Clinical Trials Logo

Clinical Trial Details — Status: Active, not recruiting

Administrative data

NCT number NCT04141098
Other study ID # CIP-003
Secondary ID
Status Active, not recruiting
Phase N/A
First received
Last updated
Start date October 10, 2019
Est. completion date August 31, 2022

Study information

Verified date July 2021
Source Spinal Stabilization Technologies
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This study will be a prospective, open-label, multi-center study that will collect safety data for the minimally invasive PerQdisc Nucleus Replacement Device deployed to reduce chronic low back pain.


Description:

This study will be a prospective, open-label, multi-center study that will collect safety and efficacy data for the minimally invasive PerQdisc Nucleus Replacement Device (NRD). Patients will have degenerative disc disease (DDD) in one or more lumbar discs. The NRD is used for surgical replacement of a single nucleus pulposus between spinal lumbar discs L1-S1 using an anterior or lateral transpsoas approach. Currently the surgical gold standard involves spinal fusion of the affected vertebral bodies, reducing range of motion and increasing stress on other vertebral bodies. The goal of nucleus replacement is to reduce chronic low back pain by maintaining disc height while preserving range of motion.


Recruitment information / eligibility

Status Active, not recruiting
Enrollment 9
Est. completion date August 31, 2022
Est. primary completion date February 28, 2022
Accepts healthy volunteers No
Gender All
Age group 21 Years to 60 Years
Eligibility Inclusion Criteria: - Patient is skeletally mature and between 21 and 60 years of age. - Patient has Degenerative Disc Disease (DDD) at one or more levels between L1 and S1 - History and clinical findings suggestive of symptomatic DDD: Darkened disc on MRI in T2 weighted images Patients with at least 6 months of low back pain (location defined as the space between the lower margin of the posterior rib cage and horizontal gluteal fold) that is resistant to nonsurgical conservative therapy. - Patient has adequate disc height (~6mm) at the level to be treated - Patient has pre-operative Oswestry Low Back Disability score of greater than or equal to 40 (0-100 scale). - Patient has pre-operative back pain VAS score of greater than or equal to 40 (0-100 scale) - Patient has received conservative, non-surgical treatment for back pain for a minimum of 6 months. - Patient has signed the approved Informed Consent Form. Exclusion Criteria: - Patient has had prior lumbar spine surgery - Spinal fusion at any level - Patient has ankylosing spondylitis or other spondyloarthropathy. - Patient has isthmic spondylolisthesis or degenerative spondylolisthesis greater than 2 mm. - Patient has congenital moderate or severe spinal stenosis or epidural lipomatosis. - Patient has significant facet disease. - Patient has had prior lumbar spine surgery - Spinal fusion at any level - Patient has any known active malignancy. - Patient has previously undergone or currently on immunosuppressive therapy. Steroids used to treat inflammation are allowed. - Patient has active local or systemic infection. - Patient has been diagnosed with hepatitis, rheumatoid arthritis, lupus erythematosus, or other autoimmune disease, including AIDS, ARC and HIV. - Patient has diabetes mellitus (Type 1 or 2), requiring daily insulin management. - Patient is pregnant or plans to become pregnant during the course of the study. Pregnancy ruled out by urine or serum HCG. - Patient has a known allergy to silicone (polymer and balloon material) or barium sulfate (polymer). - Patient participated in another investigational drug or device study within the past 30 days. - Patient belongs to a vulnerable population or has a condition such that his/her ability to provide informed consent, comply with follow-up requirements, or provide self- assessments is compromised (e.g. developmentally disabled, prisoner, chronic alcohol/ substance abuser) - Patient has a significant disc herniation at the level to be treated - Patient has a significant Schmorl's node in the level to be treated Intraoperative exclusion criteria: - Protrusion of the 20A imaging balloon up to or beyond the outer margin of the vertebra during the imaging steps. - Patient has a violated endplate as determined by imaging balloon during fluoroscopy - Patient has a disc space that is too narrow for implantation.

Study Design


Intervention

Device:
All patients that meet the inclusion/exclusion criteria will receive the PerQdisc® Nucleus Replacement Device.
All patients meeting all inclusion criteria and no exclusion criteria will be considered for nucleus replacement surgery following a review by the Medical Advisory Board. Any patient meeting any of the three intraoperative exclusion criteria will receive an alternative standard of care therapy.

Locations

Country Name City State
Paraguay Sanatorio Americano Asunción

Sponsors (1)

Lead Sponsor Collaborator
Spinal Stabilization Technologies

Country where clinical trial is conducted

Paraguay, 

Outcome

Type Measure Description Time frame Safety issue
Primary Post surgical change in degree of disability Patient reported outcomes for degree of disability will be monitored using the Oswestry Disability Index (scale of 0-100). Higher scores indicate greater level of disability. 6 months
Primary Post surgical change in back pain: Visual Analogue Scale Patient reported outcomes will be reported using the Visual Analogue Scale (0-100mm). Higher scores indicate greater levels of back pain. 6 months
See also
  Status Clinical Trial Phase
Recruiting NCT04848376 - Post-Market Clinical Follow-up Study of A-SPINE's Products
Active, not recruiting NCT05114135 - TLIF Osteo3 ZP Putty Study (Also Known as the TOP Fusion Study) N/A
Suspended NCT04735185 - Stem Cells vs. Steroids for Discogenic Back Pain N/A
Withdrawn NCT03223701 - Efficacy of Using Solum IV and BMC With GFC in TLIF Phase 4
Completed NCT04057235 - Retrospective Review of Integrity Implants FlareHawk® for Lumbar Fusion
Not yet recruiting NCT06000319 - Natural Matrix Protein™ (NMP™) Fibers in Cervical and Lumbar Interbody Fusion
Active, not recruiting NCT02969616 - Trinity Elite in Lumbar Fusion
Completed NCT02558621 - New Robotic Assistance System for Spinal Fusion Surgery N/A
Completed NCT02104167 - Retrospective/Prospective Data Collection on the LDR ROIC Interbody Fusion Device With VerteBRIDGE Plating
Completed NCT00965380 - Trinity Evolution in Posterior or Transforaminal Lumbar Interbody Fusion (PLIF/TLIF)
Completed NCT00996073 - Safety and Preliminary Efficacy Study of NeoFuse in Subjects Requiring Lumbar Interbody Fusion Phase 2
Terminated NCT00974623 - Bone Graft Materials Observational Registry N/A
Completed NCT00758719 - Evaluate Effectiveness of the Biomet Lumbar Spinal Fusion System
Completed NCT00165893 - Comparison of IDD Therapy and Non-surgical Treatment for Low Back Pain Caused by Degenerative Disc Disease Phase 4
Terminated NCT01494493 - Pivotal Study of rhBMP-2/ACS/Allograft Bone Dowel for Anterior Lumbar Interbody Fusion in Patients With Symptomatic Degenerative Disc Disease N/A
Recruiting NCT04727385 - Intervertebral DXM Gel Injection in Adults With Painful Lumbar Degenerative Disc Disease N/A
Completed NCT04849429 - Intra-discal Injection of Platelet-rich Plasma (PRP) Enriched With Exosomes in Chronic Low Back Pain Phase 1
Recruiting NCT04469387 - Preventive Effect of Limited Decompression on Adjacent Segment Following Posterior Lumbar Interbody Fusion N/A
Recruiting NCT04056520 - Clinical and Radiological Outcomes of Posterior Cervical Fusion With Medtronic Infinity Occipitocervical-Upper Thoracic (OCT) System
Completed NCT04119466 - Stabilizing Training in Degenerative Disc Disease N/A