Clinical Trials Logo

Clinical Trial Summary

The use of rubber dam when performing adhesive restorations improves the quality of the treatment. The widespread use of this type of restorations makes it increasingly necessary to use this type of isolation of the operative field. At the same time, the use of CAD/CAM systems in dentistry has recently become more widespread, which means that chairside systems are being used more and more frequently. Given that in indirect restorations it is necessary to place the rubber dam at the time of cementation, it has been proposed to take optical impressions of the preparation with the rubber dam already in place. For this it is necessary to have previous records that are cut out and rescanned. Since there are authors who have described that rescanning can cause defects in the meshes, in this work we try to compare both types of scanning in a specific type of restorations, the overlays. For this purpose, scans of the tooth preparation with and without rubber dam are taken, and a random decision is made on the basis of which scan the restoration is made. Then it is taken to the mouth and the marginal fit, contact points and occlusion of the restoration are evaluated. The results of the group made from the scan without dam are compared with those of the group made from the scan with dam. The two scans of each case are also compared to evaluate the differences.


Clinical Trial Description

1. Introduction: The use of rubber dam in restorative dentistry is important in order to improve the quality of restorations. The incorporation of CAD/CAD systems has led to an increase in the use of chairside techniques. In this work we intend to study in vivo to what extent the optical impressions obtained with rubber dam are equivalent to those taken without rubber dam. For better standardization, overlay restorations are studied. 2. Aims: To compare overlay restorations obtained from a scan with rubber dam placed versus restorations of the same type obtained with a scan without rubber dam. 3. Material and methods: (a) Number of patients to be treated: 30. b) Number of visits per patient: 1 c) Brief description of the different techniques used in the study, authorized and validated in the literature (3-5 lines). The use of overlay restorations is widely validated in the literature. In the digital era, rubber dam and non-rubber dam impressions are described in the literature and are used interchangeably. As there is no clinical evidence that both techniques have the same clinical efficacy, we decided to perform this in vivo comparison study. d) Benefits and harms for the patient of participating in the study (3-5 lines). Participation in the study does not involve any harm to the patient. It is all performed in the same working time, with identical materials and identical clinical technique. It does not bring any particular benefit to the patient. It is explained to the patient that his/her participation contributes to the improvement of scientific knowledge without physical, economic or material cost. e) Alternative treatment in case the patient does not wish to participate in the clinical study (3-5 lines). The same treatment is given whether the patient participates or not. The patient is informed that an overlay is required, the possible complications of this treatment are explained to him/her, and if he/she accepts, he/she is asked if he/she would object to participate in the study. Participation involves consenting to the analysis of the scans and the final evaluation of the restoration. f) Treatment to be carried out in the event of complications arising in the patient, once the clinical study has begun (3-5 lines). The clinical study is performed in a single visit and is independent of possible complications of the restoration or the tooth. g) Material necessary to carry out the study (3-5 lines). Intraoral anesthesia, milling burs, a Primescan intraoral scanner, rubber dam, W8A clamp, two-step adhesive, 5% hydrofluoric acid, silane, clamp holder, dam drill, glycerin are required. No specific material is required for the study with respect to that required for a patient who does not wish to participate in the study. 4. Evaluation of experimental and statistical results (3 lines). The sample was calculated by means of G power 3 version 3.1.9 software, 80% power and alpha=0.05. A sample of 30 was determined. The Kappa index will be used to evaluate the concordance between the two evaluators, interpreting the results with the Landis and Koch concordance table. Pearson's test will be used to evaluate the fit, occlusal contacts, interproximal contact points and choice of the best impression. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05735509
Study type Interventional
Source Universitat Internacional de Catalunya
Contact
Status Completed
Phase N/A
Start date January 30, 2023
Completion date March 5, 2023

See also
  Status Clinical Trial Phase
Active, not recruiting NCT05471024 - Occlusal Adjustment Time and Volume for Single Unit Fixed Prosthesis Fabricated With Different Virtual Mounting N/A
Terminated NCT03283709 - Removable Partial Denture Abutments Restored With Monolithic Zirconia Crowns N/A