil the following inclusion and exclusion criteria: Inclusion criteria: - ≥18 years of age - Need for tooth extraction in the anterior maxilla (13-23) due to cavities, internal resorption, fractures, restorative problems, endodontic complications and prosthetic reasons. - The failing tooth has adjacent and opposing natural teeth - Adequate oral hygiene (Bleeding on probing <20%; Plaque index <20%); - Absence of active and uncontrolled periodontal disease - Sufficient mesial-distal and interocclusal space for implant placement and definitive restoration - Sufficient interocclusal space to design a non-occluding provisional restoration Exclusion criteria: - Systemic metabolic or osseous disease that could compromise peri-implant tissue healing - Acute infection in the treatment area - Absence of one or both adjacent teeth - Non-integrity of the buccal bone wall (dehiscence or fenestration) observed during surgery, or when tooth extraction has altered the integrity of the osseous and gingival architecture The participants were screened by two investigators (GC & JGF) and comprised two consecutive study groups with the following interventions: 1. Flapless immediate implant placement and provisional restoration (trimodal approach: TA) (n=15). 2. Flapless immediate implant placement and provisional restoration with alveolar filling and connective tissue graft (trimodal approach with osseous and mucosal compartment modification: TAOM) (n=16). Treatment protocol and follow-up Four visits were intended to be delivered in each participant. Following the selection of candidates, study casts were prepared for all patients as well as preoperative photographs and parallel periapical radiographs of the problematic tooth. Rigid stents were prepared with light-cured resin, covering the incisal edges of at least one adjacent tooth on each side of the target tooth. Measurements from reference points to mid-buccal soft tissue height and mesial and distal papillae were recorded at T0. The stents were > 2 mm thick so they could be modified to allow for a perfect fit over the final restoration. All surgical procedures were performed by two experienced surgeons and investigators (GC& JGF). Without raising a mucoperiosteal flap, a careful tooth extraction was performed, allowing for the preservation of soft and hard tissues. In 10 patients, the Benex Extractor® (Benex Root Extraction System, Hager and Meisinger GMbH, Neuss, Germany) was used to ensure atraumatic extraction. Then, a detailed examination of the buccal bone wall was carried out to verify its integrity. In the cases when the integrity of the bone wall was in question, the patient was excluded from the study and the implant was placed by means of conventional protocols. Measurement of the total periodontal thickness (phenotype) was taken at this time by means of an analogic calliper located 5 mm apical to the buccal gingival margin, to locate the bundle bone level. Then, the implant bed was prepared on the palatal side of the extraction socket in accordance with the manufacturer's instructions (Bone Level -BL- and Tissue Level -TL-, Straumann AG, Switzerland; Thoma et al., 2021). The implant was placed securing the ideal position at a depth of 2mm for the TL implant and 4mm for the BL implant and in a palatal position allowing for a direct screw-retained restoration (1-3 mm from the bone wall) for all implants. It was also verified that the wall of the post-extraction socket was not perforated during implant bed preparation. The implant had to show good primary stability in its ideal position, in order to avoid being excluded from the study. In the TA group, no material was used to fill the gap between the implant and the osseous wall and no soft tissue graft was attempted either. In the TAOM group, the gap between the implant and the facial bone wall was grafted with inorganic bovine bone (Geistlich Bio-Oss®; Geistlich Pharma AG, Wolhusen, Switzerland) and, in addition, a connective tissue graft (CTG) was harvested from the anterior palate region and placed submucosally on the labial bone plate by means of an envelope technique. Following implant placement, an acrylic resin implant-supported provisional restoration was prepared, adapted and delivered for all implants. All provisional restorations were directly screw-retained and designed with no occlusal contacts, neither in maximum intercuspal position nor in excursive movements. The emergence profile was mainly flat or concave in interproximal and palatal sides, and slightly convex in the buccal aspect to support the soft tissues for the TA group. In the TAOM group, it was slightly concave to provide space for the soft-tissue graft and avoid isquemia in the marginal mucosa. Intra-oral radiographs were taken to check implant position and the fit of the restoration. Systemic antibiotics (Azitromicin-500mg/24h/3days) and anti-inflammatories (Dexketoprofen-25mg/8h/3days) were prescribed, together with a clorhexidine 0.20 % gel twice a day for one week. Patients were then recalled for a post-operative check-up and sutures were removed after 14 days. At 3 months, final impressions were made. After abutment selection and bisque try-ins, final restorations were permanently placed at 4 months. The tooth-supported acrylic resin measuring stent was then adapted to allow for a complete fit on the incisal edges of both neighbouring teeth, to ensure a reliable positioning and measurement reference. The first measurement was at day 0 (Immediate implant placement and provisionalisation). Patient recall appointments for examinations and measurements took place at 3, 6 and 12 months. No activities were performed to increase compliance or adherence in the selected patients beyong compliance of a good clinical practice. Outcome measures The primary outcome variable of this study was the vertical midfacial soft tissue change from baseline (before tooth extraction) to 12 months following implant placement. The secondary outcome measures were mesial and distal papillae vertical changes, periodontal phenotype at implant site, and mechanical complications. The clinical outcomes were measured as follows: - Vertical soft tissue changes were calculated through the distance from reference measuring points on the stent to mesial (MP) and distal (DP) papillae, and gingival zenith (Z) of the implant restoration. Distances were measured by means of a precision digital calliper that can display measurements as small as tenths of a millimetre. Three dimples were marked in the stent, in approximately the vertical projection of papillae and zenith (Supplementary figure 1a). Measurements were taken before tooth extraction (baseline) T0 and at 3 (T3), 6 (T6) and 12 (T12) months following the intervention. - Periodontal phenotype thickness was measured by means of an analogical calliper that was able to show tenths of a millimetre. It was located 5 mm apical to the buccal gingival margin immediately after tooth extraction. - Mechanical complications were assessed and included: screw loosening, loss of retention, chipping of acrylic or porcelain complications. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05927181
Study type Interventional
Source Universidad Complutense de Madrid
Contact
Status Completed
Phase N/A
Start date April 2009
Completion date February 2020

See also
  Status Clinical Trial Phase
Enrolling by invitation NCT05053958 - Using Superimposition of Intra-Oral Scan and CBCT in Single Implant Restorations in Aesthetic Zone. N/A
Recruiting NCT04367766 - Management of the Fresh Extraction Socket in the Aesthetic Area N/A
Recruiting NCT06296459 - Radiographic Changes in the Maxillary Sinus Following Closed Sinus Augmentation N/A
Recruiting NCT06247098 - Evaluation of Sinus Augmentation Bone Healing Using Autograft and Xenograft Compared to Xenograft Alone N/A
Not yet recruiting NCT05988281 - Success of Implant Restorations After Immediate or Delayed Implant Placement With/Without Ridge Preservation N/A
Completed NCT04340830 - The Effect of Smoking on Dimensional Changes of Free Gingival Graft Around Dental Implants N/A
Completed NCT06404385 - Accuracy of Static Computer-assisted Implant Surgery in Distal Free-end Scenarios N/A
Recruiting NCT05405179 - Simultaneous Dental Implant in Free Vascularized Bone Flaps for Jaw Reconstruction N/A
Completed NCT06138392 - Long-term Study in Early Loaded Hydrophilic Surface Implants
Completed NCT04332679 - Non-resorbable Membranes Versus Titanium Meshes and Resorbable Membranes N/A
Completed NCT06127576 - Biomechanical Informational Effect of Innovative Double or Triple Dental Abutment-implant: Case-series
Recruiting NCT06059573 - The Accuracy of Dental Implant Placement Using Robotic System-assisted Surgery and Freehand Surgery N/A
Recruiting NCT06068231 - A Study of Early Loading of Implants in the Maxillary Anterior Region With Alveolar Bone Defects N/A
Completed NCT03774888 - To Compare Different Soft Tissue Grafts at the Time of Lateral Ridge Augmentation Procedure. N/A
Completed NCT02864862 - Esthetic Outcomes Following Immediate Implant Combine With Soft Tissue Augmentation Phase 4
Completed NCT02444052 - Evaluation of Zimmer Puros® Allograft vs. Creos™ Allograft for Alveolar Ridge Preservation N/A
Completed NCT04861662 - Effect of Keratinized Mucosa on Peri-implant Health N/A
Not yet recruiting NCT04541641 - Clinical Evaluation of Stability of Implants Placed in Partially Edentulous Maxilla With Poor Bone Quality Via New Reverse Drilling Technique Versus Osteotome Technique. N/A
Completed NCT03888339 - Influence of Abutment Shape on Peri-implant Marginal Bone Loss N/A
Recruiting NCT06231134 - Diode Laser 940 nm Versus Electrosurgical Device During Second Stage Implant Surgery on Bone and Soft Tissue Healing N/A