Clinical Trials Logo

Clinical Trial Summary

Monitoring of a person's physical status is a key point for maintaining of "healthy life". Wearable devices provide a unique possibility for real-time monitoring. This study aims to estimate the accuracy of Spectrophon Dehydration Body Monitor (DBM) incorporated in smartwatch Samsung Gear S2 and sport band Samsung Gear Fit2 by comparing data obtained by DBM with the total weight lost during exertion.


Clinical Trial Description

Reduced physical activity is considered as a risk factor for obesity, diabetes, cancer and depression. A proper exercise program can mitigate cognitive and physical decline associated with ageing. Existing general guidelines for physical activity are not universal or appropriate for every person. A personalized approach based on a subject age and unique combination of different physiological parameters would serve as a solution for finding optimal training protocols for individuals. Hence, monitoring basic physiological and biochemical parameters and obtaining information reflecting the body metabolic state is necessary for health status estimation to develop the abovementioned personally-oriented training protocols. Dehydration Body Monitor (DBM) developed by Spectrophon L.T.D. can measure sweat lost, salt concentration in sweat, and sweating dynamics, which can be used for personal physical status monitoring. This is important not only for controlling appropriate body hydration level but also for keeping kidneys "healthy". Currently, only few DBM tools are available on the market, so there is a growing need for new effective accurate real-time DBM sensors.

The main objective of current study is to estimate the accuracy of Spectrophon DBM incorporated in smartwatch Samsung Gear S2 and sport band Samsung Gear Fit2. The secondary aim of the study is to evaluate the safety-in-use of Spectrophon DBM.

Tested device:

Name: Dehydration Body Monitor; Source: Spectrophon, L.T.D.; Model: SP-DBM Firmware version: 1.5

4. Experimental Design Healthy adults (n=200) in different age and gender groups were recruited for the study. Samsung Gear S2 smartwatch with Spectrophon DBM attached to the bottom of the smartwatch were placed on the right wrist of each participant. At the same time, Samsung Gear Fit2 sport band with Spectrophon DBM attached to the bottom of the band was placed on the left wrist of the participant. Each participant was subjected to moderate physical activity. Data from Samsung Gear S2 and Samsung Gear Fit2 was obtained simultaneously. In parallel, subject weight was also monitored using commercially available digital balancers (Shekel B-200-P).

The evaluation of the measurement accuracy of the Spectrophon DBM was defined as the difference between subject weight change during the exertion (due to sweating and water consumption) and the volume of sweat detected by Spectrophon DBM.

5. Procedures: Participants were weighed prior to the experiment (no clothing after maximal drying) and then subjected to physical activity (walking on the treadmill).

Total duration of study: 90 minutes

5.2 Intensity of exercises:

Participants could choose high or low intensity of exertion:

1. High: up to 6.5km/h;

2. Low: yo to 6.0km/h; 5.3 Data recording: After DBM application was activated, DBM started recording data (sweat rate and total salt in sweat) every 20 sec. and automatically saved results into archive on a mobile phone linked to Samsung Gear S2 or Samsung Gear Fit2 by Bluetooth. Manual recording of data was conducted during breaks Participants were also weighed during each break (no clothing after maximal drying).

5.4. Drinking During the procedure, subjects could drink up to 500 ml of water. The weight of the bottle was measured and recorded after drinking during breaks. The difference was subtracted to the weight loss calculation.

5.5 Restrictions:

In this experiment, the following was avoided:

1. Urination during test (empty before T0)

2. Weight loss should not exceed 2%

Participants could cancel the experiment at any point of the procedure if desired. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03229109
Study type Interventional
Source Tirat Carmel Mental Health Center
Contact
Status Completed
Phase N/A
Start date May 3, 2017
Completion date July 27, 2017

See also
  Status Clinical Trial Phase
Not yet recruiting NCT04079543 - NPO and Patient Satisfaction in the Cath Lab N/A
Recruiting NCT06063655 - Effects of Two Novel Hydration Beverage Formulas on Rehydration in Adults N/A
Completed NCT05111392 - Hydration Dynamics and Influence of Beverage Composition Phase 1/Phase 2
Terminated NCT02486224 - Metabolomic Analysis of the Impacts of Hydration Status on Exercise Performance N/A
Recruiting NCT02249845 - Comparing the Diagnostic Accuracy of Clinical Dehydration Scales Among Small Children N/A
Completed NCT01285713 - IV Glucose for Dehydration Treatment Phase 2
Withdrawn NCT00691275 - Efficacy Study of IV Fluids Only vs Ondansetron to Treat Dehydration N/A
Completed NCT00360204 - Improving Health Outcomes for New Mothers and Babies Phase 3
Completed NCT00370968 - Zinc-ORS in Severe and Complicated Acute Diarrhea Phase 2/Phase 3
Completed NCT04076995 - INDIGO-2: The Effect of High Water Intake on Glucose Regulation in Low-drinkers N/A
Recruiting NCT05768789 - Buoy Electrolyte Study on Hydration Status of Active Men and Women N/A
Not yet recruiting NCT05428228 - Clinical Study to Evaluate the Effects of Two Novel Hydration Beverage Formulas on Rehydration in Healthy Adults N/A
Completed NCT04997031 - Tap Water Intake and Perceptions in US Latinx Adults
Completed NCT04536324 - The Absorption Rate of Subcutaneous Infused Fluid
Completed NCT02926989 - Intravenous Fluids in Hospitalised Children Phase 4
Completed NCT04874584 - Culturally Tailored Nurse Coaching Study for Cancer Symptom Management N/A
Completed NCT02206581 - Using Hydration Monitor to Detect Changes in the Hydration Status Athletes N/A
Completed NCT02265575 - Hylenex-Assisted Resuscitation in Kenya (HARK) Trial for the Management of Dehydration Phase 2
Completed NCT01893853 - Fluid Balance During Exercise in the Heat With Water, Flavored Placebo, or a Carbohydrate-electrolyte Beverage Intake (The APEX Study) N/A
Completed NCT01503996 - Drinking Habits of Glaucoma Patients and Age Matched Controls N/A