View clinical trials related to Coronary Restenosis.
Filter by:Prospective, open-labeled First in Man Clinical Investigation enrolling patients with visually estimated nominal vessel diameter of 3.0 mm receiving a single 3.0 x 12 mm or 3.0 x 18 mm BVS EECSS containing 98 microgramme per cm² of surface area.
The objective of this study is to evaluate the safety and effectiveness of the TAXUS Express2 Paclitaxel-Eluting Coronary Stent System as compared to brachytherapy in patients experiencing in-stent restenosis.
The process of re-narrowing of a coronary artery following a revascularization procedure such as angioplasty, begins at the time of the procedure. Restenosis has long been considered a major problem for effective long-term interventional success. This often results in repeated procedures to deal with recurrent stenosis (or restenosis) of the original targeted vessel. There is a substantial body of literature suggesting that local MYC protein production in the injured coronary artery is a major stimulus and potential cause of restenosis that appears after stent placement. This study is based upon the hypothesis that stopping MYC protein production in the vessel will help reduce restenosis (vessel re-narrowing). AVI BioPharma Inc., has utilized its proprietary antisense chemistry to design a drug that interferes with MYC production. This study will evaluate the safety and potential effectiveness of RESTEN-MP to reduce in-stent restenosis following balloon angioplasty and stent placement. The post-dose follow-up period is up to six-months. RESTEN-MP is administered at the time a stent is successfully placed in a coronary artery, and again 24 hours later, via slow-push intravenous administration.
This study is divided into 5 arms: 1. Randomized Clinical Trial (RCT): Prospective, randomized, active-controlled, single blind, parallel two-arm multi-center clinical trial in the United States (US) comparing XIENCE V® Everolimus Eluting Coronary Stent System (CSS) (2.5, 3.0, 3.5 mm diameter stents) to the Food and Drug Administration (FDA) approved commercially available active control TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent (TAXUS® EXPRESS2™ PECS) System 2. US 2.25 mm non-randomized arm using 2.25 mm diameter XIENCE V® Everolimus Eluting CSS 3. US 4.0 mm non-randomized arm using 4.0 mm diameter XIENCE V® Everolimus Eluting CSS 4. US 38 mm non-randomized arm using 38 mm in length XIENCE V® Everolimus Eluting CSS 5. Japanese non-randomized arm using XIENCE V® Everolimus Eluting CSS (2.5, 3.0, 3.5, 4.0 mm diameter stents) in Japan The TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent System is Manufactured by Boston Scientific.
PROSPECT is a multi-center prospective registry of Acute Coronary Syndromes (ACS) patients with single or double vessel coronary artery disease. Approximately 700 patients with ACS will be enrolled into the study at sites in the United States and European Union.
Prospective, randomized, active-control, single blind, parallel two-arm multi-center clinical trial comparing XIENCE V® Everolimus Eluting Coronary Stent System to the approved commercially available active control TAXUS™ EXPRESS2™ Paclitaxel Eluting Coronary Stent System. TAXUS™ EXPRESS2™ Paclitaxel Eluting Coronary Stent System is manufactured by Boston Scientific.
The purpose of this clinical research study is determine if patients with diabetes that have undergone previous opening of a heart blockage may have a blockage that is not causing any symptoms that may be detected by imaging with Cardiolite.
The purpose of this study is to demonstrate the safety and efficacy of the ZoMaxx drug-eluting stent in patients with blockage of native coronary arteries. The study is designed to demonstrate non-inferiority to the TAXUS Express2 Paclitaxel-Eluting Stent that has proven superior to bare metal stents and is a recognized standard of care.
The purpose of this study is to demonstrate the safety and efficacy of the ZoMaxx drug-eluting stent in patients with blockage of native coronary arteries. The study is designed to demonstrate non-inferiority to the TAXUS Express2 Paclitaxel-Eluting Stent that has proven superior to bare metal stents and is a recognized standard of care.
The purpose of this study was to investigate the use of systemic intracoronary administration of albumin-bound paclitaxel, ABI-007, for the prevention and reduction of restenosis following de novo stenting or following angioplasty for in-stent restenosis.