Dental Implant Clinical Trial
Official title:
Evaluation of Patient Reported Outcome Measures and Clinical Performance of Implant Supported Overdentures With Two Different Attachment Systems: A Randomized Cross Over Clinical Study
Edentulous patients commonly experience a deterioration in the quality of life; both in terms of oral and general health. Studies demonstrated that conventional dentures do not adequately restore masticatory function nor quality of life. In contrast, implant-supported overdentures are considered the standard of care for edentulous patients as they offer a more stable prosthesis that ultimately results in improved oral function and patient satisfaction. Precision attachments such as studs, magnets, telescopic crowns or a bars are commonly used for implant supported overdentures. Implant overdentures supported by stud attachments gained popularity for the rehabilitation of edentulous patients as they are self-aligning, offer dual retention and compensate for divergence between implants up to angles of 40 degrees. However, it has been documented that the stud attachment system (Locators) requires a high frequency of maintenance, particularly with regard to the replacement of the matrix. In order to overcome some of these limitations of existing attachment systems, a newer system was developed consisting of a matrix made of polyetheretherketone (PEEK) instead of a polymeric material. This system has an amorphous diamond like carbon-based abutment coating (ADLC) and it was claimed to be more resistant to wear. Clinically and in vitro, no comparative studies have been performed addressing wear and retention of the traditional stud attachment and the newer ADLC attachment. Thus, the aim of the present study is to clinically and in vitro evaluate the ADLC and study attachment system.
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Enrolling by invitation |
NCT05053958 -
Using Superimposition of Intra-Oral Scan and CBCT in Single Implant Restorations in Aesthetic Zone.
|
N/A | |
Recruiting |
NCT04367766 -
Management of the Fresh Extraction Socket in the Aesthetic Area
|
N/A | |
Recruiting |
NCT06296459 -
Radiographic Changes in the Maxillary Sinus Following Closed Sinus Augmentation
|
N/A | |
Recruiting |
NCT06247098 -
Evaluation of Sinus Augmentation Bone Healing Using Autograft and Xenograft Compared to Xenograft Alone
|
N/A | |
Not yet recruiting |
NCT05988281 -
Success of Implant Restorations After Immediate or Delayed Implant Placement With/Without Ridge Preservation
|
N/A | |
Completed |
NCT04340830 -
The Effect of Smoking on Dimensional Changes of Free Gingival Graft Around Dental Implants
|
N/A | |
Completed |
NCT06404385 -
Accuracy of Static Computer-assisted Implant Surgery in Distal Free-end Scenarios
|
N/A | |
Recruiting |
NCT05405179 -
Simultaneous Dental Implant in Free Vascularized Bone Flaps for Jaw Reconstruction
|
N/A | |
Completed |
NCT06138392 -
Long-term Study in Early Loaded Hydrophilic Surface Implants
|
||
Completed |
NCT04332679 -
Non-resorbable Membranes Versus Titanium Meshes and Resorbable Membranes
|
N/A | |
Completed |
NCT06127576 -
Biomechanical Informational Effect of Innovative Double or Triple Dental Abutment-implant: Case-series
|
||
Recruiting |
NCT06059573 -
The Accuracy of Dental Implant Placement Using Robotic System-assisted Surgery and Freehand Surgery
|
N/A | |
Recruiting |
NCT06068231 -
A Study of Early Loading of Implants in the Maxillary Anterior Region With Alveolar Bone Defects
|
N/A | |
Completed |
NCT03774888 -
To Compare Different Soft Tissue Grafts at the Time of Lateral Ridge Augmentation Procedure.
|
N/A | |
Completed |
NCT02864862 -
Esthetic Outcomes Following Immediate Implant Combine With Soft Tissue Augmentation
|
Phase 4 | |
Completed |
NCT02444052 -
Evaluation of Zimmer Puros® Allograft vs. Creos™ Allograft for Alveolar Ridge Preservation
|
N/A | |
Completed |
NCT04861662 -
Effect of Keratinized Mucosa on Peri-implant Health
|
N/A | |
Not yet recruiting |
NCT04541641 -
Clinical Evaluation of Stability of Implants Placed in Partially Edentulous Maxilla With Poor Bone Quality Via New Reverse Drilling Technique Versus Osteotome Technique.
|
N/A | |
Completed |
NCT03888339 -
Influence of Abutment Shape on Peri-implant Marginal Bone Loss
|
N/A | |
Recruiting |
NCT06231134 -
Diode Laser 940 nm Versus Electrosurgical Device During Second Stage Implant Surgery on Bone and Soft Tissue Healing
|
N/A |