View clinical trials related to Coronary Occlusion.
Filter by:Under the circumstances that appropriate first-choice guidewires for percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) have yet to be established, the objective of this study is to determine appropriate first-choice guidewires. G-FORCE study is a prospective multicenter randomized study between normal (distal tip size 0.014 inch) and slender (distal tip size 0.010 inch or less) guidewires. Primary end point is lesion penetration rate of the first choice guidewire.
Chronic total coronary occlusions (CTO) have an especially high risk of angiographic restenosis, and need for new revascularization procedures. Drug-eluting coronary stents (DES) have demonstrated to significantly reduce the risk of restenosis and new revascularization procedures in comparison with bare-metal stents. Most data on the efficacy of DES come from the sirolimus-eluting coronary stent Cypher (Cordis corp.), and paclitaxel-eluting coronary stent Taxus (Boston Sci.), and the Cypher stent is the only DES that has been randomly tested in CTO. Among second-generation DES, everolimus-eluting stent (EES) has shown excellent angiographic and clinical results, but this DES has not been studied in unfavourable scenario (such as CTO). The aim of the CIBELES trial is to demonstrate the hypothesis that EES are equally effective in comparison with sirolimus-eluting stents in the treatment of CTO, in terms of angiographic efficacy considered as in-stent late lumen loss.
A prospective, randomized multicenter study of subjects with a high-risk of having a myocardial infarction (MI) due to acute coronary syndrome or bypass surgery. There is no differential intervention administered to the two arms of the ALERTS Study. The study evaluates whether or not a patient alarm from the Guardian System will provide benefit (e.g. shorten pre-hospital delay) compared to symptoms-only ER presentation in the event of a heart attack. An amendment to the data analysis protocol was collaboratively created by AngelMed and FDA, and was adopted by AngelMed on 4/22/2017.
The purpose of the study is the evaluation of multiple biomarkers related to acute coronary syndromes, including myeloid-related protein 8/14 (MRP 8/14), along with established clinical markers, for early diagnosis and risk stratification in patients presenting with acute chest pain at the emergency department. Study hypothesis: MRP 8/14, alone or together with other established or new biomarkers, increases the earliness, sensitivity, and specificity of diagnosing acute coronary syndromes.
The ACIC is a Collaborative Quality Improvement (CQI) program involving the collection of data related to: indications for Coronary Computed Tomography (CCTA), patient health characteristics, acquisition techniques of CCTA scans, physician interpretation of results and short-term outcomes over a 90 day period.
The CiTop™ guidewire Coronary study is a feasibility open label study, to evaluate the safety and efficacy of the CiTop™ Guidewire for crossing chronic total occlusion in Coronary arteries.
The purpose of this Clinical Evaluation is the continued assessment of the XIENCE Everolimus Eluting Coronary Stent System (XIENCE V® and XIENCE PRIME™ EECSS) with the primary focus on clinical outcomes in the treatment of female patients with de novo coronary artery lesions, and the characterization of the female population undergoing stent implantation with a XIENCE stent.
The test compound and subject of this clinical trial is the haemoglobin-based oxygen carrier, HBOC-201 (Hemopure). HBOC-201, initially developed as an alternative to red blood cells for surgical patients, has the ability to restore tissue oxygenation in persistently ischemic tissue. The development of this new class of compounds, referred to as oxygen therapeutics, provides an opportunity to test the safety and efficacy of a new approach to management of myocardial ischemia.
Primary intracoronary stent placement after successfully crossing chronic total coronary occlusions (CTO) decreases the high restenosis rate at long-term follow-up compared with conventional balloon angioplasty. Several studies have shown the efficacy of sirolimus-eluting stents in selected groups of patients. In the PRISON II study we demonstrated that sirolimus-eluting stents were superior to bare metal stents in CTO. In this prospective randomized trial, sirolimus-stent implantation will be compared with zotarolimus-eluting stent implantation for the treatment of chronic total coronary occlusions. A total of 300 patients will be clinically followed up for 1, 6, 12 months, 2, 3, 4, 5 year with angiographic follow-up at 8 months. Quantitative coronary analysis will be performed by an independent core laboratory. The primary end point is in-segment late luminal loss at 8 month angiographic follow-up.
ACROSS-Cypher® is a prospective, multi-center, open label, single arm study of the Cypher® sirolimus eluting coronary stent in native total coronary occlusion revascularization. The primary endpoint is binary angiographic restenosis at 6 months. The TOSCA-1 trial will be used as the historical control. The hypothesis is that compared with TOSCA-1 patients who were treated with the heparin-coated Palmaz Schatz stent, treatment with the Cypher® sirolimus eluting coronary stent will result in a >50% relative reduction in 6 month restenosis within the treated segment of the target vessel.