After-each-case Room Disinfection Clinical Trial
Official title:
The Efficacy Comparing Daily and After-each-case Room Disinfection in the Endoscopy Unit During the COVID-19 Pandemic.
The aim of our study was to evaluate the difference of effectiveness between daily and after-each-case room disinfection in the endoscopy unit during the COVID-19 pandemic.
This study divided into 2 groups: daily room disinfection and after-each-case room
disinfection. Each group was also subdivided into general anesthesia or non-general
anesthesia gastroscopy, and with or without ventilation consultation room.
Samples collection include: operation unit air (six-stage sieve percussion air sampler for
sampling, airflow rate 28.3L/min, sampling time 4 min); workstation's mouse (wiping sterile
cotton for sampling); endoscopist's gown, control panel buttons, and patient's bed headboard
(contact plate for sampling).
;