Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT02658045
Other study ID # 0172-15MMC
Secondary ID
Status Not yet recruiting
Phase Phase 1
First received December 2, 2015
Last updated January 14, 2016
Start date February 2016
Est. completion date December 2016

Study information

Verified date November 2015
Source Meir Medical Center
Contact Alex - Guber, MD
Phone +972-522-496934
Email Alexgu@clalit.org.il
Is FDA regulated No
Health authority Israel: Ministry of Health
Study type Observational

Clinical Trial Summary

The trial shall assess the accuracy of the Oxitone® 1000 in measuring oxygen saturation, by comparing its measurement to reference devices: non-invasive SpO2 and pulse-rate values determined by a pulse oximeter. A total of approximately 40 subjects: 20 healthy and 20 COPD (chronic obstructive pulmonary disease ) patients will be enrolled. These subjects will be enrolled at the medical center pulmonary department and will be recruited from the clinic patient base. The subjects will be represented by male and female adults who optimally cover a range of ethnic backgrounds (skin pigmentation). All testing will be performed in singleton and in a blinded fashion. This study will be conducted with the approval of the medical center ethics committee.

This is a comparison open study with no subject follow-up.


Description:

The Oxitone® 1000 oximetry readings are accurate and measure with an acceptable relative absolute difference (RAD) when compared to accepted measurement systems (FDA recognized predicate) the "Reference".

The objectives:

1. To validate the Oxitone® 1000 performance in continuous or spot oximetry monitoring, relative to Reference readings.

2. To aggregate longitudinal clinical data from COPD patients measuring SpO2, pulse rate and activity.

3. To evaluate the main device parameters and characteristics such as sensor placement tolerance, device accuracy, precision, convenience and easy-to-use at stationary supine or seated tests and at mild motions as well.

4. To determine whether the measured data provided from patients (SpO2, pulse rate and movement) is useful in adjusting their treatment protocol.

5. To assess the safety and tolerability (compliance) of the Oxitone® 1000 in continuous oximetry monitoring in order to obtain sufficient clinical trial data in order to define performance criteria of the device system that are acceptable / useful in the medical context for patient populations and other healthy individuals, in which the device is likely to be used.

Overview: The trial shall assess the accuracy of the Oxitone® 1000 in measuring oxygen saturation, by comparing its measurement to reference devices: non-invasive SpO2 and pulse-rate values determined by a pulse oximeter. A total of approximately 40 subjects (20 healthy and 20 COPD patients) will be enrolled. These subjects will be enrolled at the medical center pulmonary department and will be recruited from the clinic patient base. The subjects will be represented by male and female adults who optimally cover a range of ethnic backgrounds (skin pigmentation). All testing will be performed in singleton and in a blinded fashion. This study will be conducted with the approval of the medical center ethics committee.This is a comparison open study with no subject follow-up.

Procedure: All instruments will be checked for functionality and battery operational capacity, prior to subject attachment including the data collection system, i.e. the wireless (B.T.) connectivity to P.C. (synchronized bidirectional two channels).

The "Reference" oximeter device shall be set for averaging mode of 12 seconds. Two sensors will be placed simultaneously on the subjects: A standard SpO2 (reference) will be placed on the subject's index finger and the tested Oxitone® 1000 will be placed on the subject's wrist of the same hand.

Methods:: The investigators are to study approximately 40 subjects, both normal, i.e. comparison group and patients with a variety of pulmonary conditions that effect oxygen saturation. The investigators will compare the oxygen saturation of each subject as measured with Oxitone® 1000 device and with the oxygen saturation as measured with calibrated conventional FDA approved pulse oximeter (predicate). The "Reference". No treatment decision will be made utilizing the results of the tested device.

Trial design:

A. Healthy subjects: Spot-check measurements of 20 healthy volunteers simultaneously tested by using Oxitone oximeter and standard fingertip pulse oximeter at stationary state i.e. at sitting and standing positions up to 6 minutes each.

1. A 6-minute.walk: oximetry tests of 20 healthy volunteers simultaneously tested using Oxitone oximeter and standard fingertip pulse oximeter in accordance with the industry (Medical) standards of 6-min walk protocol. Measurements are collected and recorded continuously prior to test, during the test and after 6 minutes the test. The distance of the 6-min walk will be recorded (CRF).

B. COPD (Chronic obstructive pulmonary disease) subjects

1. Spot-check measurements up to 20 ambulatory COPD patients. Patients should be referred and admitted to the pulmonary lab for clinical treatment or should be under the rehabilitation procedures. Measurements will be made simultaneously using Oxitone® oximeter and while standard fingertip pulse oximeter stationary state at e.g. supine or dorsal elevated sitting, and while standing (upright) positions up to 6 min each.

2. A 6-min walk oximetry tests of ambulatory COPD patients. Patients should be referred to the pulmonary lab for clinical purposes or should be under the rehabilitation procedures. The measurements are taken using Oxitone® oximeter and standard fingertip pulse oximeter in accordance with the standard protocol. Measurements are taken continuously prior to the test, during the test and 1 minute after the test, at rest. The distance of the 6-min walk will be recorded. Rehabilitation subjects procedures. The measurements are taken using Oxitone® Oximeter and standard fingertip pulse oximeter in accordance with the standard protocol. Measurements are taken continuously prior to the test. The distance of the 6-min walk will be recorded.


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 40
Est. completion date December 2016
Est. primary completion date December 2016
Accepts healthy volunteers Accepts Healthy Volunteers
Gender Both
Age group 18 Years to 80 Years
Eligibility Inclusion Criteria:

- Pulmonary sick and healthy male and female volunteers aged 18 years and over (any race or ethnicity).

- Subjects who are willing to give informed consent.

- No precautions are required: this study involves no known additional risk to the subjects.

Exclusion Criteria:

- Participants under the age of 18 years

- Significant deformity, degenerative changes or edema of the hand wrist

- Localized infection, ulceration or skin breaks involving the wrist

- Vascular disease or Raynaud's phenomenon affecting the hand

- Participants who are unable to give informed written consent

- Anemia: Hb < 10.0 g/dl

Study Design

Observational Model: Cohort, Time Perspective: Prospective


Related Conditions & MeSH terms


Intervention

Device:
Standard Oximeter
Oxygen saturation will be measured by standard oximeter
Oxitone oximeter
Oxygen saturation will be measured by Oxitone oximeter

Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
Meir Medical Center

References & Publications (3)

Hornberger C, Matz H, Konecny E, Frankenberger H, Bonk R, Avgerinos J, Benekos K, Valais J, Ikiades A, Gil-Rodriguez J, Wouters P, Meyfroidt G, Ponz L, Gehring H. Design and validation of a pulse oximeter calibrator. Anesth Analg. 2002 Jan;94(1 Suppl):S8-12. — View Citation

Mendelson Y. Pulse oximetry: theory and applications for noninvasive monitoring. Clin Chem. 1992 Sep;38(9):1601-7. Review. — View Citation

Trivedi NS, Ghouri AF, Shah NK, Lai E, Barker SJ. Effects of motion, ambient light, and hypoperfusion on pulse oximeter function. J Clin Anesth. 1997 May;9(3):179-83. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary change in oxygen saturation from baseline to six minute walk Oxygen saturation is measured with standard oximeter and Oxitone oximeter Baseline and after six minute walk No
See also
  Status Clinical Trial Phase
Active, not recruiting NCT06000696 - Healthy at Home Pilot
Active, not recruiting NCT03927820 - A Pharmacist-Led Intervention to Increase Inhaler Access and Reduce Hospital Readmissions (PILLAR) N/A
Completed NCT04043728 - Addressing Psychological Risk Factors Underlying Smoking Persistence in COPD Patients: The Fresh Start Study N/A
Completed NCT04105075 - COPD in Obese Patients
Recruiting NCT05825261 - Exploring Novel Biomarkers for Emphysema Detection
Active, not recruiting NCT04075331 - Mepolizumab for COPD Hospital Eosinophilic Admissions Pragmatic Trial Phase 2/Phase 3
Terminated NCT03640260 - Respiratory Regulation With Biofeedback in COPD N/A
Recruiting NCT04872309 - MUlti-nuclear MR Imaging Investigation of Respiratory Disease-associated CHanges in Lung Physiology
Recruiting NCT05145894 - Differentiation of Asthma/COPD Exacerbation and Stable State Using Automated Lung Sound Analysis With LungPass Device
Withdrawn NCT04210050 - Sleep Ventilation for Patients With Advanced Hypercapnic COPD N/A
Terminated NCT03284203 - Feasibility of At-Home Handheld Spirometry N/A
Recruiting NCT06110403 - Impact of Long-acting Bronchodilator- -Corticoid Inhaled Therapy on Ventilation, Lung Function and Breathlessness Phase 1/Phase 2
Active, not recruiting NCT06040424 - Comparison of Ipratropium / Levosalbutamol Fixed Dose Combination and Ipratropium and Levosalbutamol Free Dose Combination in pMDI Form in Stable Chronic Obstructive Pulmonary Disease (COPD) Patients Phase 3
Recruiting NCT05865184 - Evaluation of Home-based Sensor System to Detect Health Decompensation in Elderly Patients With History of CHF or COPD
Recruiting NCT04868357 - Hypnosis for the Management of Anxiety and Breathlessness During a Pulmonary Rehabilitation Program N/A
Completed NCT01892566 - Using Mobile Health to Respond Early to Acute Exacerbations of COPD in HIV N/A
Completed NCT04119856 - Outgoing Lung Team - a Cross-sectorial Intervention in Patients With COPD N/A
Completed NCT04485741 - Strados System at Center of Excellence
Completed NCT03626519 - Effects of Menthol on Dyspnoea in COPD Patients N/A
Recruiting NCT04860375 - Multidisciplinary Management of Severe COPD N/A