Official title:
A Study to Evaluate Air Leak Detection Above the Endotracheal Cuff in Intubated Patients Using the AnapnoGuard 100 System
This trial is designed to assess the effectiveness of the AnapnoGaurd 100 system relative to
standard of care (SOC) Control, in the course of mechanical ventilation and intubation. The
main effectiveness aspect of this trial is the AnapnoGaurd 100's ability to reduce leaks
between the endotracheal tube and the trachea walls as a result of the cuff pressure
management. Since the primary outcome can't be measured by any method other than the
investigational device, the study groups will be treated as follows:
- The Treatment group in this study will be treated with the fully functional AnapnoGaurd
100 device (per its intended use),
- The Control group will be treated with the AnapnoGuard device, where the cuff control
will be disabled (off) and the cuff management will be done according to SOC.
Effectiveness will be measured by the duration and level of carbon dioxide (CO2) leakage
around the endotracheal tube (ETT) cuff, from the lungs to the subglottic space and safety
will be measured by adverse events (AEs).
n/a
Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Parallel Assignment, Masking: Single Blind (Subject), Primary Purpose: Prevention
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05114551 -
ICU Predictive Score of WEaning Success in Patients At Risk of Extubation Failure
|
||
Completed |
NCT05547646 -
The Prevalence of Healthcare-associated Infection in Medical Intensive Care Units in Tunisia
|
||
Recruiting |
NCT03697785 -
Weaning Algorithm for Mechanical VEntilation
|
N/A | |
Completed |
NCT02922101 -
Evaluation of the Effectiveness of an Audit and Feedback Intervention With Quality Improvement Toolbox in Intensive Care
|
N/A | |
Completed |
NCT02902783 -
DONATE-Pilot Study on ICU Management of Deceased Organ Donors
|
||
Completed |
NCT01885442 -
TryCYCLE: A Pilot Study of Early In-bed Leg Cycle Ergometry in Mechanically Ventilated Patients
|
N/A | |
Recruiting |
NCT05518955 -
VR Integrated Into Multicomponent Interventions for Improving Sleep in ICU
|
N/A | |
Recruiting |
NCT03810768 -
Metabolomics Study on Postoperative Intensive Care Acquired Muscle Weakness
|
||
Completed |
NCT03295630 -
Validity of an Actigraph Accelerometer Following Critical Illness
|
N/A | |
Completed |
NCT05556811 -
HEaling LIght Algorithms for the ICU Patient
|
N/A | |
Recruiting |
NCT05702411 -
Air Stacking Technique For Pulmonary Reexpansion
|
N/A | |
Completed |
NCT02741453 -
Bilateral Internal Jugular Veins Ultrasound Scanning Prior to CVC Placement
|
N/A | |
Recruiting |
NCT04979897 -
Impact on Mental, Physical, And Cognitive Functioning of a Critical Care sTay During the COVID-19 Pandemic
|
||
Completed |
NCT05281224 -
Ventilator Tube Holder for Patients With a Tracheostomy
|
||
Withdrawn |
NCT02970903 -
VitalPAD: an Intelligent Monitoring and Communication Device to Optimize Safety in the PICU
|
N/A | |
Recruiting |
NCT02587273 -
The Pharmacokinetics of Fentanyl in Intensive Care Patients
|
Phase 4 | |
Completed |
NCT02661607 -
Point of Care Echocardiography Versus Chest Radiography for the Assessment of Central Venous Catheter Placement
|
N/A | |
Completed |
NCT01479153 -
Venous Site for Central Catheterization
|
N/A | |
Recruiting |
NCT06110390 -
High-flow Nasal Oxygen Therapy to Prevent Extubation Failure in Adult Trauma Intensive Care Patients
|
N/A | |
Not yet recruiting |
NCT05593380 -
The Effect of BIA Monitoring of Brain Edema on the Neurological Prognosis of Supratentorial Massive ICH
|
N/A |